메뉴 건너뛰기




Volumn 37, Issue 2, 2010, Pages 934-946

Scatter correction method for x-ray CT using primary modulation: Phantom studies

Author keywords

Cone beam CT; Primary modulation; Scatter correction

Indexed keywords

EFFICIENCY; ELECTROMAGNETIC WAVE ATTENUATION; ERRORS; FREQUENCY MODULATION; MODULATORS; MONTE CARLO METHODS; PHANTOMS; X RAY DETECTORS;

EID: 75749149417     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3298014     Document Type: Article
Times cited : (73)

References (38)
  • 1
    • 0023792394 scopus 로고
    • An analytical model of the scattered radiation distribution in diagnostic radiology
    • DOI 10.1118/1.596186
    • J. Boone and J. Seibert, " An analytical model of the scattered radiation distribution in diagnostic radiology.," Med. Phys. MPHYA6 0094-2405 15 (5), 721-725 (1988). 10.1118/1.596186 (Pubitemid 18257584)
    • (1988) Medical Physics , vol.15 , Issue.5 , pp. 721-725
    • Boone, J.M.1    Seibert, J.A.2
  • 2
    • 0023752571 scopus 로고
    • X-ray scatter removal by deconvolution
    • DOI 10.1118/1.596208
    • J. Seibert and J. Boone, " X-ray scatter removal by deconvolution.," Med. Phys. MPHYA6 0094-2405 15 (4), 567-575 (1988). 10.1118/1.596208 (Pubitemid 18203900)
    • (1988) Medical Physics , vol.15 , Issue.4 , pp. 567-575
    • Seibert, J.A.1    Boone, J.M.2
  • 3
    • 0027893071 scopus 로고
    • Scatter compensation for digital chest radiography using maximum likelihood expectation maximization
    • INVRAV 0020-9996 (),. 10.1097/00004424-199305000-00009
    • C. E. Floyd, A. H. Baydush, J. Y. Lo, J. E. Bowsher, and C. E. Ravin, " Scatter compensation for digital chest radiography using maximum likelihood expectation maximization.," Invest. Radiol. INVRAV 0020-9996 28 (5), 427-433 (1993). 10.1097/00004424-199305000-00009
    • (1993) Invest. Radiol. , vol.28 , Issue.5 , pp. 427-433
    • Floyd, C.E.1    Baydush, A.H.2    Lo, J.Y.3    Bowsher, J.E.4    Ravin, C.E.5
  • 4
    • 0025890218 scopus 로고
    • Method for estimating the intensity of scattered radiation using a scatter generation model
    • MPHYA6 0094-2405 (),. 10.1118/1.596710
    • M. Honda, K. Kikuchi, and K. Komatsu, " Method for estimating the intensity of scattered radiation using a scatter generation model.," Med. Phys. MPHYA6 0094-2405 18 (2), 219-226 (1991). 10.1118/1.596710
    • (1991) Med. Phys. , vol.18 , Issue.2 , pp. 219-226
    • Honda, M.1    Kikuchi, K.2    Komatsu, K.3
  • 5
  • 6
    • 0028182136 scopus 로고
    • A regional convolution kernel algorithm for scatter correction in dual-energy images: Comparison to single-kernel algorithms
    • MPHYA6 0094-2405 (),. 10.1118/1.597297
    • D. G. Kruger, F. Zink, W. W. Peppler, D. L. Ergun, and C. A. Mistretta, " A regional convolution kernel algorithm for scatter correction in dual-energy images: Comparison to single-kernel algorithms.," Med. Phys. MPHYA6 0094-2405 21 (2), 175-184 (1994). 10.1118/1.597297
    • (1994) Med. Phys. , vol.21 , Issue.2 , pp. 175-184
    • Kruger, D.G.1    Zink, F.2    Peppler, W.W.3    Ergun, D.L.4    Mistretta, C.A.5
  • 7
    • 23844475227 scopus 로고    scopus 로고
    • Potential of software-based scatter corrections in cone-beam volume CT
    • DOI 10.1117/12.595032, 32, Medical Imaging 2005 - Physics of Medical Imaging
