메뉴 건너뛰기




Volumn 23, Issue 1, 2010, Pages 63-72

Electrophoresis poly(dimethylsiloxane)/glass chips with integrated active cooling for quantification of amino acids

Author keywords

Capillary electrophoresis separation; Joule heating; Lab on chip; Microfluidics; Temperature measurements

Indexed keywords

ACTIVE COOLING; BIOMEDICAL ANALYSIS; BUFFER SOLUTIONS; CAPILLARY ELECTROPHORESIS SEPARATION; COMPLEX MICROSTRUCTURES; COOLING FUNCTION; COOLING RATES; ELECTROPHEROGRAMS; GLASS CHIPS; HIGH ELECTRIC FIELDS; LAB-ON-CHIP; LOW COSTS; MICRO DEVICES; MICROFLUIDIC PLATFORMS; MICROFLUIDIC STRUCTURES; MINIATURIZED DEVICES; ON CURRENTS; POLYMER MICROFLUIDICS; POLYMER-BASED MICRODEVICES; SEPARATION EFFICIENCY; THIN GLASS;

EID: 75449092428     PISSN: 08916152     EISSN: 15210480     Source Type: Journal    
DOI: 10.1080/08916150903402740     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 21244454846 scopus 로고    scopus 로고
    • Recent advances in the application of capillary electrophoresis to neuroscience
    • P. R. Powell and A. C. Ewing, Recent Advances in the Application of Capillary Electrophoresis to Neuroscience, Anal. Bioanal. Chem., vol.382, pp. 581-591, 2005.
    • (2005) Anal. Bioanal. Chem. , vol.382 , pp. 581-591
    • Powell, P.R.1    Ewing, A.C.2
  • 2
    • 0036802462 scopus 로고    scopus 로고
    • In Vivo temporal sequence of rat striatal glutamate, aspartate and dopamine efflux during apomorphine, nomifensine, nmda and pdc in situ administration
    • L. Bert, S. Parrot, F. Robert., C. Desvignes, L. Denoroy, M. F. Suaud-Chagny, and B. Renaud, In Vivo Temporal Sequence of Rat Striatal Glutamate, Aspartate and Dopamine Efflux During Apomorphine, Nomifensine, NMDA and PDC in situ Administration, Neuropharmacol., vol.43, pp. 825-835, 2002.
    • (2002) Neuropharmacol. , vol.43 , pp. 825-835
    • Bert, L.1    Parrot, S.2    Robert, F.3    Desvignes, C.4    Denoroy, L.5    Suaud-Chagny, M.F.6    Renaud, B.7
  • 3
    • 38749100962 scopus 로고    scopus 로고
    • Electrophoresis PDMS/Glass chips with continuous on-chip derivatization and analysis of amino acids using naphthalene-2,3-dicarboxaldehyde as fluorogenic agent
    • O. Yassine, P. Morin, O. Dispagne, L. Renaud, L. Denoroy, P Kleimann, K. Faure, J.-L. Rocca, N. Ouaini, and R. Ferrigno, Electrophoresis PDMS/Glass Chips with Continuous On-Chip Derivatization and Analysis of Amino Acids Using Naphthalene-2,3-Dicarboxaldehyde as Fluorogenic Agent, Anal. Chem. Acta, vol.609, pp. 215-222, 2008.
    • (2008) Anal. Chem. Acta , vol.609 , pp. 215-222
    • Yassine, O.1    Morin, P.2    Dispagne, O.3    Renaud, L.4    Denoroy, L.5    Kleimann, P.6    Faure, K.7    Rocca, J.-L.8    Ouaini, N.9    Ferrigno, R.10
  • 4
    • 1242296941 scopus 로고    scopus 로고
    • Effect of joule heating on efficiency and performance for microchip-based and capillary-based electrophoretic separation systems: A closer look
    • N. J. Petersen, R. P. H. Nikolajsen, K. B. Mogensen, and J. P. Kutter, Effect of Joule Heating on Efficiency and Performance for Microchip-Based and Capillary-Based Electrophoretic Separation Systems: A Closer Look, Electrophoresis, vol.25, pp. 253-2659, 2004.
    • (2004) Electrophoresis , vol.25 , pp. 253-2659
    • Petersen, N.J.1    Nikolajsen, R.P.H.2    Mogensen, K.B.3    Kutter, J.P.4
  • 5
    • 0025102568 scopus 로고
    • Influence of buffer concentration, capillary internal diameter and forced-convection on resolution in capillary zone electrophoresis
    • H. T. Rasmussen and H. M. McNair, Influence of Buffer Concentration, Capillary Internal Diameter and Forced-Convection on Resolution in Capillary Zone Electrophoresis, J. Chromatogr., vol.516, pp. 223-231, 1990.
    • (1990) J. Chromatogr. , vol.516 , pp. 223-231
