메뉴 건너뛰기




Volumn 23, Issue 2, 2010, Pages 134-140

Clinical Value of Real-Time Three-Dimensional Echocardiography for Right Ventricular Quantification in Congenital Heart Disease: Validation With Cardiac Magnetic Resonance Imaging

Author keywords

Congenital heart disease; Real time three dimensional echocardiography; Right ventricular function

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CONGENITAL HEART DISEASE; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; FEMALE; HEART RIGHT VENTRICLE EJECTION FRACTION; HEART RIGHT VENTRICLE VOLUME; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OBSERVER VARIATION; QUANTITATIVE DIAGNOSIS; REPRODUCIBILITY; THREE DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 75749104668     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.echo.2009.12.001     Document Type: Article
Times cited : (132)

References (31)
  • 2
    • 0027162172 scopus 로고
    • Long-term outcome in patients undergoing surgical repair of tetralogy of Fallot
    • Murphy J.G., Gersh B.J., Mair D.D., Fuster V., McGoon M.D., Ilstrup D.M., et al. Long-term outcome in patients undergoing surgical repair of tetralogy of Fallot. N Engl J Med 329 (1993) 593-599
    • (1993) N Engl J Med , vol.329 , pp. 593-599
    • Murphy, J.G.1    Gersh, B.J.2    Mair, D.D.3    Fuster, V.4    McGoon, M.D.5    Ilstrup, D.M.6
  • 3
    • 33645215083 scopus 로고    scopus 로고
    • The right ventricle in congenital heart disease
    • Davlouros P.A., Niwa K., Webb G., and Gatzoulis M.A. The right ventricle in congenital heart disease. Heart 92 Suppl (2006) i27-i38
    • (2006) Heart , vol.92 , Issue.SUPPL
    • Davlouros, P.A.1    Niwa, K.2    Webb, G.3    Gatzoulis, M.A.4
  • 4
    • 0037066051 scopus 로고    scopus 로고
    • Heart failure and ventricular dysfunction in patients with single or systemic right ventricles
    • Piran S., Veldtman G., Siu S., Webb G.D., and Liu P.P. Heart failure and ventricular dysfunction in patients with single or systemic right ventricles. Circulation 105 (2002) 1189-1194
    • (2002) Circulation , vol.105 , pp. 1189-1194
    • Piran, S.1    Veldtman, G.2    Siu, S.3    Webb, G.D.4    Liu, P.P.5
  • 5
    • 33645225636 scopus 로고    scopus 로고
    • Assessing right ventricular function: the role of echocardiography and complementary technologies
    • Bleeker G.B., Steendijk P., Holman E.R., Yu C.M., Breithardt O.A., Kaandorp T.A., et al. Assessing right ventricular function: the role of echocardiography and complementary technologies. Heart 92 Suppl (2006) i19-i26
    • (2006) Heart , vol.92 , Issue.SUPPL
    • Bleeker, G.B.1    Steendijk, P.2    Holman, E.R.3    Yu, C.M.4    Breithardt, O.A.5    Kaandorp, T.A.6
  • 6
    • 33846590995 scopus 로고    scopus 로고
    • Non-invasive imaging in adult congenital heart disease using cardiovascular magnetic resonance
    • Babu-Narayan S.V., Gatzoulis M.A., and Kilner P.J. Non-invasive imaging in adult congenital heart disease using cardiovascular magnetic resonance. J Cardiovasc Med (Hagerstown) 8 (2007) 23-29
    • (2007) J Cardiovasc Med (Hagerstown) , vol.8 , pp. 23-29
    • Babu-Narayan, S.V.1    Gatzoulis, M.A.2    Kilner, P.J.3
  • 7
    • 63049113820 scopus 로고    scopus 로고
    • Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers
    • Pulver A.F., Puchalski M.D., Bradley D.J., Minich L.L., Su J.T., Saarel E.V., et al. Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers. Pacing Clin Electrophysiol 32 (2009) 450-456
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 450-456
    • Pulver, A.F.1    Puchalski, M.D.2    Bradley, D.J.3    Minich, L.L.4    Su, J.T.5    Saarel, E.V.6
  • 8
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • Sugeng L., Mor-Avi V., Weinert L., Niel J., Ebner C., Steringer-Mascherbauer R., et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 114 (2006) 654-661