    • M. Bertram, J. Wiegert, and G. Rose, " Potential of software-based scatter corrections in cone-beam volume CT.," Proc. SPIE PSISDG 0277-786X 5745, 259-270 (2005). 10.1117/12.595032 (Pubitemid 41146374)
    • (2005) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5745 , Issue.1 , pp. 259-270
    • Bertram, M.1    Wiegert, J.2    Rose, G.3
  • 9
    • 0021868276 scopus 로고
    • Scatter rejection by air gaps: An empirical model
    • DOI 10.1118/1.595690
    • J. Sorenson and J. Floch, " Scatter rejection by air gap: An empirical model.," Med. Phys. MPHYA6 0094-2405 12 (3), 308-316 (1985). 10.1118/1.595690 (Pubitemid 15042816)
    • (1985) Medical Physics , vol.12 , Issue.3 , pp. 308-316
    • Sorenson, J.A.1    Floch, J.2
  • 10
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • MPHYA6 0094-2405 (),. 10.1118/1.596836
    • U. Neitzel, " Grids or air gaps for scatter reduction in digital radiography: A model calculation.," Med. Phys. MPHYA6 0094-2405 19 (2), 475-481 (1992). 10.1118/1.596836
    • (1992) Med. Phys. , vol.19 , Issue.2 , pp. 475-481
    • Neitzel, U.1
  • 11
    • 0028281468 scopus 로고
    • Scatter compensation in digital chest radiography using the posterior beam stop technique
    • DOI 10.1118/1.597388
    • J. Y. Lo, C. E. Floyd, J. A. Baker, and C. E. Ravin, " Scatter compensation in digital chest radiography using the posterior beam stop technique.," Med. Phys. MPHYA6 0094-2405 21 (3), 435-443 (1994). 10.1118/1.597388 (Pubitemid 24094959)
    • (1994) Medical Physics , vol.21 , Issue.3 , pp. 435-443
    • Lo, J.Y.1    Floyd Jr., C.E.2    Baker, J.A.3    Ravin, C.E.4
  • 12
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • DOI 10.1118/1.1711475
    • R. Ning, X. Tang, and D. Conover, " X-ray scatter correction algorithm for cone-beam CT imaging.," Med. Phys. MPHYA6 0094-2405 31 (5), 1195-1202 (2004). 10.1118/1.1711475 (Pubitemid 38656792)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1195-1202
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 14
    • 0032216602 scopus 로고    scopus 로고
    • Scatter-glare estimation for digital radiographic systems: Comparison of digital filtration and sampling techniques
    • ITMID4 0278-0062 (),. 10.1109/42.746621
    • S. Molloi, Y. Zhou, and G. Wamsely, " Scatter-glare estimation for digital radiographic systems: Comparison of digital filtration and sampling techniques.," IEEE Trans. Med. Imaging ITMID4 0278-0062 17 (6), 881-888 (1998). 10.1109/42.746621
    • (1998) IEEE Trans. Med. Imaging , vol.17 , Issue.6 , pp. 881-888
    • Molloi, S.1    Zhou, Y.2    Wamsely, G.3
  • 15
    • 23844519433 scopus 로고    scopus 로고
    • X-ray scatter correction for cone-beam CT using moving blocker array
    • DOI 10.1117/12.594699, 31, Medical Imaging 2005 - Physics of Medical Imaging
    • L. Zhu, N. Strobel, and R. Fahrig, " X-ray scatter correction for cone-beam CT using moving blocker array.," Proc. SPIE PSISDG 0277-786X 5745, 251-258 (2005). 10.1117/12.594699 (Pubitemid 41146373)
    • (2005) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5745 , Issue.1 , pp. 251-258
    • Zhu, L.1    Strobel, N.2    Fahrig, R.3
  • 16
    • 0036151527 scopus 로고    scopus 로고
    • Grid and slot scan scatter reduction in mammography: Comparison by using Monte Carlo techniques
    • RADLAX 0033-8419 (),. 10.1148/radiol.2222010491
    • J. Boone, J. Seibert, C. Tang, and S. Lane, " Grid and slot scan scatter reduction in mammography: Comparison by using Monte Carlo techniques.," Radiology RADLAX 0033-8419 222 (2), 519-527 (2002). 10.1148/radiol.2222010491
