메뉴 건너뛰기




Volumn 52, Issue 5, 2004, Pages 1043-1051

Perfusion assessment with bolus differentiation: A technique applicable to hyperpolarized tracers

Author keywords

Arterial dispersion; Hyperpolarized carbon 13; Magnetic resonance imaging; Perfusion assessment; Renal cortex

Indexed keywords

DISPERSIONS; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; TISSUE; TRACERS;

EID: 7544220591     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20247     Document Type: Article
Times cited : (65)

References (36)
  • 4
    • 0035180810 scopus 로고    scopus 로고
    • On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
    • Kiselev VG. On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI. Magn Reson Med 2001;46:1113-1122.
    • (2001) Magn Reson Med , vol.46 , pp. 1113-1122
    • Kiselev, V.G.1
  • 5
    • 0034466075 scopus 로고    scopus 로고
    • The impact of peak saturation of the arterial input function on quantitative evaluation of dynamics susceptibility contrast-enhanced MR studies
    • Ellinger R, Kremser C, Schocke MF, Kolbitsch C, Griebel J, Felber SR, Aichner FT. The impact of peak saturation of the arterial input function on quantitative evaluation of dynamics susceptibility contrast-enhanced MR studies. J Comput Assist Tomogr 2000;24:942-948.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 942-948
    • Ellinger, R.1    Kremser, C.2    Schocke, M.F.3    Kolbitsch, C.4    Griebel, J.5    Felber, S.R.6    Aichner, F.T.7
  • 6
    • 0034491759 scopus 로고    scopus 로고
    • Analysis of input functions from different arterial branches with gamma variate functions and cluster analysis for quantitative blood volume measurements
    • Rausch M, Scheffler K, Rudin M, Radü EW. Analysis of input functions from different arterial branches with gamma variate functions and cluster analysis for quantitative blood volume measurements. Magn Reson Imaging 2000;18:1235-1243.
    • (2000) Magn Reson Imaging , vol.18 , pp. 1235-1243
    • Rausch, M.1    Scheffler, K.2    Rudin, M.3    Radü, E.W.4
  • 8
    • 0033653372 scopus 로고    scopus 로고
    • Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA
    • Vallée JP, Lazeyras F, Khan HG, Terrier F. Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA. Eur Radiol 2000;10:1245-1252.
    • (2000) Eur Radiol , vol.10 , pp. 1245-1252
    • Vallée, J.P.1    Lazeyras, F.2    Khan, H.G.3    Terrier, F.4
  • 9
    • 0034899813 scopus 로고    scopus 로고
    • Xenon-129 MR imaging and spectroscopy of rat brain using arterial delivery of hyperpolarized xenon in lipid emulsion
    • Duhamel G, Choquet P, Grillon E, Lamalle L, Leviel JL, Ziegler A, Constantinesco A. Xenon-129 MR imaging and spectroscopy of rat brain using arterial delivery of hyperpolarized xenon in lipid emulsion. Magn Reson Med 2001;46:208-212.
    • (2001) Magn Reson Med , vol.46 , pp. 208-212
    • Duhamel, G.1    Choquet, P.2    Grillon, E.3    Lamalle, L.4    Leviel, J.L.5    Ziegler, A.6    Constantinesco, A.7
  • 10
    • 0036337097 scopus 로고    scopus 로고
    • Hyperpolarized helium3 encapsulated in microbubbles: A new class of blood pool MRI contrast agent
    • Callot V, Canet E, Brochot J, Humblot H, Briguet A, Tournier H, Crémillieux Y. Hyperpolarized helium3 encapsulated in microbubbles: a new class of blood pool MRI contrast agent. Acad Radiol 2002;9(suppl 2):501-503.
    • (2002) Acad Radiol , vol.9 , Issue.2 SUPPL. , pp. 501-503
    • Callot, V.1    Canet, E.2    Brochot, J.3    Humblot, H.4    Briguet, A.5    Tournier, H.6    Crémillieux, Y.7
  • 14
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 15
    • 0036210186 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: A simulation study
    • Schmitt M, Viallon M, Thelen M, Schreiber WG. Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: a simulation study. Magn Reson Med 2002;47:787-793.
    • (2002) Magn Reson Med , vol.47 , pp. 787-793
    • Schmitt, M.1    Viallon, M.2    Thelen, M.3    Schreiber, W.G.4
  • 16
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 18
    • 0037310235 scopus 로고    scopus 로고
