메뉴 건너뛰기




Volumn 114, Issue 8, 2009, Pages 1367-1382

Virtopsy versus digital autopsy: Virtuous autopsy;Virtopsy versus autopsia digitale: autopsia virtuosa

Author keywords

Digital autopsy; Forensic radiology; Magnetic resonance imaging (MRI); Multislice computed tomography (MSCT); Noninvasive autopsy; Postmortem imaging

Indexed keywords

ARTICLE; AUTOPSY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER INTERFACE; FEASIBILITY STUDY; FORENSIC MEDICINE; HUMAN; INSTRUMENTATION; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; THREE DIMENSIONAL IMAGING;

EID: 75949104178     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11547-009-0435-1     Document Type: Article
Times cited : (52)

References (58)
  • 1
    • 0032430378 scopus 로고    scopus 로고
    • Practice guideline for forensic pathology
    • College of American Pathologists. Arch Pathol Lab Med
    • Randall BB, Fierro MF, Froede RC (1998) Practice guideline for forensic pathology. Members of the Forensic Pathology Committee, College of American Pathologists. Arch Pathol Lab Med 122:1056-1064
    • (1998) Members of the Forensic Pathology Committee , vol.122 , pp. 1056-1064
    • Randall, B.B.1    Fierro, M.F.2    Froede, R.C.3
  • 2
    • 0021695756 scopus 로고
    • Basic principles in the investigation of homicides
    • Di Maio VJ (1984) Basic principles in the investigation of homicides. Pathol Annu 19 Pt 2:149-164
    • (1984) Pathol Annu 19 Pt , vol.2 , pp. 149-164
    • Di Maio, V.J.1
  • 3
    • 33847064974 scopus 로고    scopus 로고
    • Virtopsy - the Swiss virtual autopsy approach
    • Thali MJ, Jackowski C, Oesterhelweg L et al. (2007) Virtopsy - the Swiss virtual autopsy approach. Leg Med 9:100-104
    • (2007) Leg Med , vol.9 , pp. 100-104
    • Thali, M.J.1    Jackowski, C.2    Oesterhelweg, L.3
  • 4
    • 7544232172 scopus 로고    scopus 로고
    • Is virtual histology the next step after the virtual autopsy? Magnetic resonance microscopy in forensic medicine
    • Thali MJ, Dirnhofer R, Becker R et al. (2004) Is "virtual histology" the next step after the "virtual autopsy"? Magnetic resonance microscopy in forensic medicine. Magn Reson Imaging 22:1131-1138
    • (2004) Magn Reson Imaging , vol.22 , pp. 1131-1138
    • Thali, M.J.1    Dirnhofer, R.2    Becker, R.3
  • 5
    • 0037373187 scopus 로고    scopus 로고
    • New horizons in forensic radiology: The 60-second digital autopsy-full-body examination of a gunshot victim by multislice computed tomography
    • Thali MJ, Schweitzer W, Yen K et al. (2003) New horizons in forensic radiology: the 60-second digital autopsy-full-body examination of a gunshot victim by multislice computed tomography. Am J Forensic Med Pathol 24:22-27
    • (2003) Am J Forensic Med Pathol , vol.24 , pp. 22-27
    • Thali, M.J.1    Schweitzer, W.2    Yen, K.3
  • 6
    • 0038309925 scopus 로고    scopus 로고
    • Into the decomposed bodyforensic digital autopsy using multislice-computed tomography
    • Thali MJ, Yen K, Schweitzer W et al. (2003) Into the decomposed bodyforensic digital autopsy using multislice-computed tomography. Forensic Sci Int 134:109-114
    • (2003) Forensic Sci Int , vol.134 , pp. 109-114
    • Thali, M.J.1    Yen, K.2    Schweitzer, W.3
  • 7
    • 0037346267 scopus 로고    scopus 로고
    • Virtopsy, a new imaging horizon in forensic pathology: Virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) - a feasibility study
    • Thali MJ, Yen K, Schweitzer W et al. (2003) Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) - a feasibility study. J Forensic Sci 48:386-403