    • (2002) Radiology , vol.222 , Issue.2 , pp. 519-527
    • Boone, J.1    Seibert, J.2    Tang, C.3    Lane, S.4
  • 17
    • 18844451277 scopus 로고    scopus 로고
    • Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems
    • DOI 10.1148/radiol.2353040516
    • E. Samei, J. Y. Lo, T. T. Yoshizumi, J. L. Jesneck, J. T. Dobbins III, C. E. Floyd, Jr., H. P. McAdams, and C. E. Ravin, " Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems.," Radiology RADLAX 0033-8419 235 (3), 940-949 (2005). 10.1148/radiol.2353040516 (Pubitemid 40695893)
    • (2005) Radiology , vol.235 , Issue.3 , pp. 940-949
    • Samel, E.1    Lo, J.Y.2    Yoshizumi, T.T.3    Jesneck, J.L.4    Dobbins III, J.T.5    Floyd Jr., C.E.6    McAdams, H.P.7    Ravin, C.E.8
  • 18
    • 0022455545 scopus 로고
    • Scatter correction algorithm for digitally acquired radiographics: Theory and results
    • DOI 10.1118/1.595920
    • J. Boone, " Scatter correction algorithm for digitally acquired radiographs: Theory and results.," Med. Phys. MPHYA6 0094-2405 13 (3), 319-328 (1986). 10.1118/1.595920 (Pubitemid 16062263)
    • (1986) Medical Physics , vol.13 , Issue.3 , pp. 319-328
    • Boone, J.M.1
  • 19
    • 84907631001 scopus 로고    scopus 로고
    • Cone beam x-ray scatter removal via image frequency modulation and filtering
    • MPHYA6 0094-2405 (),. 10.1118/1.1998387
    • A. Bani-Hashemi, E. Blanz, J. Maltz, D. Hristov, and M. Svatos, " Cone beam x-ray scatter removal via image frequency modulation and filtering.," Med. Phys. MPHYA6 0094-2405 32 (6), 2093 (2005). 10.1118/1.1998387
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 2093
    • Bani-Hashemi, A.1    Blanz, E.2    Maltz, J.3    Hristov, D.4    Svatos, M.5
  • 20
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
    • DOI 10.1118/1.2148916
    • J. H. Siewerdsen, M. J. Daly, B. Bakhtiar, D. J. Moseley, S. Richard, H. Keller, and D. A. Jaffray, " A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT.," Med. Phys. MPHYA6 0094-2405 33 (1), 187-197 (2006). 10.1118/1.2148916 (Pubitemid 43121048)
    • (2006) Medical Physics , vol.33 , Issue.1 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6    Jaffray, D.A.7
  • 21
    • 66449132276 scopus 로고    scopus 로고
    • Scatter correction for cone-beam CT in radiation therapy
    • MPHYA6 0094-2405 (),. 10.1118/1.3130047
    • L. Zhu, Y. Xie, J. Wang, and L. Xing, " Scatter correction for cone-beam CT in radiation therapy.," Med. Phys. MPHYA6 0094-2405 36 (6), 2258-2268 (2009). 10.1118/1.3130047
    • (2009) Med. Phys. , vol.36 , Issue.6 , pp. 2258-2268
    • Zhu, L.1    Xie, Y.2    Wang, J.3    Xing, L.4
  • 22
    • 0023212881 scopus 로고
    • Scatter estimation for a digital radiographic system using convolution filtering
    • DOI 10.1118/1.596126
    • L. A. Love and R. A. Kruger, " Scatter estimation for a digital radiographic system using convolution filtering.," Med. Phys. MPHYA6 0094-2405 14 (2), 178-185 (1987). 10.1118/1.596126 (Pubitemid 17063679)
    • (1987) Medical Physics , vol.14 , Issue.2 , pp. 178-185
    • Love, L.A.1    Kruger, R.A.2
  • 23
    • 33845567776 scopus 로고    scopus 로고
    • Combining deterministic and Monte-Carlo methods in the simulation of x-ray attenuation and scatter
    • ZZZZZZ 0938-7994 (Su1).
