메뉴 건너뛰기




Volumn 37, Issue SUPPL., 2004, Pages 174-179

The feasibility of ST-segment monitoring with a subcutaneous device

Author keywords

Ischemia; monitoring; subcutaneous

Indexed keywords

BODY SURFACE; CALCULATION; CLINICAL ARTICLE; CONFERENCE PAPER; DEVICE; ELECTROCARDIOGRAM; ELECTRODE; FEASIBILITY STUDY; HEART ARREST; HEART ARRHYTHMIA; HUMAN; ISCHEMIA; MONITORING; PRIORITY JOURNAL; QRS COMPLEX; RISK ASSESSMENT; ST SEGMENT;

EID: 7544247942     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelectrocard.2004.08.053     Document Type: Conference Paper
Times cited : (7)

References (21)
  • 1
    • 0000311765 scopus 로고    scopus 로고
    • Multilead ST-segment monitoring in patients with acute coronary syndromes: A consensus statement for healthcare professionals: ST-segment Monitoring Practice Guideline International Working Group
    • Drew B.J., Krucoff M.W. Multilead ST-segment monitoring in patients with acute coronary syndromes: A consensus statement for healthcare professionals: ST-segment Monitoring Practice Guideline International Working Group. American J Crit Care. 8:1999;372
    • (1999) American J Crit Care , vol.8 , pp. 372
    • Drew, B.J.1    Krucoff, M.W.2
  • 2
    • 0034064704 scopus 로고    scopus 로고
    • Optimizing the initial 12-lead electrocardiographic diagnosis of acute myocardial infarction
    • Menown I.B., Mackenzie G., Adgey A.A. Optimizing the initial 12-lead electrocardiographic diagnosis of acute myocardial infarction. Eur Heart J. 21:2000;275
    • (2000) Eur Heart J , vol.21 , pp. 275
    • Menown, I.B.1    MacKenzie, G.2    Adgey, A.A.3
  • 3
    • 0026088381 scopus 로고
    • Assessment of myocardial ischemia by 12-lead electrocardiography and Frank vector system during coronary angioplasty: Value of a new orthogonal lead system for quantitative ST segment monitoring
    • Weyne A.E., De Buyzere M.L., Bauwens F.R., et al. Assessment of myocardial ischemia by 12-lead electrocardiography and Frank vector system during coronary angioplasty Value of a new orthogonal lead system for quantitative ST segment monitoring. J Am College Cardiol. 18:1991;1704
    • (1991) J Am College Cardiol , vol.18 , pp. 1704
    • Weyne, A.E.1    De Buyzere, M.L.2    Bauwens, F.R.3
  • 4
    • 0242668765 scopus 로고    scopus 로고
    • Long-term ST database: A reference for the development and evaluation of automated ischemia detectors and for the study of the dynamics of myocardial ischemia
    • Jager F., Taddei A., Moody G.B., et al. Long-term ST database a reference for the development and evaluation of automated ischemia detectors and for the study of the dynamics of myocardial ischemia. Medical Biol Eng Comput. 41:2003;172
    • (2003) Medical Biol Eng Comput , vol.41 , pp. 172
    • Jager, F.1    Taddei, A.2    Moody, G.B.3
  • 5
    • 1542650930 scopus 로고    scopus 로고
    • ST segment analysis by Holter Monitoring: Methodological considerations
    • Bjerregaard P., El-Shafei A., Kotar S.L., et al. ST segment analysis by Holter Monitoring Methodological considerations. Ann Noninvas Electrocardiol. 8:2003;200
    • (2003) Ann Noninvas Electrocardiol , vol.8 , pp. 200
    • Bjerregaard, P.1    El-Shafei, A.2    Kotar, S.L.3
  • 6
    • 0031762496 scopus 로고    scopus 로고
    • Detection of transient ST segment episodes during ambulatory ECG monitoring
    • Jager F., Moody G.B., Mark R.G. Detection of transient ST segment episodes during ambulatory ECG monitoring. Computers and Biomedical Research. 31:1998;305
    • (1998) Computers and Biomedical Research , vol.31 , pp. 305
    • Jager, F.1    Moody, G.B.2    Mark, R.G.3
  • 7
    • 0034232371 scopus 로고    scopus 로고
    • Reveal-investigators: Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder, Reveal-investigators
    • Seidl K., Rameken M., Breunung S., et al. Reveal-investigators Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder, Reveal-investigators. Europace. 2:2003;256
    • (2003) Europace , vol.2 , pp. 256
    • Seidl, K.1    Rameken, M.2    Breunung, S.3
  • 8
    • 7544225253 scopus 로고    scopus 로고
    • Analysis of electrocardiograms for subcutaneous monitors
    • Burke M.C., Song Z., Jenkins J., et al. Analysis of electrocardiograms for subcutaneous monitors. J Electrocardiol. 367:(suppl):2003;22
    • (2003) J Electrocardiol , vol.367 , Issue.SUPPL. , pp. 22
    • Burke, M.C.1    Song, Z.2    Jenkins, J.3
  • 9
    • 0017898175 scopus 로고
    • Limited lead selection for estimation of body surface potential maps in electrocardiography
    • Lux R.L., Smith C.R., Wyatt R.F., et al. Limited lead selection for estimation of body surface potential maps in electrocardiography. IEEE Trans Biomed Eng. 25:1978;270
    • (1978) IEEE Trans Biomed Eng , vol.25 , pp. 270
    • Lux, R.L.1    Smith, C.R.2    Wyatt, R.F.3
  • 10
    • 0018382421 scopus 로고