    • (2003) J Forensic Sci , vol.48 , pp. 386-403
    • Thali, M.J.1    Yen, K.2    Schweitzer, W.3
  • 8
    • 33749496212 scopus 로고    scopus 로고
    • VIRTOPSY: Minimally invasive, imaging-guided virtual autopsy
    • Dirnhofer R, Jackowski C, Vock P et al. (2006) VIRTOPSY: minimally invasive, imaging-guided virtual autopsy. Radiographics 26:1305-1333
    • (2006) Radiographics , vol.26 , pp. 1305-1333
    • Dirnhofer, R.1    Jackowski, C.2    Vock, P.3
  • 9
    • 0028075730 scopus 로고
    • Utility of postmortem computed tomography in trauma victims
    • Donchin Y, Rivkind AI, Bar-Ziv J et al. (1994) Utility of postmortem computed tomography in trauma victims. J Trauma 37:552-556
    • (1994) J Trauma , vol.37 , pp. 552-556
    • Donchin, Y.1    Rivkind, A.I.2    Bar-Ziv, J.3
  • 10
    • 0025046948 scopus 로고
    • Preautopsy magnetic resonance imaging: Initial experience
    • Ros PR, Li KC, Vo P et al. (1990) Preautopsy magnetic resonance imaging: initial experience. Magn Reson Imaging 8:303-308
    • (1990) Magn Reson Imaging , vol.8 , pp. 303-308
    • Ros, P.R.1    Li, K.C.2    Vo, P.3
  • 11
    • 0242442634 scopus 로고    scopus 로고
    • Forensic microradiology: Micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone
    • Thali MJ, Taubenreuther U, Karolczak M et al. (2003) Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone. J Forensic Sci 48:1336-1342
    • (2003) J Forensic Sci , vol.48 , pp. 1336-1342
    • Thali, M.J.1    Taubenreuther, U.2    Karolczak, M.3
  • 12
    • 0035148654 scopus 로고    scopus 로고
    • Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: Preliminary clinical experience
    • Patriquin L, Kassarjian A, Barish M et al. (2001) Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience. J Magn Reson Imaging 13:277-287
    • (2001) J Magn Reson Imaging , vol.13 , pp. 277-287
    • Patriquin, L.1    Kassarjian, A.2    Barish, M.3
  • 13
    • 24644491195 scopus 로고    scopus 로고
    • Virtopsy: Postmortem minimally invasive angiography using cross section techniquesimplementation and preliminary results
    • Jackowski C, Sonnenschein M, Thali MJ et al. (2005) Virtopsy: postmortem minimally invasive angiography using cross section techniquesimplementation and preliminary results. J Forensic Sci 50:1175-1186
    • (2005) J Forensic Sci , vol.50 , pp. 1175-1186
    • Jackowski, C.1    Sonnenschein, M.2    Thali, M.J.3
  • 14
    • 43649097277 scopus 로고    scopus 로고
    • Postmortem whole-body CT angiography: Evaluation of two contrast media solutions
    • Ross S, Spendlove D, Bolliger S et al. (2008) Postmortem whole-body CT angiography: evaluation of two contrast media solutions. AJR Am J Roentgenol 190:1380-1389
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 1380-1389
    • Ross, S.1    Spendlove, D.2    Bolliger, S.3
  • 15
    • 0346037234 scopus 로고    scopus 로고
    • Analysis of patterned injuries and injury-causing instruments with forensic 3D/CAD supported photogrammetry (FPHG): An instruction manual for the documentation process
    • Brüschweiler W, Braun M, Dirnhofer R, Thali MJ (2003) Analysis of patterned injuries and injury-causing instruments with forensic 3D/CAD supported photogrammetry (FPHG): an instruction manual for the documentation process. Forensic Sci Int 132:130-138
    • (2003) Forensic Sci Int , vol.132 , pp. 130-138
    • Brüschweiler, W.1    Braun, M.2    Dirnhofer, R.3    Thali, M.J.4
  • 16
    • 0042665514 scopus 로고    scopus 로고