    • Quantification of renal perfusion using an intravascular contrast agent (part 1): Results in a canine model
    • Aumann S, Schoenberg SO, Just A, Briley-Saebo K, Bjørnerud A, Bock M, Brix G. Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model. Magn Reson Med 2003;49:276-287.
    • (2003) Magn Reson Med , vol.49 , pp. 276-287
    • Aumann, S.1    Schoenberg, S.O.2    Just, A.3    Briley-Saebo, K.4    Bjørnerud, A.5    Bock, M.6    Brix, G.7
  • 19
    • 7544234693 scopus 로고
    • Areas of dye-dilution curves sampled simultaneously from central and peripheral sites
    • Bassingthwaighte JB, Edwards AWT, Wood EH. Areas of dye-dilution curves sampled simultaneously from central and peripheral sites. J Appl Physiol 1962;17:91-98.
    • (1962) J Appl Physiol , vol.17 , pp. 91-98
    • Bassingthwaighte, J.B.1    Edwards, A.W.T.2    Wood, E.H.3
  • 20
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography: Theoretical analysis
    • Axel L. Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. Radiology 1980;137:679-686.
    • (1980) Radiology , vol.137 , pp. 679-686
    • Axel, L.1
  • 21
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 1995;34:910-914.
    • (1995) Magn Reson Med , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 23
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998;97:473-483.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 24
    • 0034053804 scopus 로고    scopus 로고
    • Spin echo entrapped perfusion image (SEEPAGE). A nonsubtraction method for direct imaging of perfusion
    • Blamire AM, Styles P. Spin echo entrapped perfusion image (SEEPAGE). A nonsubtraction method for direct imaging of perfusion. Magn Reson Med 2000;43:701-704.
    • (2000) Magn Reson Med , vol.43 , pp. 701-704
    • Blamire, A.M.1    Styles, P.2
  • 25
    • 0025222891 scopus 로고
    • Noise correlations in data simultaneously acquired from multiple surface coil arrays
    • Hayes CE, Roemer PB. Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn Reson Med 1990;16:181-191.
    • (1990) Magn Reson Med , vol.16 , pp. 181-191
    • Hayes, C.E.1    Roemer, P.B.2
  • 26
    • 0031905316 scopus 로고    scopus 로고
    • Renal cortical ischemia in rabbits revealed by contrast-enhanced power Doppler sonography
    • Taylor GA, Barnewolt CE, Adler BH, Dunning PS. Renal cortical ischemia in rabbits revealed by contrast-enhanced power Doppler sonography. AJR Am J Roentgenol 1998;170:417-422.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 417-422
    • Taylor, G.A.1    Barnewolt, C.E.2    Adler, B.H.3    Dunning, P.S.4
  • 27
    • 0013939657 scopus 로고
    • Plasma indicator dispersion in arteries of the human leg
    • Bassingthwaighte JB. Plasma indicator dispersion in arteries of the human leg. Circ Res 1966;19:332-346.
    • (1966) Circ Res , vol.19 , pp. 332-346
    • Bassingthwaighte, J.B.1
  • 28
    • 0000924188 scopus 로고
    • Theory of the measurement of the dispersion of an indicator in indicator-dilution studies
    • Gonzalez-Fernandez JM. Theory of the measurement of the dispersion of an indicator in indicator-dilution studies. Circ Res 1962;10:409-428.
    • (1962) Circ Res , vol.10 , pp. 409-428
    • Gonzalez-Fernandez, J.M.1
  • 30
    • 44349129408 scopus 로고
    • The theory and applications of the exchange of inert gas at the lungs and tissues
    • Kety SS. The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol Rev 1951;3:1-41.
    • (1951) Pharmacol Rev , vol.3 , pp. 1-41
    • Kety, S.S.1
  • 32
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193:637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gückel, F.5    Lorenz, W.J.6
  • 33
    • 0024360873 scopus 로고
    • 15O autoradiographic method and dynamic PET
    • 15O autoradiographic method and dynamic PET. J Nucl Med 1989;30:1069-1078.
    • (1989) J Nucl Med , vol.30 , pp. 1069-1078
    • Meyer, E.1
  • 36
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 2003;19:341-353.
    • (2003) Neuroimage , vol.19 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.