메뉴 건너뛰기




Volumn 26, Issue 1, 2010, Pages 39-55

Optimisation-based thermal treatment planning for catheter-based ultrasound hyperthermia

Author keywords

Finite element modelling; Hyperthermia; Optimisation; Treatment planning; Ultrasound

Indexed keywords

ARTICLE; BRACHYTHERAPY; CATHETER; HUMAN; HYPERTHERMIC THERAPY; IMPLANT; INTERSTITIUM; TEMPERATURE SENSITIVITY; THERMAL EXPOSURE; TRANSDUCER; TREATMENT PLANNING; ULTRASOUND; UTERINE CERVIX;

EID: 76149096868     PISSN: 02656736     EISSN: 14645157     Source Type: Journal    
DOI: 10.3109/02656730903341332     Document Type: Article
Times cited : (44)

References (64)
  • 1
    • 0035070587 scopus 로고    scopus 로고
    • Hyperthermic radiosensitization: Mode of action and clinical relevance
    • Kampinga HH, Dikomey E. Hyperthermic radiosensitization: Mode of action and clinical relevance. Int J Radiat Biol 2001;77:399-408.
    • (2001) Int J Radiat Biol , vol.77 , pp. 399-408
    • Kampinga, H.H.1    Dikomey, E.2
  • 2
    • 0036668656 scopus 로고    scopus 로고
    • Heating the patient: A promising approach?
    • van der Zee J. Heating the patient: A promising approach? Ann Oncol 2002;13:1173-1184.
    • (2002) Ann Oncol , vol.13 , pp. 1173-1184
    • Van Der Zee, J.1
  • 6
    • 0033302717 scopus 로고    scopus 로고
    • Engineering aspects of hyperthermia therapy
    • Roemer RB. Engineering aspects of hyperthermia therapy. Annu Rev Biomed Eng 1999;1:347-376.
    • (1999) Annu Rev Biomed Eng , vol.1 , pp. 347-376
    • Roemer, R.B.1
  • 7
    • 0030290647 scopus 로고    scopus 로고
    • Transurethral ultrasound array for prostate thermal therapy: Initial studies
    • Diederich CJ, Burdette EC. Transurethral ultrasound array for prostate thermal therapy: Initial studies. IEEE Trans Ultrason Ferroelec Freq Control 1996;43:1011-1022.
    • (1996) IEEE Trans Ultrason Ferroelec Freq Control , vol.43 , pp. 1011-1022
    • Diederich, C.J.1    Burdette, E.C.2
  • 8
    • 0029979953 scopus 로고    scopus 로고
    • Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: A feasibility study
    • Diederich CJ, Khalil IS, Stauffer PR, Sneed PK, Phillips TL. Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: A feasibility study. Int J Hyperthermia 1996;12:401-419.
    • (1996) Int J Hyperthermia , vol.12 , pp. 401-419
    • Diederich, C.J.1    Khalil, I.S.2    Stauffer, P.R.3    Sneed, P.K.4    Phillips, T.L.5
  • 9
    • 0029926289 scopus 로고    scopus 로고
    • Ultrasound applicators with integrated cathetercooling for interstitial hyperthermia: Theory and preliminary experiments
    • Diederich CJ. Ultrasound applicators with integrated cathetercooling for interstitial hyperthermia: Theory and preliminary experiments. Int J Hyperthermia 1996;12:279-297.
    • (1996) Int J Hyperthermia , vol.12 , pp. 279-297
    • Diederich, C.J.1
  • 10
    • 33646455470 scopus 로고    scopus 로고
    • Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy
    • Kinsey AM, Diederich CJ, Tyreus PD, Nau WH, Rieke V, Pauly KB. Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy. Med Phys 2006;33:1352-1363.
    • (2006) Med Phys , vol.33 , pp. 1352-1363
    • Kinsey, A.M.1    Diederich, C.J.2    Tyreus, P.D.3    Nau, W.H.4    Rieke, V.5    Pauly, K.B.6
  • 11
    • 0034078121 scopus 로고    scopus 로고
    • Directional power deposition from direct-coupled and catheter-cooled interstitial ultrasound applicators
    • Nau WH, Diederich CJ, Stauffer PR. Directional power deposition from direct-coupled and catheter-cooled interstitial ultrasound applicators. Int J Hyperthermia 2000;16:129-144.
    • (2000) Int J Hyperthermia , vol.16 , pp. 129-144
    • Nau, W.H.1    Diederich, C.J.2    Stauffer, P.R.3
  • 13
    • 0033031096 scopus 로고    scopus 로고
    • Spatial steering with quadruple electrodes in 27MHz capacitively coupled interstitial hyperthermia