    • Bite mark documentation and analysis: The forensic 3D/CAD supported photogrammetry approach
    • Thali MJ, Braun M, Markwalder TH et al. (2003) Bite mark documentation and analysis: the forensic 3D/CAD supported photogrammetry approach. Forensic Sci Int 135:115-121
    • (2003) Forensic Sci Int , vol.135 , pp. 115-121
    • Thali, M.J.1    Braun, M.2    Markwalder, T.H.3
  • 17
    • 0242695004 scopus 로고    scopus 로고
    • 3D surface and body documentation in forensic medicine: 3- D/CAD Photogrammetry merged with 3D radiological scanning
    • Thali MJ, Braun M, Wirth J et al. (2003) 3D surface and body documentation in forensic medicine: 3- D/CAD Photogrammetry merged with 3D radiological scanning. J Forensic Sci 48:1356-1365
    • (2003) J Forensic Sci , vol.48 , pp. 1356-1365
    • Thali, M.J.1    Braun, M.2    Wirth, J.3
  • 18
    • 0036846702 scopus 로고    scopus 로고
    • Observation and identification of metabolites emerging during postmortem decomposition of brain tissue by means of in situ 1H-magnetic resonance spectroscopy
    • Ith M, Bigler P, Scheurer E et al. (2002) Observation and identification of metabolites emerging during postmortem decomposition of brain tissue by means of in situ 1H-magnetic resonance spectroscopy. Magn Reson Med 48:915-920
    • (2002) Magn Reson Med , vol.48 , pp. 915-920
    • Ith, M.1    Bigler, P.2    Scheurer, E.3
  • 19
    • 3142762397 scopus 로고    scopus 로고
    • Virtopsy: Forensic traumatology of the subcutaneous fatty tissue: Multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) as diagnostic tools
    • Yen K, Vock P, Tiefenthaler B et al. (2004) Virtopsy: forensic traumatology of the subcutaneous fatty tissue: multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) as diagnostic tools. J Forensic Sci 49:799-806
    • (2004) J Forensic Sci , vol.49 , pp. 799-806
    • Yen, K.1    Vock, P.2    Tiefenthaler, B.3
  • 21
    • 26244459836 scopus 로고    scopus 로고
    • Strangulation signs: Initial correlation of MRI, MSCT and forensic neck findings
    • Yen K, Thali M, Aghayev E et al. (2005) Strangulation signs: initial correlation of MRI, MSCT and forensic neck findings. J Magn Reson Imaging 22:501-510
    • (2005) J Magn Reson Imaging , vol.22 , pp. 501-510
    • Yen, K.1    Thali, M.2    Aghayev, E.3
  • 22
    • 33845666815 scopus 로고    scopus 로고
    • Full-body virtual autopsies using a state-of-the-art volume rendering pipeline
    • Ljung P, Winskog C, Persson A et al. (2006) Full-body virtual autopsies using a state-of-the-art volume rendering pipeline. IEEE Trans Vis Comput Graph 12:869-876
    • (2006) IEEE Trans Vis Comput Graph , vol.12 , pp. 869-876
    • Ljung, P.1    Winskog, C.2    Persson, A.3
  • 23
    • 33645801797 scopus 로고    scopus 로고
    • Maximum intensity projection of cranial computed tomography data for dental identification
    • Jackowski C, Aghayev E, Sonnenschein M et al. (2006) Maximum intensity projection of cranial computed tomography data for dental identification. Int J Legal Med 120:165-167
    • (2006) Int J Legal Med , vol.120 , pp. 165-167
    • Jackowski, C.1    Aghayev, E.2    Sonnenschein, M.3
  • 24
    • 33645220363 scopus 로고    scopus 로고
    • Dental CT imaging as a screening tool for dental profiling: Advantages and limitations
    • Thali MJ, Markwalder T, Jackowski C et al. (2006) Dental CT imaging as a screening tool for dental profiling: advantages and limitations. J Forensic Sci 51:113-119
    • (2006) J Forensic Sci , vol.51 , pp. 113-119