    • Clinically practical lead systems for improved electrocardiography: Comparison with precordial grids and conventional lead systems
    • Lux R.L., Burgess M.J., Wyatt R.F., et al. Clinically practical lead systems for improved electrocardiography Comparison with precordial grids and conventional lead systems. Circulation. 59:1979;356
    • (1979) Circulation , vol.59 , pp. 356
    • Lux, R.L.1    Burgess, M.J.2    Wyatt, R.F.3
  • 11
    • 0035696786 scopus 로고    scopus 로고
    • A real-time ST-segment monitoring algorithm for implantable devices
    • Stadler R.W., Lu S.N., Nelson S.D., Stylos L. A real-time ST-segment monitoring algorithm for implantable devices. J Electrocardiol. 34:(suppl):2001;119
    • (2001) J Electrocardiol , vol.34 , Issue.SUPPL. , pp. 119
    • Stadler, R.W.1    Lu, S.N.2    Nelson, S.D.3    Stylos, L.4
  • 12
    • 0036623834 scopus 로고    scopus 로고
    • Continuous multilead ST-segment monitoring should be a part of the clinical routine
    • Jernberg T., Lindahl B., Wallentin L. Continuous multilead ST-segment monitoring should be a part of the clinical routine. Eur Heart J. 23:2002;918
    • (2002) Eur Heart J , vol.23 , pp. 918
    • Jernberg, T.1    Lindahl, B.2    Wallentin, L.3
  • 13
    • 0032163901 scopus 로고    scopus 로고
    • 12-lead ST-segment monitoring vs. single lead maximum ST-segment monitoring for detecting ongoing ischemia in patients with unstable coronary syndromes
    • Drew B.J., Pelter M.M., Adams M.G., et al. 12-lead ST-segment monitoring vs. single lead maximum ST-segment monitoring for detecting ongoing ischemia in patients with unstable coronary syndromes. Am J Crit Care. 7:1998;355
    • (1998) Am J Crit Care , vol.7 , pp. 355
    • Drew, B.J.1    Pelter, M.M.2    Adams, M.G.3
  • 14
    • 0033783242 scopus 로고    scopus 로고
    • How can we identify the best implantation site for an ECG event recorder?
    • Zellerhoff C., Himmrich E., Nebeling D., et al. How can we identify the best implantation site for an ECG event recorder? PACE. 23:(Pt. I):2002;1545
    • (2002) PACE , vol.23 , Issue.1 PART , pp. 1545
    • Zellerhoff, C.1    Himmrich, E.2    Nebeling, D.3
  • 15
    • 0035700499 scopus 로고    scopus 로고
    • Optimal electrocardiographic leads for detecting acute myocardial ischemia
    • Horáček B.M., Warren J.W., Penney C.J., et al. Optimal electrocardiographic leads for detecting acute myocardial ischemia. J Electrocardiol. 34:(suppl):2001;97
    • (2001) J Electrocardiol , vol.34 , Issue.SUPPL. , pp. 97
    • Horáček, B.M.1    Warren, J.W.2    Penney, C.J.3
  • 16
    • 0027535365 scopus 로고
    • Body surface potential mapping of ST-segment shift in patients undergoing percutaneous transluminal coronary angioplasty: Correlations with the ECG and vectorcardiogram
    • Shenasa M., Hamel D., Nasmith J., et al. Body surface potential mapping of ST-segment shift in patients undergoing percutaneous transluminal coronary angioplasty Correlations with the ECG and vectorcardiogram. J Electrocardiol. 26:1993;43
    • (1993) J Electrocardiol , vol.26 , pp. 43
    • Shenasa, M.1    Hamel, D.2    Nasmith, J.3
  • 17
    • 4143063804 scopus 로고    scopus 로고
    • Comparison of alarm strategies for continuous 12-lead ST-segment monitoring
    • Wang J.Y., Saenz M.C., Horacek B.M. Comparison of alarm strategies for continuous 12-lead ST-segment monitoring. Computers in Cardiology. 30:2003;809
    • (2003) Computers in Cardiology , vol.30 , pp. 809
    • Wang, J.Y.1    Saenz, M.C.2    Horacek, B.M.3
  • 18
    • 0036159313 scopus 로고    scopus 로고
    • Multilead precordial ST-segment monitoring: The next generation?
    • London M.J. Multilead precordial ST-segment monitoring The next generation? Anesthesiology. 96:2002;259
    • (2002) Anesthesiology , vol.96 , pp. 259
    • London, M.J.1
  • 19
    • 0027638616 scopus 로고
    • ST-segment monitoring for coronary artery reocclusion following thrombolytic therapy and coronary angioplasty: Identification of optimal bedside monitoring leads
    • Drew B.J., Tisdale L.A. ST-segment monitoring for coronary artery reocclusion following thrombolytic therapy and coronary angioplasty Identification of optimal bedside monitoring leads. Am J Crit Care. 2:1993;280
    • (1993) Am J Crit Care , vol.2 , pp. 280
    • Drew, B.J.1    Tisdale, L.A.2
  • 20
    • 0036161874 scopus 로고    scopus 로고
    • Perioperative myocardial ischemia and infarction: Identification by continuous 12-lead electrocardiogram with on-line ST-segment monitoring
    • Landesberg G., Mosseri M., Wolf Y., et al. Perioperative myocardial ischemia and infarction Identification by continuous 12-lead electrocardiogram with on-line ST-segment monitoring. Anesthesiology. 96:2002;264
    • (2002) Anesthesiology , vol.96 , pp. 264
    • Landesberg, G.1    Mosseri, M.2    Wolf, Y.3
  • 21


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.