-
2
-
-
0022260368
-
Respiratory ordered phase encoding (ROPE): A method for reducing respiratory motion artifacts in MR imaging
-
Bailes DR, Gilderdale DJ, Bydder GM, Collins AG, Firmin DN. Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artifacts in MR imaging. J Comput Assist Tomogr 1985; 9:835-838.
-
(1985)
J Comput Assist Tomogr
, vol.9
, pp. 835-838
-
-
Bailes, D.R.1
Gilderdale, D.J.2
Bydder, G.M.3
Collins, A.G.4
Firmin, D.N.5
-
3
-
-
0029123801
-
The diminishing variance algorithm for real-time reduction of motion artifacts in MRI
-
Sachs TS, Meyer CH, Irarrazabal P, Hu BS, Nishimura DG, Macovski A. The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med 1995;34:412-422.
-
(1995)
Magn Reson Med
, vol.34
, pp. 412-422
-
-
Sachs, T.S.1
Meyer, C.H.2
Irarrazabal, P.3
Hu, B.S.4
Nishimura, D.G.5
Macovski, A.6
-
4
-
-
0346373771
-
Self-gated cardiac cine MRI
-
Larson AC, White RD, Laub G, McVeigh ER, Li D, Simonetti OP. Self-gated cardiac cine MRI. Magn Reson Med 2004;51:93-102.
-
(2004)
Magn Reson Med
, vol.51
, pp. 93-102
-
-
Larson, A.C.1
White, R.D.2
Laub, G.3
McVeigh, E.R.4
Li, D.5
Simonetti, O.P.6
-
5
-
-
10044240735
-
Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
-
Liu C, Bammer R, Kim D, Mosley ME. Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging. Magn Reson Med 2004;52:1388-1396.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1388-1396
-
-
Liu, C.1
Bammer, R.2
Kim, D.3
Mosley, M.E.4
-
6
-
-
0032754594
-
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
-
Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
-
(1999)
Magn Reson Med
, vol.42
, pp. 963-969
-
-
Pipe, J.G.1
-
7
-
-
0024453449
-
Adaptive technique for high-definition MR imaging of moving structures
-
Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989;173:255-263.
-
(1989)
Radiology
, vol.173
, pp. 255-263
-
-
Ehman, R.L.1
Felmlee, J.P.2
-
8
-
-
0028886141
-
Orbital navigator echoes for motion measurements in magnetic resonance imaging
-
Fu ZW, Wang Y, Grimm RC, Rossman PJ, Felmlee JP, Riederer SJ, Ehman RL. Orbital navigator echoes for motion measurements in magnetic resonance imaging. Magn Reson Med 1995;34:746-753.
-
(1995)
Magn Reson Med
, vol.34
, pp. 746-753
-
-
Fu, Z.W.1
Wang, Y.2
Grimm, R.C.3
Rossman, P.J.4
Felmlee, J.P.5
Riederer, S.J.6
Ehman, R.L.7
-
9
-
-
0036136070
-
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
-
Welch EB, Manduca A, Grimm RC, Ward HA, Jack CR Jr. Spherical navigator echoes for full 3D rigid body motion measurement in MRI. Magn Reson Med 2002;47:32-41.
-
(2002)
Magn Reson Med
, vol.47
, pp. 32-41
-
-
Welch, E.B.1
Manduca, A.2
Grimm, R.C.3
Ward, H.A.4
Jack Jr., C.R.5
-
10
-
-
0842307385
-
Floating navigator echo (FNAV) for in-plane 2D translational motion estimation
-
Kadah YM, Abaza AA, Fahmy AS, Youssef AM, Heberlein K, Hu XP. Floating navigator echo (FNAV) for in-plane 2D translational motion estimation. Magn Reson Med 2004;51:403-407.
-
(2004)
Magn Reson Med
, vol.51
, pp. 403-407
-
-
Kadah, Y.M.1
Abaza, A.A.2
Fahmy, A.S.3
Youssef, A.M.4
Heberlein, K.5
Hu, X.P.6
-
11
-
-
0037228266
-
Reconstruction after rotational motion
-
Atkinson D, Hill DLG. Reconstruction after rotational motion. Magn Reson Med.2003;49:183-187.
-
(2003)
Magn Reson Med
, vol.49
, pp. 183-187
-
-
Atkinson, D.1
Hill, D.L.G.2
-
13
-
-
26844551530
-
Ghost artifact removal using a parallel imaging approach
-
Winkelmann R, Börnert P, Dössel O. Ghost artifact removal using a parallel imaging approach. Magn Reson Med 2005;54:1002-1009.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1002-1009
-
-
Winkelmann, R.1
Börnert, P.2
Dössel, O.3
-
14
-
-
4744369964
-
Coil-Based Artifact Reduction
-
Atkinson D, Larkman DJ, Batchelor PG, Hill DLG, Hajnal JV. Coil-Based Artifact Reduction. Magn Reson Med 2004;52:825-830.