    • (2006) Circulation , vol.114 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3    Niel, J.4    Ebner, C.5    Steringer-Mascherbauer, R.6
  • 9
    • 50949129275 scopus 로고    scopus 로고
    • Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance
    • Soliman O.I., Kirschbaum S.W., van Dalen B.M., van der Zwaan H.B., Delavary B.M., Vletter W.B., et al. Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance. Am J Cardiol 102 (2008) 778-783
    • (2008) Am J Cardiol , vol.102 , pp. 778-783
    • Soliman, O.I.1    Kirschbaum, S.W.2    van Dalen, B.M.3    van der Zwaan, H.B.4    Delavary, B.M.5    Vletter, W.B.6
  • 10
    • 30844431512 scopus 로고    scopus 로고
    • Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease
    • van den Bosch A.E., Robbers-Visser D., Krenning B.J., Voormolen M.M., McGhie J.S., Helbing W.A., et al. Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease. J Am Soc Echocardiogr 19 (2006) 1-6
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1-6
    • van den Bosch, A.E.1    Robbers-Visser, D.2    Krenning, B.J.3    Voormolen, M.M.4    McGhie, J.S.5    Helbing, W.A.6
  • 11
    • 0029128023 scopus 로고
    • Comparison of echocardiographic methods with magnetic resonance imaging for assessment of right ventricular function in children
    • Helbing W.A., Bosch H.G., Maliepaard C., Rebergen S.A., van der Geest R.J., Hansen B., et al. Comparison of echocardiographic methods with magnetic resonance imaging for assessment of right ventricular function in children. Am J Cardiol 76 (1995) 589-594
    • (1995) Am J Cardiol , vol.76 , pp. 589-594
    • Helbing, W.A.1    Bosch, H.G.2    Maliepaard, C.3    Rebergen, S.A.4    van der Geest, R.J.5    Hansen, B.6
  • 12
    • 34247629514 scopus 로고    scopus 로고
    • Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
    • Gopal A.S., Chukwu E.O., Iwuchukwu C.J., Katz A.S., Toole R.S., Schapiro W., et al. Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: comparison with cardiac magnetic resonance imaging. J Am Soc Echocardiogr 20 (2007) 445-455
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 445-455
    • Gopal, A.S.1    Chukwu, E.O.2    Iwuchukwu, C.J.3    Katz, A.S.4    Toole, R.S.5    Schapiro, W.6
  • 13
    • 33846025104 scopus 로고    scopus 로고
    • Quantitative echocardiographic analysis of the right ventricle in healthy individuals
    • Kjaergaard J., Sogaard P., and Hassager C. Quantitative echocardiographic analysis of the right ventricle in healthy individuals. J Am Soc Echocardiogr 19 (2006) 1365-1372
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1365-1372
    • Kjaergaard, J.1    Sogaard, P.2    Hassager, C.3
  • 14
    • 35248879820 scopus 로고    scopus 로고
    • Anatomically oriented right ventricular volume measurements with dynamic three-dimensional echocardiography validated by 3-Tesla magnetic resonance imaging
    • Niemann P.S., Pinho L., Balbach T., Galuschky C., Blankenhagen M., Silberbach M., et al. Anatomically oriented right ventricular volume measurements with dynamic three-dimensional echocardiography validated by 3-Tesla magnetic resonance imaging. J Am Coll Cardiol 50 (2007) 1668-1676
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1668-1676
    • Niemann, P.S.1    Pinho, L.2    Balbach, T.3    Galuschky, C.4    Blankenhagen, M.5    Silberbach, M.6
  • 15
    • 37349089012 scopus 로고    scopus 로고
    • Accuracy and reproducibility of real-time three-dimensional echocardiography for assessment of right ventricular volumes and ejection fraction in children
    • Lu X., Nadvoretskiy V., Bu L., Stolpen A., Ayres N., Pignatelli R.H., et al. Accuracy and reproducibility of real-time three-dimensional echocardiography for assessment of right ventricular volumes and ejection fraction in children. J Am Soc Echocardiogr 21 (2008) 84-89
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 84-89