    • Crezee J, Kaatee RS, van der Koijk JF, Lagendijk JJ. Spatial steering with quadruple electrodes in 27MHz capacitively coupled interstitial hyperthermia. Int J Hyperthermia 1999; 15:145-156.
    • (1999) Int J Hyperthermia , vol.15 , pp. 145-156
    • Crezee, J.1    Kaatee, R.S.2    Van Der Koijk, J.F.3    Lagendijk, J.J.4
  • 15
    • 0034083356 scopus 로고    scopus 로고
    • Hyperthermia treatment planning
    • Lagendijk JJ. Hyperthermia treatment planning. Phys Med Biol 2000;45:R61-R76.
    • (2000) Phys Med Biol , vol.45
    • Lagendijk, J.J.1
  • 19
    • 18544364308 scopus 로고    scopus 로고
    • Optimal procedure for thermal delivery in hyperthermic/chemotherapeutic treatments in the isolated perfusion of the limbs
    • Pace M, Millanta L, Polignano M, Gattai R, Macera Mascitelli E. Optimal procedure for thermal delivery in hyperthermic/chemotherapeutic treatments in the isolated perfusion of the limbs. J Exp Clin Cancer Res 2005;24:35-42.
    • (2005) J Exp Clin Cancer Res , vol.24 , pp. 35-42
    • Pace, M.1    Millanta, L.2    Polignano, M.3    Gattai, R.4    MacEra Mascitelli, E.5
  • 23
    • 34249012828 scopus 로고    scopus 로고
    • Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method
    • de Bruijne M, Samaras T, Chavannes N, van Rhoon GC. Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method. Phys Med Biol 2007;52: 3075-3088.
    • (2007) Phys Med Biol , vol.52 , pp. 3075-3088
    • De Bruijne, M.1    Samaras, T.2    Chavannes, N.3    Van Rhoon, G.C.4
  • 24
    • 41049090670 scopus 로고    scopus 로고
    • Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of 'virtual sources'
    • Cheng KS, Stakhursky V, Craciunescu OI, Stauffer P, Dewhirst M, Das SK. Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of 'virtual sources'. Phys Med Biol 2008;53:1619-1635.
    • (2008) Phys Med Biol , vol.53 , pp. 1619-1635
    • Cheng, K.S.1    Stakhursky, V.2    Craciunescu, O.I.3    Stauffer, P.4    Dewhirst, M.5    Das, S.K.6
  • 26
    • 0034083356 scopus 로고    scopus 로고
    • Hyperthermia treatment planning
    • Lagendijk JJ. Hyperthermia treatment planning. Phys Med Biol 2000;45:R61-R76.
    • (2000) Phys Med Biol , vol.45
    • Lagendijk, J.J.1
  • 28
    • 0029744989 scopus 로고    scopus 로고
    • Simulation studies promote technological development of radiofrequency phased array hyperthermia
    • Wust P, Seebass M, Nadobny J, Deuflhard P, Monich G, Felix R. Simulation studies promote technological development of radiofrequency phased array hyperthermia. Int J Hyperthermia 1996;12:477-494.
    • (1996) Int J Hyperthermia , vol.12 , pp. 477-494
    • Wust, P.1    Seebass, M.2    Nadobny, J.3    Deuflhard, P.4    Monich, G.5    Felix, R.6
  • 30
    • 9744273095 scopus 로고    scopus 로고
    • Optimization of the sources in local hyperthermia using a combined finite element-genetic algorithm method
    • Siauve N, Nicolas L, Vollaire C, Marchal C. Optimization of the sources in local hyperthermia using a combined finite element-genetic algorithm method. Int J Hyperthermia 2004; 20:815-833.
    • (2004) Int J Hyperthermia , vol.20 , pp. 815-833
    • Siauve, N.1    Nicolas, L.2    Vollaire, C.3    Marchal, C.4
  • 31
    • 34249844037 scopus 로고    scopus 로고
    • Delineation of potential hot spots for hyperthermia treatment planning optimisation
    • Wiersma J, van Wieringen N, Crezee H, van Dijk JD. Delineation of potential hot spots for hyperthermia treatment planning optimisation. Int J Hyperthermia 2007;23:287-301.
    • (2007) Int J Hyperthermia , vol.23 , pp. 287-301
    • Wiersma, J.1    Van Wieringen, N.2    Crezee, H.3    Van Dijk, J.D.4
  • 32
    • 0032902780 scopus 로고    scopus 로고
    • Optimization of pelvic heating rate distributions with electromagnetic phased arrays
    • Paulsen KD, Geimer S, Tang J, Boyse WE. Optimization of pelvic heating rate distributions with electromagnetic phased arrays. Int J Hyperthermia 1999;15:157-186.