    • Thali, M.J.1    Markwalder, T.2    Jackowski, C.3
  • 25
    • 33745278859 scopus 로고    scopus 로고
    • Extended CT scale overcomes restoration caused streak artifacts-3D color encoded automatic discrimination of dental restorations for identification
    • Jackowski C, Lussi A, Classens M et al. (2006) Extended CT scale overcomes restoration caused streak artifacts-3D color encoded automatic discrimination of dental restorations for identification. J Comput Assist Tomogr 30:510-513
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 510-513
    • Jackowski, C.1    Lussi, A.2    Classens, M.3
  • 26
    • 34249663282 scopus 로고    scopus 로고
    • Use of multislice computed tomography in disaster victim identification: Advantages and limitations
    • Sidler M, Jackowski C, Dirnhofer R et al. (2007) Use of multislice computed tomography in disaster victim identification: advantages and limitations. Forensic Sci Int 169:118-128
    • (2007) Forensic Sci Int , vol.169 , pp. 118-128
    • Sidler, M.1    Jackowski, C.2    Dirnhofer, R.3
  • 27
    • 29244433744 scopus 로고    scopus 로고
    • Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination
    • Hayakawa M, Yamamoto S, Motani H et al. (2006) Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination. Int J Legal Med 120:24-26
    • (2006) Int J Legal Med , vol.120 , pp. 24-26
    • Hayakawa, M.1    Yamamoto, S.2    Motani, H.3
  • 28
    • 0024433595 scopus 로고
    • Three-dimensional imaging of an Egyptian mummy
    • Magid D, Bryan BM, Drebin RA et al. (1989) Three-dimensional imaging of an Egyptian mummy. Clin Imaging 13:239-240
    • (1989) Clin Imaging , vol.13 , pp. 239-240
    • Magid, D.1    Bryan, B.M.2    Drebin, R.A.3
  • 29
    • 0022643784 scopus 로고
    • Modern imaging and endoscopic biopsy techniques in Egyptian mummies
    • Notman DN, Tashjian J, Aufderheide AC et al. (1986) Modern imaging and endoscopic biopsy techniques in Egyptian mummies. AJR Am J Roentgenol 146:93-96
    • (1986) AJR Am J Roentgenol , vol.146 , pp. 93-96
    • Notman, D.N.1    Tashjian, J.2    Aufderheide, A.C.3
  • 30
    • 48349096039 scopus 로고    scopus 로고
    • Notes on the history of the radiological study of Egyptian mummies: From X-rays to new imaging techniques
    • Cosmacini P, Piacentini P (2008) Notes on the history of the radiological study of Egyptian mummies: from X-rays to new imaging techniques. Radiol Med 113:615-626
    • (2008) Radiol Med , vol.113 , pp. 615-626
    • Cosmacini, P.1    Piacentini, P.2
  • 31
    • 0003731907 scopus 로고    scopus 로고
    • Reducing risks, promoting health life
    • World Health Organisation, WHO, Geneva
    • World Health Organisation (2002) Reducing risks, promoting health life. The world health report. WHO, Geneva
    • (2002) The world health report
  • 32
    • 70350576114 scopus 로고    scopus 로고
    • National Center for Injury Prevention and Control, CDC, Atlanta
    • National Center for Injury Prevention and Control (2000) WISQARS - Leading causes of death reports. CDC, Atlanta
    • (2000) WISQARS - Leading Causes of Death Reports
  • 33
    • 0035003319 scopus 로고    scopus 로고
    • Characteristic features of suicidal drownings: A 20-year study
    • Byard RW, Houldsworth G, James RA et al. (2001) Characteristic features of suicidal drownings: a 20-year study. Am J Forensic Med Pathol 22:134-138
    • (2001) Am J Forensic Med Pathol , vol.22 , pp. 134-138
    • Byard, R.W.1    Houldsworth, G.2    James, R.A.3
  • 34
    • 0033530724 scopus 로고    scopus 로고