    • Y. Kyriakou, P. Deak, T. Riedel, L. V. Smekal, and W. A. Kalender, " Combining deterministic and Monte-Carlo methods in the simulation of x-ray attenuation and scatter.," Eur. Radiol. ZZZZZZ 0938-7994 15 (Supp. 1), 306 (2005).
    • (2005) Eur. Radiol. , vol.15 , pp. 306
    • Kyriakou, Y.1    Deak, P.2    Riedel, T.3    Smekal, L.V.4    Kalender, W.A.5
  • 24
    • 33748518881 scopus 로고    scopus 로고
    • Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT
    • DOI 10.1088/0031-9155/51/18/008, PII S0031915506243999, 008
    • Y. Kyriakou, T. Riedel, and W. A. Kalender, " Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT.," Phys. Med. Biol. PHMBA7 0031-9155 51, 4567-4586 (2006). 10.1088/0031-9155/51/18/008 (Pubitemid 44362515)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.18 , pp. 4567-4586
    • Kyriakou, Y.1    Riedel, T.2    Kalender, W.A.3
  • 25
    • 0032825050 scopus 로고    scopus 로고
    • Regularization method for scatter-glare correction in fluoroscopic images
    • DOI 10.1118/1.598683
    • R. A. Close, K. C. Shah, and J. S. Whiting, " Regularization method for scatter-glare correction in fluoroscopic images.," Med. Phys. MPHYA6 0094-2405 26 (9), 1794-1801 (1999). 10.1118/1.598683 (Pubitemid 29442260)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1794-1801
    • Close, R.A.1    Shah, K.C.2    Whiting, J.S.3
  • 26
    • 33845562622 scopus 로고    scopus 로고
    • Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results
    • DOI 10.1109/TMI.2006.884636
    • L. Zhu, N. R. Bennett, and R. Fahrig, " Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25 (12), 1573-1587 (2006). 10.1109/TMI.2006.884636 (Pubitemid 44936707)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.12 , pp. 1573-1587
    • Zhu, L.1    Bennett, N.R.2    Fahrig, R.3
  • 27
  • 28
    • 0021248140 scopus 로고
    • Characterization of the veiling glare PSF in x-ray image intensified fluoroscopy
    • DOI 10.1118/1.595494
    • J. A. Seibert, O. Nalcioglu, and W. W. Roeck, " Characterization of the veiling glare PSF in x-ray image intensified fluoroscopy.," Med. Phys. MPHYA6 0094-2405 11 (2), 172-179 (1984). 10.1118/1.595494 (Pubitemid 14107163)
    • (1984) Medical Physics , vol.11 , Issue.2 , pp. 172-179
    • Seibert, J.A.1    Nalcioglu, O.2    Roeck, W.W.3
  • 29
    • 75749098740 scopus 로고    scopus 로고
    • Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging
    • OPEGAR 0091-3286 (),. 10.1117/1.2977527
    • W. Cai, R. Ning, and D. Conover, " Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging.," Opt. Eng. OPEGAR 0091-3286 47 (9), 097003 (2008). 10.1117/1.2977527
    • (2008) Opt. Eng. , vol.47 , Issue.9 , pp. 097003
    • Cai, W.1    Ning, R.2    Conover, D.3
  • 30
    • 61549101239 scopus 로고    scopus 로고
    • The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector
    • MPHYA6 0094-2405 (),. 10.1118/1.3077922
    • A. K. Carton, R. Acciavatti, J. Kuo, and A. D. A. Maidment, " The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector.," Med. Phys. MPHYA6 0094-2405 36 (3), 920-928 (2009). 10.1118/1.3077922
    • (2009) Med. Phys. , vol.36 , Issue.3 , pp. 920-928
    • Carton, A.K.1    Acciavatti, R.2    Kuo, J.3    Maidment, A.D.A.4
  • 31
    • 85024787557 scopus 로고    scopus 로고