-
(2004)
Magn Reson Med
, vol.52
, pp. 825-830
-
-
Atkinson, D.1
Larkman, D.J.2
Batchelor, P.G.3
Hill, D.L.G.4
Hajnal, J.V.5
-
15
-
-
0036206253
-
Detection and elimination of motion artifacts by regeneration of k-space
-
Bydder M, Larkman DJ, Hajnal. Detection and elimination of motion artifacts by regeneration of k-space. Magn Reson Med 2002;47: 677-686.
-
(2002)
Magn Reson Med
, vol.47
, pp. 677-686
-
-
Bydder, M.1
Larkman, D.J.2
Hajnal3
-
16
-
-
12244268672
-
SMASH navigators
-
Bydder M, Atkinson D, Larkman DJ, Hill DLG, Hajnal JV. SMASH navigators. Magn Reson Med 2003;49:493-500.
-
(2003)
Magn Reson Med
, vol.49
, pp. 493-500
-
-
Bydder, M.1
Atkinson, D.2
Larkman, D.J.3
Hill, D.L.G.4
Hajnal, J.V.5
-
17
-
-
33846118318
-
Artifact reduction in moving-table acquisitions using parallel imaging and multiple averages
-
Fautz HP, Honal M, Saueressig U, Schafer O, Kannengiesser SAR. Artifact reduction in moving-table acquisitions using parallel imaging and multiple averages. Magn Reson Med 2007;57:226-232.
-
(2007)
Magn Reson Med
, vol.57
, pp. 226-232
-
-
Fautz, H.P.1
Honal, M.2
Saueressig, U.3
Schafer, O.4
Kannengiesser, S.A.R.5
-
18
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haasse A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47: 1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haasse, A.8
-
19
-
-
28444471600
-
Parallel magnetic resonance imaging using the GRAPPA operator formalism
-
Griswold MA, Blaimer M, Breuer F, Heidemann RM, Mueller M, Jakob PM. Parallel magnetic resonance imaging using the GRAPPA operator formalism. Magn Reson Med 2005;54:1553-1556.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1553-1556
-
-
Griswold, M.A.1
Blaimer, M.2
Breuer, F.3
Heidemann, R.M.4
Mueller, M.5
Jakob, P.M.6
-
20
-
-
37349080140
-
A software channel compression technique for faster reconstruction with many channels
-
Huang F, Vijayakumar S, Li Y, Hertel S, Duensing G. A software channel compression technique for faster reconstruction with many channels. Magn Reson Imag 2007;26:133-141.
-
(2007)
Magn Reson Imag
, vol.26
, pp. 133-141
-
-
Huang, F.1
Vijayakumar, S.2
Li, Y.3
Hertel, S.4
Duensing, G.5
-
22
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
24
-
-
0029969802
-
Improved image registration by using Fourier interpolation
-
Eddy WF, Fitzgerald M, Noll DC. Improved image registration by using Fourier interpolation. Magn Reson Med 1996;36:923-931.
-
(1996)
Magn Reson Med
, vol.36
, pp. 923-931
-
-
Eddy, W.F.1
Fitzgerald, M.2
Noll, D.C.3
-
25
-
-
27644511256
-
Matrix description of general motion correction applied to multishot images
-
Batchelor PG, Atkinson D, Irarrazavel P, Hill DLG, Hajnal JV, Larkman DJ. Matrix description of general motion correction applied to multishot images. Magn Reson Med 2005;54:1273-1280.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1273-1280
-
-
Batchelor, P.G.1
Atkinson, D.2
Irarrazavel, P.3
Hill, D.L.G.4
Hajnal, J.V.5
Larkman, D.J.6
-
26
-
-
36849019962
-
Non-cartesian data reconstruction using GRAPPA operator gridding (GROG)
-
Seiberlich N, Breuer FA, Blaimer M, Barkauskas K, Jakob PM, Griswold MA. Non-cartesian data reconstruction using GRAPPA operator gridding (GROG). Magn Reson Med 2007;58:1257-1265.
-
(2007)
Magn Reson Med
, vol.58
, pp. 1257-1265
-
-
Seiberlich, N.1
Breuer, F.A.2
Blaimer, M.3
Barkauskas, K.4
Jakob, P.M.5
Griswold, M.A.6
|