    • (1999) Int J Hyperthermia , vol.15 , pp. 157-186
    • Paulsen, K.D.1    Geimer, S.2    Tang, J.3    Boyse, W.E.4
  • 33
    • 0036846223 scopus 로고    scopus 로고
    • Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimation
    • Kowalski ME, Behnia B, Webb AG, Jin JM. Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimation. IEEE Trans Biomed Eng 2002;49:1229-1241.
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 1229-1241
    • Kowalski, M.E.1    Behnia, B.2    Webb, A.G.3    Jin, J.M.4
  • 34
    • 12344277610 scopus 로고    scopus 로고
    • Transient solution to the bioheat equation and optimization for magnetic fluid hyperthermia treatment
    • Bagaria HG, Johnson DT. Transient solution to the bioheat equation and optimization for magnetic fluid hyperthermia treatment. Int J Hyperthermia 2005;21:57-75.
    • (2005) Int J Hyperthermia , vol.21 , pp. 57-75
    • Bagaria, H.G.1    Johnson, D.T.2
  • 35
    • 0031849330 scopus 로고    scopus 로고
    • Minimax optimization-based inverse treatment planning for interstitial thermal therapy
    • Khalil-Bustany IS, Diederich CJ, Polak E, Kirjner-Neto C. Minimax optimization-based inverse treatment planning for interstitial thermal therapy. Int J Hyperthermia 1998;14: 347-366.
    • (1998) Int J Hyperthermia , vol.14 , pp. 347-366
    • Khalil-Bustany, I.S.1    Diederich, C.J.2    Polak, E.3    Kirjner-Neto, C.4
  • 36
    • 0030095959 scopus 로고    scopus 로고
    • Interstitial ultrasound applicators are practical from an engineering perspective for treating large tumours
    • Diederich CJ. Interstitial ultrasound applicators are practical from an engineering perspective for treating large tumours. Int J Hyperthermia 1996;12:305-306.
    • (1996) Int J Hyperthermia , vol.12 , pp. 305-306
    • Diederich, C.J.1
  • 37
    • 0034924770 scopus 로고    scopus 로고
    • Evaluation of multielement catheter-cooled interstitial ultrasound applicators for high-temperature thermal therapy
    • Nau WH, Diederich CJ, Burdette EC. Evaluation of multielement catheter-cooled interstitial ultrasound applicators for high-temperature thermal therapy. Med Phys 2001; 28:1525-1534.
    • (2001) Med Phys , vol.28 , pp. 1525-1534
    • Nau, W.H.1    Diederich, C.J.2    Burdette, E.C.3
  • 38
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperature in the resting human forearm
    • Pennes H. Analysis of tissue and arterial blood temperature in the resting human forearm. J Appl Physiol 1948;1:93-102.
    • (1948) J Appl Physiol , vol.1 , pp. 93-102
    • Pennes, H.1
  • 39
    • 37549059582 scopus 로고    scopus 로고
    • Prostate thermal therapy with high intensity transurethral ultrasound: The impact of pelvic bone heating on treatment delivery
    • Wootton JH, Ross AB, Diederich CJ. Prostate thermal therapy with high intensity transurethral ultrasound: The impact of pelvic bone heating on treatment delivery. Int J Hyperthermia 2007;23:609-622.
    • (2007) Int J Hyperthermia , vol.23 , pp. 609-622
    • Wootton, J.H.1    Ross, A.B.2    Diederich, C.J.3
  • 41
    • 0034316341 scopus 로고    scopus 로고
    • Experimental study of the acoustical properties of polymers utilized to construct PVDF ultrasonic transducers and the acousto-electric properties of PVDF and P(VDF/TrFE) films
    • Bloomfield PE, Lo WJ, Lewin PA. Experimental study of the acoustical properties of polymers utilized to construct PVDF ultrasonic transducers and the acousto-electric properties of PVDF and P(VDF/TrFE) films. IEEE Trans Ultrason Ferroelec Freq Control 2000;47:1397-1405.
    • (2000) IEEE Trans Ultrason Ferroelec Freq Control , vol.47 , pp. 1397-1405
    • Bloomfield, P.E.1    Lo, W.J.2    Lewin, P.A.3
  • 42
    • 0018000447 scopus 로고
    • Comprehensive compilation of empirical ultrasonic properties of mammalian tissues