    • Patterns of drowning in Australia, 1992-1997
    • Mackie IJ (1999) Patterns of drowning in Australia, 1992-1997. Med J Aust 171:587-590
    • (1999) Med J Aust , vol.171 , pp. 587-590
    • Mackie, I.J.1
  • 35
    • 0033575110 scopus 로고    scopus 로고
    • Trends in unintentional drowning: The role of alcohol and medical care
    • Cummings P, Quan L (1999) Trends in unintentional drowning: the role of alcohol and medical care. JAMA 281:2198-2202
    • (1999) JAMA , vol.281 , pp. 2198-2202
    • Cummings, P.1    Quan, L.2
  • 36
    • 39049131582 scopus 로고    scopus 로고
    • Drowning-post-mortem imaging findings by computed tomography
    • Christe A, Aghayev E, Jackowski C et al. (2008) Drowning-post-mortem imaging findings by computed tomography. Eur Radiol 18:283-290
    • (2008) Eur Radiol , vol.18 , pp. 283-290
    • Christe, A.1    Aghayev, E.2    Jackowski, C.3
  • 37
    • 0029031598 scopus 로고
    • Three-dimensional reconstruction of a bullet path: Validation by computed radiography
    • Oliver WR, Chancellor AS, Soitys J et al. (1995) Three-dimensional reconstruction of a bullet path: validation by computed radiography. J Forensic Sci 40:321-324
    • (1995) J Forensic Sci , vol.40 , pp. 321-324
    • Oliver, W.R.1    Chancellor, A.S.2    Soitys, J.3
  • 38
    • 51049101236 scopus 로고    scopus 로고
    • Gunshot injuries detected by post-mortem multislice computed tomography (MSCT): A feasibility study
    • (Tokyo)
    • Andenmatten MA, Thali MJ, Kneubuehl BP et al. (2008) Gunshot injuries detected by post-mortem multislice computed tomography (MSCT): a feasibility study. Leg Med (Tokyo) 10:287-292
    • (2008) Leg Med , vol.10 , pp. 287-292
    • Andenmatten, M.A.1    Thali, M.J.2    Kneubuehl, B.P.3
  • 39
    • 0022907562 scopus 로고
    • Priority of multiple gunshot injuries of the skull
    • Madea B, Henssge C, Lockhoven HB (1986) Priority of multiple gunshot injuries of the skull. Z Rechtsmed 97:213-218
    • (1986) Z Rechtsmed , vol.97 , pp. 213-218
    • Madea, B.1    Henssge, C.2    Lockhoven, H.B.3
  • 40
    • 34548705951 scopus 로고    scopus 로고
    • Post-mortem forensic neuroimaging: Correlation of MSCT and MRI findings with autopsy results
    • Yen K, Lövblad KO, Scheurer E et al. (2007) Post-mortem forensic neuroimaging: correlation of MSCT and MRI findings with autopsy results. Forensic Sci Int 173:21-35
    • (2007) Forensic Sci Int , vol.173 , pp. 21-35
    • Yen, K.1    Lövblad, K.O.2    Scheurer, E.3
  • 41
    • 0036846443 scopus 로고    scopus 로고
    • Charred body: Virtual autopsy with multi-slice computed tomography and magnetic resonance imaging
    • Thali MJ, Yen K, Plattner T et al. (2002) Charred body: virtual autopsy with multi-slice computed tomography and magnetic resonance imaging. J Forensic Sci 47:1326-1331
    • (2002) J Forensic Sci , vol.47 , pp. 1326-1331
    • Thali, M.J.1    Yen, K.2    Plattner, T.3
  • 42
    • 0028087798 scopus 로고
    • Judicial hanging: Postmortem radiographic CT, and MR imaging features with autopsy confirmation
    • Wallace SK, Cohen WA, Stern EJ, Reay DT (1994) Judicial hanging: postmortem radiographic CT, and MR imaging features with autopsy confirmation. Radiology 193:263-267
    • (1994) Radiology , vol.193 , pp. 263-267
    • Wallace, S.K.1    Cohen, W.A.2    Stern, E.J.3    Reay, D.T.4
  • 43
    • 24044483852 scopus 로고    scopus 로고
    • Pneumomediastinum and soft tissue emphysema of the neck in postmortem CT and MRI: A new vital sign in hanging?
