-
1
-
-
0023937536
-
High inflation pressure pulmonary edema: Respective effects of high airway pressure, high VT, and positive end-expiratory pressure
-
Dreyfuss D, Soler P, Basset G, et al: High inflation pressure pulmonary edema: Respective effects of high airway pressure, high VT, and positive end-expiratory pressure. Am Rev Respir Dis 1988; 137:1159-1164
-
(1988)
Am Rev Respir Dis
, vol.137
, pp. 1159-1164
-
-
Dreyfuss, D.1
Soler, P.2
Basset, G.3
-
2
-
-
0343893748
-
Ventilation with lower VTs as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
-
The Acute Respiratory Distress Syndrome Network
-
The Acute Respiratory Distress Syndrome Network: Ventilation with lower VTs as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342: 1301-1308
-
(2000)
N Engl J Med
, vol.342
, pp. 1301-1308
-
-
-
3
-
-
0028796852
-
Acute respiratory distress syndrome in pediatric patients: Redirecting therapy to reduce iatrogenic lung injury
-
Heulitt M, Anders M, Benham D: Acute respiratory distress syndrome in pediatric patients: Redirecting therapy to reduce iatrogenic lung injury. Respir Care 1995; 40: 74-85
-
(1995)
Respir Care
, vol.40
, pp. 74-85
-
-
Heulitt, M.1
Anders, M.2
Benham, D.3
-
4
-
-
0032447601
-
Lung-protective strategy in pediatric patients with acute respiratory distress syndrome
-
Heulitt M, Bohn D: Lung-protective strategy in pediatric patients with acute respiratory distress syndrome. Respir Care 1998; 43: 952-960 (Pubitemid 29018796)
-
(1998)
Respiratory Care
, vol.43
, Issue.11
, pp. 952-960
-
-
Heulitt, M.J.1
Bohn, D.2
-
5
-
-
0034518917
-
Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube
-
Cannon ML, Cornell J, Tripp-Hamel DS, et al: Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube. Am J Respir Crit Care Med 2000; 162: 2109-2112
-
(2000)
Am J Respir Crit Care Med
, vol.162
, pp. 2109-2112
-
-
Cannon, M.L.1
Cornell, J.2
Tripp-Hamel, D.S.3
-
6
-
-
0036852034
-
Accuracy of displayed values of tidal volume in the pediatric intensive care unit
-
Castle RA, Dunne CJ, Mok Q, et al: Accuracy of displayed values of tidal volume in the pediatric intensive care unit. Crit Care Med 2002; 30:2566-2574
-
(2002)
Crit Care Med
, vol.30
, pp. 2566-2574
-
-
Castle, R.A.1
Dunne, C.J.2
Mok, Q.3
-
7
-
-
2142669394
-
Influence of respiratory system impedance on volume and pressure delivered at the y piece in ventilated infants
-
Nève V, Leclerc F, Noizet O, et al: Influence of respiratory system impedance on volume and pressure delivered at the Y piece in ventilated infants. Pediatr Crit Care Med 2003; 4:418-425
-
(2003)
Pediatr Crit Care Med
, vol.4
, pp. 418-425
-
-
Nève, V.1
Leclerc, F.2
Noizet, O.3
-
8
-
-
0030611261
-
Changes in TcPCO2 regarding pulmonary mechanics due to pneumotachometer dead space in ventilated newborns
-
Figueras J, Rodriguez-Miguelez J, Botet F, et al: Changes in TcPCO2 regarding pulmonary mechanics due to pneumotachometer dead space in ventilated newborns. J Perinat Med 1997; 25:333-339
-
(1997)
J Perinat Med
, vol.25
, pp. 333-339
-
-
Figueras, J.1
Rodriguez-Miguelez, J.2
Botet, F.3
-
9
-
-
29244488512
-
The influence of flow rate on breathing circuit compliance and tidal volume delivered to patients in mechanical ventilation
-
Silvestri S: The influence of flow rate on breathing circuit compliance and tidal volume delivered to patients in mechanical ventilation. Physiol Meas 2006; 27:23-33
-
(2006)
Physiol Meas
, vol.27
, pp. 23-33
-
-
Silvestri, S.1
-
10
-
-
25144495565
-
Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs
-
Heulitt MJ, Holt SJ, Thurman TL, et al: Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs. Intensive Care Med 2005; 3:1255-1261
-
(2005)
Intensive Care Med
, vol.3
, pp. 1255-1261
-
-
Heulitt, M.J.1
Holt, S.J.2
Thurman, T.L.3
-
12
-
-
0017360990
-
The measurement of observer agreement for categorical data
-
Landis JR, Koch CG: The measurement of observer agreement for categorical data. Biometrics 1977; 33:159-174
-
(1977)
Biometrics
, vol.33
, pp. 159-174
-
-
Landis, J.R.1
Koch, C.G.2
-
13
-
-
0034863226
-
Modeling concordance correlation via GEE to evaluate reproducibility
-
Barnhart H, Williamson J: Modeling concordance correlation via GEE to evaluate reproducibility. Biometrics 2001; 57:931-940
-
(2001)
Biometrics
, vol.57
, pp. 931-940
-
-
Barnhart, H.1
Williamson, J.2
-
14
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; I:307-310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
15
-
-
28744451104
-
The concepts of bias, precision and accuracy, and their use in testing the performance of species richness estimators, with literature review of estimator performance
-
Walther B, Moore J: The concepts of bias, precision and accuracy, and their use in testing the performance of species richness estimators, with literature review of estimator performance. Ecography 2005; 28:815-819
-
(2005)
Ecography
, vol.28
, pp. 815-819
-
-
Walther, B.1
Moore, J.2
-
16
-
-
0024726979
-
Analysis of the dynamic characteristics of pressure transducers for studying respiratory mechanics at high frequencies
-
Farre R, Peslin R, Navajas D, et al: Analysis of the dynamic characteristics of pressure transducers for studying respiratory mechanics at high frequencies. Med Biol Eng Comput 1989; 27:531-537
-
(1989)
Med Biol Eng Comput
, vol.27
, pp. 531-537
-
-
Farre, R.1
Peslin, R.2
Navajas, D.3
-
17
-
-
27144506133
-
Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume
-
Al-Majed S, Thompson JE, Watson KF, et al: Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume. Crit Care 2004; 8:R398-R402
-
(2004)
Crit Care
, vol.8
-
-
Al-Majed, S.1
Thompson, J.E.2
Watson, K.F.3
-
18
-
-
30344468126
-
Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator
-
Cappa P, Sciuto A, Silvestri S: Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. J Med Eng Technol 2006; 30:31-40
-
(2006)
J Med Eng Technol
, vol.30
, pp. 31-40
-
-
Cappa, P.1
Sciuto, A.2
Silvestri, S.3
-
19
-
-
75149120151
-
Monitoring during mechanical ventilation
-
Second Edition. Tobin MJ (Ed). New York, McGraw Hill
-
Jubran A, Tobin M: Monitoring during mechanical ventilation. In: Principles and Practice of Mechanical Ventilation. Second Edition. Tobin MJ (Ed). New York, McGraw Hill, 2006, pp 1051-1080
-
(2006)
Principles and Practice of Mechanical Ventilation
, pp. 1051-1080
-
-
Jubran, A.1
Tobin, M.2
|