    • Rasmussen, H.T.1    McNair, H.M.2
  • 6
    • 0025997332 scopus 로고
    • Temperature elevations of the sample zone in free solution capillary electrophoresis under stacking conditions
    • A. Vinther and H. Soeberg, Temperature Elevations of the Sample Zone in Free Solution Capillary Electrophoresis under Stacking Conditions, J. Chrom., vol.559, pp. 27-42, 1991.
    • (1991) J. Chrom. , vol.559 , pp. 27-42
    • Vinther, A.1    Soeberg, H.2
  • 7
    • 0035449448 scopus 로고    scopus 로고
    • Temperature measurement in microfluidic systems using a temperature-dependent fluorescent dye
    • D. Ross, M. Gaitan, and L. E. Locascio, Temperature Measurement in Microfluidic Systems Using a Temperature-Dependent Fluorescent Dye, Anal. Chem., vol.73, pp. 4117-4123, 2001.
    • (2001) Anal. Chem. , vol.73 , pp. 4117-4123
    • Ross, D.1    Gaitan, M.2    Locascio, L.E.3
  • 8
    • 38349118300 scopus 로고    scopus 로고
    • Temperature measurement in microfluidic chips using photobleaching of a fluorescent thin film
    • L. Gui and C. L. Ren, Temperature Measurement in Microfluidic Chips Using Photobleaching of a Fluorescent Thin Film, Appl. Phys.Lett., vol.92, p. 024102, 2008.
    • (2008) Appl. Phys.Lett. , vol.92 , pp. 024102
    • Gui, L.1    Ren, C.L.2
  • 9
    • 0036121411 scopus 로고    scopus 로고
    • Quantification and evaluation of joule heating in on-chip capillary electrophoresis
    • K. Swinney and D. J. Bornhop, Quantification and Evaluation of Joule Heating in On-Chip Capillary Electrophoresis, Electrophoresis, vol.23, pp. 613-620, 2002.
    • (2002) Electrophoresis , vol.23 , pp. 613-620
    • Swinney, K.1    Bornhop, D.J.2
  • 10
    • 0036713549 scopus 로고    scopus 로고
    • On-line temperature-monitoring in a capillary electrochromatograph frit using microcoil nmr
    • M. E. Lacey, A. G. Webb, and J. V. Sweedler, On-Line Temperature- Monitoring in a Capillary Electrochromatograph Frit Using Microcoil NMR, Anal. Chem., vol.74, pp. 4583-4587, 2002.
    • (2002) Anal. Chem. , vol.74 , pp. 4583-4587
    • Lacey, M.E.1    Webb, A.G.2    Sweedler, J.V.3
  • 11
    • 0032403465 scopus 로고    scopus 로고
    • Rapid prototyping of microfluidic systems in poly(Ddimethylsiloxane)
    • D. C. Duffy, J. C. McDonald, O. J. A. Schueller, and G. M. Whitesides, Rapid Prototyping of Microfluidic Systems in Poly(Ddimethylsiloxane), Anal. Chem., vol.70, pp. 4974-4984, 1998.
    • (1998) Anal. Chem. , vol.70 , pp. 4974-4984
    • Duffy, D.C.1    McDonald, J.C.2    Schueller, O.J.A.3    Whitesides, G.M.4
  • 12
    • 34748902473 scopus 로고    scopus 로고
    • Fast prototyping using a dry film photoresist: Microfabrication of soft-lithography masters for microfluidic structures
    • K. Stephan., P. Pittet, L. Renaud, P. Kleimann, P. Morin, N. Ouaini, and R. Ferrigno, Fast Prototyping Using a Dry Film Photoresist: Microfabrication of Soft-Lithography Masters for Microfluidic Structures, J. Micromech. Microeng., vol.17, pp. N69-N74, 2007.
    • (2007) J. Micromech. Microeng. , vol.17
    • Stephan., K.1    Pittet, P.2    Renaud, L.3    Kleimann, P.4    Morin, P.5    Ouaini, N.6    Ferrigno, R.7
  • 13
    • 33749047409 scopus 로고    scopus 로고
    • PDMS microfluidic systems with integrated fluorescence detection application to amino acids separation
    • L. Renaud, P. Kleimann, O. Dispagne, L. Denoroy, P. Pittet, R. Ferigno, and P. Morin, PDMS Microfluidic Systems with Integrated Fluorescence Detection Application to Amino Acids Separation, La Houille Blanche, vol.4, pp. 45-59, 2006.
    • (2006) La Houille Blanche , vol.4 , pp. 45-59
    • Renaud, L.1    Kleimann, P.2    Dispagne, O.3    Denoroy, L.4    Pittet, P.5    Ferigno, R.6    Morin, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.