    • Aghayev E, Yen K, Sonnenschein M et al. (2005) Pneumomediastinum and soft tissue emphysema of the neck in postmortem CT and MRI: a new vital sign in hanging? Forensic Sci Int 153:181-188
    • (2005) Forensic Sci Int , vol.153 , pp. 181-188
    • Aghayev, E.1    Yen, K.2    Sonnenschein, M.3
  • 44
    • 0037373294 scopus 로고    scopus 로고
    • Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    • Alfakih K, Plein S, Thiele H et al. (2003) Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17:323-329
    • (2003) J Magn Reson Imaging , vol.17 , pp. 323-329
    • Alfakih, K.1    Plein, S.2    Thiele, H.3
  • 45
    • 0028273459 scopus 로고
    • Magnetic resonance imaging of chronic myocardial infarcts in formalin-fixed human autopsy hearts
    • Hsu JC, Johnson GA, Smith WM et al. (1994) Magnetic resonance imaging of chronic myocardial infarcts in formalin-fixed human autopsy hearts. Circulation 89:2133-2140
    • (1994) Circulation , vol.89 , pp. 2133-2140
    • Hsu, J.C.1    Johnson, G.A.2    Smith, W.M.3
  • 46
    • 14244255902 scopus 로고    scopus 로고
    • Virtopsy: Postmortem imaging of the human heart in situ using MSCT and MRI
    • Jackowski C, Schweitzer W, Thali M et al. (2005) Virtopsy: postmortem imaging of the human heart in situ using MSCT and MRI. Forensic Sci Int 149:11-23
    • (2005) Forensic Sci Int , vol.149 , pp. 11-23
    • Jackowski, C.1    Schweitzer, W.2    Thali, M.3
  • 47
    • 0036827099 scopus 로고    scopus 로고
    • Evaluation of methods for MR imaging of human right ventricular heart volumes and mass
    • Jauhiainen T, Jarvinen VM, Hekali PE (2002) Evaluation of methods for MR imaging of human right ventricular heart volumes and mass. Acta Radiol 43:587-592
    • (2002) Acta Radiol , vol.43 , pp. 587-592
    • Jauhiainen, T.1    Jarvinen, V.M.2    Hekali, P.E.3
  • 48
    • 0014735776 scopus 로고
    • The autopsy: Do we still need it?