    • Scatter characterization in cone-beam CT systems with offset flat panel imagers
    • MPHYA6 0094-2405 (),. 10.1118/1.2241938
    • G. Virshup, R. Suri, and J. Star-Lack, " Scatter characterization in cone-beam CT systems with offset flat panel imagers.," Med. Phys. MPHYA6 0094-2405 33 (6), 2288-2288 (2006). 10.1118/1.2241938
    • (2006) Med. Phys. , vol.33 , Issue.6 , pp. 2288-2288
    • Virshup, G.1    Suri, R.2    Star-Lack, J.3
  • 32
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • JOAOD6 0740-3232,. 10.1364/JOSAA.1.000612
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. A JOAOD6 0740-3232 1, 612-619 (1984). 10.1364/JOSAA.1.000612
    • (1984) J. Opt. Soc. Am. A , vol.1 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 33
    • 35148860193 scopus 로고    scopus 로고
    • A fast variable-intensity ring suppression algorithm
    • MPHYA6 0094-2405 (),. 10.1118/1.2240242
    • J. Star-Lack, J. Starman, P. Munro, A. Jeung, J. Richters, H. Mostafavi, and J. Pavkovich, " A fast variable-intensity ring suppression algorithm.," Med. Phys. MPHYA6 0094-2405 33 (6), 1997-1997 (2006). 10.1118/1.2240242
    • (2006) Med. Phys. , vol.33 , Issue.6 , pp. 1997-1997
    • Star-Lack, J.1    Starman, J.2    Munro, P.3    Jeung, A.4    Richters, J.5    Mostafavi, H.6    Pavkovich, J.7
  • 34
    • 61349173033 scopus 로고    scopus 로고
    • Noise suppression in scatter correction for cone-beam CT
    • MPHYA6 0094-2405 (),. 10.1118/1.3063001
    • L. Zhu, J. Wang, and L. Xing, " Noise suppression in scatter correction for cone-beam CT.," Med. Phys. MPHYA6 0094-2405 36 (3), 741-752 (2009). 10.1118/1.3063001
    • (2009) Med. Phys. , vol.36 , Issue.3 , pp. 741-752
    • Zhu, L.1    Wang, J.2    Xing, L.3
  • 35
    • 58149115069 scopus 로고    scopus 로고
    • The influence of bowtie filtration on cone-beam CT image quality
    • MPHYA6 0094-2405 (),. 10.1118/1.3017470
    • N. Mail, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray, " The influence of bowtie filtration on cone-beam CT image quality.," Med. Phys. MPHYA6 0094-2405 36 (1), 22-32 (2009). 10.1118/1.3017470
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 22-32
    • Mail, N.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 36
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • JCATD5 0363-8715 ().
    • K. Lange and R. Carson, " EM reconstruction algorithms for emission and transmission tomography.," J. Comput. Assist. Tomogr. JCATD5 0363-8715 8 (2), 306-316 (1984).
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 37
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • DOI 10.1118/1.1915015
    • P. J. La Rivìre, " Penalized-likelihood sinogram smoothing for low-dose CT.," Med. Phys. MPHYA6 0094-2405 32 (6), 1676-1683 (2005). 10.1118/1.1915015 (Pubitemid 40880561)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1676-1683
    • La Riviere, P.J.1
  • 38
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • DOI 10.1109/TMI.2006.882141
    • J. Wang, T. Li, H. Lu, and Z. Liang, " Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray computed tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25 (10), 1272-1283 (2006). 10.1109/TMI.2006.882141 (Pubitemid 46417077)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.