Volumn 31, Issue 9, 2005, Pages 1255-1261

Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs

Author keywords

Lung volume measurements; Mechanical ventilation; Reproducibility of results; Respiratory physiology

Indexed keywords

AIRWAY CONDUCTANCE; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; ARTIFICIAL VENTILATION; COMPUTER PROGRAM; CONTROLLED STUDY; CORRELATION COEFFICIENT; EXPIRATORY RESERVE VOLUME; INTERMETHOD COMPARISON; LUNG COMPLIANCE; LUNG FUNCTION; LUNG VOLUME; NONHUMAN; POSITIVE END EXPIRATORY PRESSURE; RELIABILITY; SWINE; TIDAL VOLUME; VENTILATOR;

EID: 25144495565     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-005-2717-y     Document Type: Article
Times cited : (18)

References (13)
  • 1
    • 0026451394 scopus 로고
    • Barotrauma is volutrauma, but which volume is the one responsible?
    • Dreyfuss D, Saumon G (1992) Barotrauma is volutrauma, but which volume is the one responsible? Intensive Care Med 18:139-141
    • (1992) Intensive Care Med , vol.18 , pp. 139-141
    • Dreyfuss, D.1    Saumon, G.2
  • 2
    • 0028796852 scopus 로고
    • Acute respiratory distress syndrome in pediatric patients: Redirecting therapy to reduce iatrogenic lung injury
    • Heulitt MJ, Anders M, Benham D (1995) Acute respiratory distress syndrome in pediatric patients: redirecting therapy to reduce iatrogenic lung injury. Respir Care 40:74-85
    • (1995) Respir Care , vol.40 , pp. 74-85
    • Heulitt, M.J.1    Anders, M.2    Benham, D.3
  • 3
    • 0032447601 scopus 로고    scopus 로고
    • Lung-protective strategy in pediatric patients with acute respiratory distress syndrome
    • Heulitt MJ, Bohn D (1998) Lung-protective strategy in pediatric patients with acute respiratory distress syndrome. Respir Care 43:952-960
    • (1998) Respir Care , vol.43 , pp. 952-960
    • Heulitt, M.J.1    Bohn, D.2
  • 5
    • 0036852034 scopus 로고    scopus 로고
    • Accuracy of displayed values of tidal volume in the pediatric intensive care unit
    • Castle RA, Dunne CJ, Mok Q, Wade AM, Stocks J (2002) Accuracy of displayed values of tidal volume in the pediatric intensive care unit. Crit Care Med 30:2566-2574
    • (2002) Crit Care Med , vol.30 , pp. 2566-2574
    • Castle, R.A.1    Dunne, C.J.2    Mok, Q.3    Wade, A.M.4    Stocks, J.5
  • 6
    • 0141727744 scopus 로고    scopus 로고
    • Elimination of ventilator dead space during synchronized ventilation in premature infants
    • Claure N, D'Ugard C, Bancalari E (2003) Elimination of ventilator dead space during synchronized ventilation in premature infants. J Pediatr 143:315-320
    • (2003) J Pediatr , vol.143 , pp. 315-320
    • Claure, N.1    D'Ugard, C.2    Bancalari, E.3
  • 7
    • 70449499005 scopus 로고
    • Guide for the care and use of laboratory animals
    • National Institutes of Health (1985) Guide for the care and use of laboratory animals. NIH publication no 86-23
    • (1985) NIH Publication No 86-23
  • 8
    • 0029927989 scopus 로고    scopus 로고
    • A weighted concordance correlation coefficient for repeated measurement designs
    • Chinchilli V, Martel J, Kumanyika S, Lloyd T (1996) A weighted concordance correlation coefficient for repeated measurement designs. Biometrics 52:341-353
    • (1996) Biometrics , vol.52 , pp. 341-353
    • Chinchilli, V.1    Martel, J.2    Kumanyika, S.3    Lloyd, T.4
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135-160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0035112952 scopus 로고    scopus 로고
    • Deadspace free ventilatory measurements in newborns during mechanical ventilation
    • Foitzik BD, Schmidt MD, Proquitte H, Schmalisch GD (2001) Deadspace free ventilatory measurements in newborns during mechanical ventilation. Crit Care Med 29:413-419
    • (2001) Crit Care Med , vol.29 , pp. 413-419
    • Foitzik, B.D.1    Schmidt, M.D.2    Proquitte, H.3    Schmalisch, G.D.4
  • 13
    • 0032147673 scopus 로고    scopus 로고
    • Accuracy of volume measurements in mechanically ventilated newborns: A comparative study of commercial devices
    • Roske K, Foitzik B, Wauer RR, Schmalisch G (1998) Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices. J Clin Monit Comput 14:413-420
    • (1998) J Clin Monit Comput , vol.14 , pp. 413-420
    • Roske, K.1    Foitzik, B.2    Wauer, R.R.3    Schmalisch, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.