    • Edwards JE (1970) The autopsy: do we still need it? Chest 57:113-114
    • (1970) Chest , vol.57 , pp. 113-114
    • Edwards, J.E.1
  • 49
    • 33846240922 scopus 로고    scopus 로고
    • Resident physician opinion on autopsy importance and procurement
    • Hull MJ, Nazarian RM, Wheeler AE et al. (2007) Resident physician opinion on autopsy importance and procurement. Hum Pathol 38:342-350
    • (2007) Hum Pathol , vol.38 , pp. 342-350
    • Hull, M.J.1    Nazarian, R.M.2    Wheeler, A.E.3
  • 50
    • 0035057418 scopus 로고    scopus 로고
    • Are coroners' necropsies necessary? A prospective study examining whether a "view and grant" system of death certification could be introduced into England and Wales
    • Rutty GN, Duerden RM, Carter N, Clark JC (2001) Are coroners' necropsies necessary? A prospective study examining whether a "view and grant" system of death certification could be introduced into England and Wales. J Clin Pathol 54:279-284
    • (2001) J Clin Pathol , vol.54 , pp. 279-284
    • Rutty, G.N.1    Duerden, R.M.2    Carter, N.3    Clark, J.C.4
  • 51
    • 75949118275 scopus 로고    scopus 로고
    • Do we still need autopsies
    • O'Mara MS, Battistella F (2004) Do we still need autopsies. Curr Surg 61:151-155
    • (2004) Curr Surg , vol.61 , pp. 151-155
    • O'Mara, M.S.1    Battistella, F.2
  • 53
    • 4143053654 scopus 로고    scopus 로고
    • The relation of autopsy rate to physicians' beliefs and recommendations regarding autopsy
    • Burton EC, Phillips RS, Covinsky KE et al. (2004) The relation of autopsy rate to physicians' beliefs and recommendations regarding autopsy. Am J Med 117:255-261
    • (2004) Am J Med , vol.117 , pp. 255-261
    • Burton, E.C.1    Phillips, R.S.2    Covinsky, K.E.3
  • 54
    • 75949107547 scopus 로고    scopus 로고
    • Association of directors of anatomic and surgical pathology
    • Recommendations for quality assurance and improvement in surgical and autopsy pathology
    • Nakhleh R, Coffin C, Cooper K (2006) Association of directors of anatomic and surgical pathology. Recommendations for quality assurance and improvement in surgical and autopsy pathology. Hum Pathol 37:985-988
    • (2006) Hum Pathol , vol.37 , pp. 985-988
    • Nakhleh, R.1    Coffin, C.2    Cooper, K.3
  • 55
    • 0345258500 scopus 로고    scopus 로고
    • Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) and subsequent correlation between radiology and autopsy findings
    • DOI 10.1016/S0379-0738(03)00225-1
    • Thali MJ, Yen K, Vock P et al. (2003) Image-guided virtual autopsy findings of gunshot victims performed with multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) and subsequent correlation between radiology and autopsy findings. Forensic Sci Int 138:8-16 (Pubitemid 37464726)
    • (2003) Forensic Science International , vol.138 , Issue.1-3 , pp. 8-16
    • Thali, M.J.1    Yen, K.2    Vock, P.3    Ozdoba, C.4    Kneubuehl, B.P.5    Sonnenschein, M.6    Dirnhofer, R.7
  • 56
    • 34147173764 scopus 로고    scopus 로고
    • Autopsy radiography: Digital radiographs (DR) vs multidetector computed tomography (MDCT) in high velocity gunshot wound victims
    • Harke HT, Levy AD, Abbott RM et al. (2007) Autopsy radiography: digital radiographs (DR) vs multidetector computed tomography (MDCT) in high velocity gunshot wound victims. Am J Forensic Med Pathol 28:13-19
    • (2007) Am J Forensic Med Pathol , vol.28 , pp. 13-19
    • Harke, H.T.1    Levy, A.D.2    Abbott, R.M.3
  • 57
    • 34249287406 scopus 로고    scopus 로고
    • Computed tomography as routine connection with medico-legal autopsies
    • Poulsen K, Simonsen J (2007) Computed tomography as routine connection with medico-legal autopsies. Forensic Sci Int 171:190-197
    • (2007) Forensic Sci Int , vol.171 , pp. 190-197
    • Poulsen, K.1    Simonsen, J.2
  • 58
    • 75949088651 scopus 로고    scopus 로고
    • L'autopsia nelle morti da arma da fuoco: Integrazione mediante TC spirale Utile contributo?
    • Pomara C, Marrone A, D'Errico S et al. (2005) L'autopsia nelle morti da arma da fuoco: integrazione mediante TC spirale. Utile contributo? Riv It Med Leg 6:1131-1140
    • (2005) Riv It Med Leg , vol.6 , pp. 1131-1140
    • Pomara, C.1    Marrone, A.2    D'Errico, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.