    • Lu, X.1    Nadvoretskiy, V.2    Bu, L.3    Stolpen, A.4    Ayres, N.5    Pignatelli, R.H.6
  • 16
    • 34247624529 scopus 로고    scopus 로고
    • Variables influencing the accuracy of right ventricular volume assessment by real-time 3-dimensional echocardiography: an in vitro validation study
    • Hoch M., Vasilyev N.V., Soriano B., Gauvreau K., and Marx G.R. Variables influencing the accuracy of right ventricular volume assessment by real-time 3-dimensional echocardiography: an in vitro validation study. J Am Soc Echocardiogr 20 (2007) 456-461
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 456-461
    • Hoch, M.1    Vasilyev, N.V.2    Soriano, B.3    Gauvreau, K.4    Marx, G.R.5
  • 17
    • 69049102105 scopus 로고    scopus 로고
    • Right ventricle three-dimensional echography in corrected tetralogy of Fallot: accuracy and variability
    • Iriart X., Montaudon M., Lafitte S., Chabaneix J., Reant P., Balbach T., et al. Right ventricle three-dimensional echography in corrected tetralogy of Fallot: accuracy and variability. Eur J Echocardiogr 10 (2009) 784-792
    • (2009) Eur J Echocardiogr , vol.10 , pp. 784-792
    • Iriart, X.1    Montaudon, M.2    Lafitte, S.3    Chabaneix, J.4    Reant, P.5    Balbach, T.6
  • 18
    • 0037373294 scopus 로고    scopus 로고
    • Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    • Alfakih K., Plein S., Thiele H., Jones T., Ridgway J.P., and Sivananthan M.U. Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17 (2003) 323-329
    • (2003) J Magn Reson Imaging , vol.17 , pp. 323-329
    • Alfakih, K.1    Plein, S.2    Thiele, H.3    Jones, T.4    Ridgway, J.P.5    Sivananthan, M.U.6
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0842304408 scopus 로고    scopus 로고
    • Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance
    • Grothues F., Moon J.C., Bellenger N.G., Smith G.S., Klein H.U., and Pennell D.J. Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J 147 (2004) 218-223
    • (2004) Am Heart J , vol.147 , pp. 218-223
    • Grothues, F.1    Moon, J.C.2    Bellenger, N.G.3    Smith, G.S.4    Klein, H.U.5    Pennell, D.J.6
  • 21
  • 22
    • 43449098147 scopus 로고    scopus 로고
    • Cardiac magnetic resonance imaging for the evaluation of ventricular function
    • Sarwar A., Shapiro M.D., Abbara S., and Cury R.C. Cardiac magnetic resonance imaging for the evaluation of ventricular function. Semin Roentgenol 43 (2008) 183-192
    • (2008) Semin Roentgenol , vol.43 , pp. 183-192
    • Sarwar, A.1    Shapiro, M.D.2    Abbara, S.3    Cury, R.C.4
  • 23
    • 34748860353 scopus 로고    scopus 로고
    • Intra-observer and interobserver reproducibility of right ventricle volumes, function and mass by cardiac magnetic resonance
    • Catalano O., Antonaci S., Opasich C., Moro G., Mussida M., Perotti M., et al. Intra-observer and interobserver reproducibility of right ventricle volumes, function and mass by cardiac magnetic resonance. J Cardiovasc Med (Hagerstown) 8 (2007) 807-814
    • (2007) J Cardiovasc Med (Hagerstown) , vol.8 , pp. 807-814
    • Catalano, O.1    Antonaci, S.2    Opasich, C.3    Moro, G.4    Mussida, M.5    Perotti, M.6
  • 24
    • 0038787546 scopus 로고    scopus 로고
    • Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging
    • Alfakih K., Plein S., Bloomer T., Jones T., Ridgway J., and Sivananthan M. Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging. J Magn Reson Imaging 18 (2003) 25-32
    • (2003) J Magn Reson Imaging , vol.18 , pp. 25-32
    • Alfakih, K.1    Plein, S.2    Bloomer, T.3    Jones, T.4    Ridgway, J.5    Sivananthan, M.6
  • 25
    • 0032321648 scopus 로고    scopus 로고
    • Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography. A validation study using magnetic resonance imaging
    • Fujimoto S., Mizuno R., Nakagawa Y., Dohi K., and Nakano H. Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography. A validation study using magnetic resonance imaging. Int J Card Imaging 14 (1998) 385-390