    • Goss SA, Johnston RL, Dunn F. Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. J Acoust Soc Amer 1978;64:423-457.
    • (1978) J Acoust Soc Amer , vol.64 , pp. 423-457
    • Goss, S.A.1    Johnston, R.L.2    Dunn, F.3
  • 44
    • 0002851192 scopus 로고
    • Biophysics and technology of ultrasound hyperthermia
    • Gautherie M, editor. Berlin: Springer-Verlag
    • Hynynen KH. Biophysics and technology of ultrasound hyperthermia. In: Gautherie M, editor. Methods of external hyperthermic heating. Berlin: Springer-Verlag; 1990. pp 61-115.
    • (1990) Methods of External Hyperthermic Heating , pp. 61-115
    • Hynynen, K.H.1
  • 45
    • 16744363726 scopus 로고    scopus 로고
    • Effect of applicator diameter on lesion size from high temperature interstitial ultrasound thermal therapy
    • Tyreus PD, Nau WH, Diederich CJ. Effect of applicator diameter on lesion size from high temperature interstitial ultrasound thermal therapy. Med Phys 2003;30:1855-1863.
    • (2003) Med Phys , vol.30 , pp. 1855-1863
    • Tyreus, P.D.1    Nau, W.H.2    Diederich, C.J.3
  • 47
    • 34250862202 scopus 로고
    • Induction of hyperthermia using an intracavitary multielement ultrasonic applicator
    • Diederich CJ, Hynynen K. Induction of hyperthermia using an intracavitary multielement ultrasonic applicator. IEEE Trans Biomed Eng 1989;36:432-438.
    • (1989) IEEE Trans Biomed Eng , vol.36 , pp. 432-438
    • Diederich, C.J.1    Hynynen, K.2
  • 48
    • 0037035346 scopus 로고    scopus 로고
    • Theoretical model of internally cooled interstitial ultrasound applicators for thermal therapy
    • Tyreus PD, Diederich CJ. Theoretical model of internally cooled interstitial ultrasound applicators for thermal therapy. Phys Med Biol 2002;47:1073-1089.
    • (2002) Phys Med Biol , vol.47 , pp. 1073-1089
    • Tyreus, P.D.1    Diederich, C.J.2
  • 50
    • 76149124745 scopus 로고    scopus 로고
    • COMSOL. http://www.comsol.com/products/multiphysics/
  • 52
    • 76149128579 scopus 로고    scopus 로고
    • MATLAB
    • MATLAB. http://www.mathworks.com/products/optimization/ description3.html.
  • 53
    • 0028335852 scopus 로고
    • Arrhenius relationships from the molecule and cell to the clinic
    • Dewey WC. Arrhenius relationships from the molecule and cell to the clinic. Int J Hyperthermia 1994;10:457-483.
    • (1994) Int J Hyperthermia , vol.10 , pp. 457-483
    • Dewey, W.C.1
  • 54
  • 58
    • 0021177858 scopus 로고
    • Thermal dose expression in clinical hyperthermia and correlation with tumor response/control
    • Perez CA, Sapareto SA. Thermal dose expression in clinical hyperthermia and correlation with tumor response/control. Cancer Res 1984;44:4818S-4825S.
    • (1984) Cancer Res , vol.44
    • Perez, C.A.1    Sapareto, S.A.2
  • 59
    • 0036783997 scopus 로고    scopus 로고
    • Prostate perfusion in patients with locally advanced prostate carcinoma treated with different hyperthermia techniques
    • van Vulpen M, Raaymakers BW, de Leeuw AA, et al. Prostate perfusion in patients with locally advanced prostate carcinoma treated with different hyperthermia techniques. J Urol 2002;168:1597-1602.
    • (2002) J Urol , vol.168 , pp. 1597-1602
    • Van Vulpen, M.1    Raaymakers, B.W.2    De Leeuw, A.A.3
  • 63
    • 63649116596 scopus 로고    scopus 로고
    • Probabilistic finite element analysis of radiofrequency liver ablation using the unscented transform
    • Dos Santos I, Haemmerich D, Schutt D, da Rocha AF, Menezes LR. Probabilistic finite element analysis of radiofrequency liver ablation using the unscented transform. Phys Med Biol 2009;54:627-640.
    • (2009) Phys Med Biol , vol.54 , pp. 627-640
    • Dos Santos, I.1    Haemmerich, D.2    Schutt, D.3    Da Rocha, A.F.4    Menezes, L.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.