    • (1998) Int J Card Imaging , vol.14 , pp. 385-390
    • Fujimoto, S.1    Mizuno, R.2    Nakagawa, Y.3    Dohi, K.4    Nakano, H.5
  • 26
    • 0031816948 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic measurement of right ventricular volume in children with congenital heart disease validated by magnetic resonance imaging
    • Papavassiliou D.P., Parks W.J., Hopkins K.L., and Fyfe D.A. Three-dimensional echocardiographic measurement of right ventricular volume in children with congenital heart disease validated by magnetic resonance imaging. J Am Soc Echocardiogr 11 (1998) 770-777
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 770-777
    • Papavassiliou, D.P.1    Parks, W.J.2    Hopkins, K.L.3    Fyfe, D.A.4
  • 27
    • 0030827844 scopus 로고    scopus 로고
    • Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass
    • Vogel M., Gutberlet M., Dittrich S., Hosten N., and Lange P.E. Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass. Heart 78 (1997) 127-130
    • (1997) Heart , vol.78 , pp. 127-130
    • Vogel, M.1    Gutberlet, M.2    Dittrich, S.3    Hosten, N.4    Lange, P.E.5
  • 28
    • 41949120031 scopus 로고    scopus 로고
    • Matrix-array 3-dimensional echocardiographic assessment of volumes, mass, and ejection fraction in young pediatric patients with a functional single ventricle: a comparison study with cardiac magnetic resonance
    • Soriano B.D., Hoch M., Ithuralde A., Geva T., Powell A.J., Kussman B.D., et al. Matrix-array 3-dimensional echocardiographic assessment of volumes, mass, and ejection fraction in young pediatric patients with a functional single ventricle: a comparison study with cardiac magnetic resonance. Circulation 117 (2008) 1842-1848
    • (2008) Circulation , vol.117 , pp. 1842-1848
    • Soriano, B.D.1    Hoch, M.2    Ithuralde, A.3    Geva, T.4    Powell, A.J.5    Kussman, B.D.6
  • 29
    • 47349116645 scopus 로고    scopus 로고
    • Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error
    • Mor-Avi V., Jenkins C., Kuhl H.P., Nesser H.J., Marwick T., Franke A., et al. Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 1 (2008) 413-423
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 413-423
    • Mor-Avi, V.1    Jenkins, C.2    Kuhl, H.P.3    Nesser, H.J.4    Marwick, T.5    Franke, A.6
  • 30
    • 34548222736 scopus 로고    scopus 로고
    • Quantification of left ventricular volumes and function in patients with cardiomyopathies by real-time three-dimensional echocardiography: a head-to-head comparison between two different semiautomated endocardial border detection algorithms
    • Soliman O.I., Krenning B.J., Geleijnse M.L., Nemes A., Bosch J.G., van Geuns R.J., et al. Quantification of left ventricular volumes and function in patients with cardiomyopathies by real-time three-dimensional echocardiography: a head-to-head comparison between two different semiautomated endocardial border detection algorithms. J Am Soc Echocardiogr 20 (2007) 1042-1049
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 1042-1049
    • Soliman, O.I.1    Krenning, B.J.2    Geleijnse, M.L.3    Nemes, A.4    Bosch, J.G.5    van Geuns, R.J.6
  • 31
    • 33747892717 scopus 로고    scopus 로고
    • Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: comparison with magnetic resonance imaging and radionuclide ventriculography
    • Nesser H.J., Tkalec W., Patel A.R., Masani N.D., Niel J., Markt B., et al. Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: comparison with magnetic resonance imaging and radionuclide ventriculography. Echocardiography 23 (2006) 666-680
    • (2006) Echocardiography , vol.23 , pp. 666-680
    • Nesser, H.J.1    Tkalec, W.2    Patel, A.R.3    Masani, N.D.4    Niel, J.5    Markt, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.