메뉴 건너뛰기




Volumn 45, Issue 2, 2010, Pages 72-76

Assessment of left atrial volumes and function in orthotopic heart transplant recipients by dual-source CT: Comparison with MRI

Author keywords

Computed tomography; Function; Heart transplantation; Magnetic resonance imaging

Indexed keywords

IOMEPROL;

EID: 74949089253     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181c4f535     Document Type: Article
Times cited : (14)

References (34)
  • 1
    • 50249098729 scopus 로고    scopus 로고
    • Registry of the International Society for Heart and Lung Transplantation: Twenty-fifth official adult heart transplant report-2008
    • Taylor DO, Edwards LB, Aurora P, et al. Registry of the International Society for Heart and Lung Transplantation: twenty-fifth official adult heart transplant report-2008. J Heart Lung Transplant. 2008;27:943-956.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 943-956
    • Taylor, D.O.1    Edwards, L.B.2    Aurora, P.3
  • 3
    • 0025779618 scopus 로고
    • Frequency and mechanism of bradycardia in cardiac transplant recipients and need for pacemakers
    • DiBiase A, Tse TM, Schnittger I, et al. Frequency and mechanism of bradycardia in cardiac transplant recipients and need for pacemakers. Am J Cardiol. 1991;67:1385-1389.
    • (1991) Am J Cardiol , vol.67 , pp. 1385-1389
    • Dibiase, A.1    Tse, T.M.2    Schnittger, I.3
  • 4
    • 0034943460 scopus 로고    scopus 로고
    • Severe tricuspid regurgitation after heart transplantation
    • Chan MC, Giannetti N, Kato T, et al. Severe tricuspid regurgitation after heart transplantation. J Heart Lung Transplant. 2001;20:709-717.
    • (2001) J Heart Lung Transplant , vol.20 , pp. 709-717
    • Chan, M.C.1    Giannetti, N.2    Kato, T.3
  • 5
    • 0028925825 scopus 로고
    • High incidence of left atrial thrombus detected by transoesophageal echocardiography in heart transplant recipients
    • Derumeaux G, Mouton-Schleifer D, Soyer R, et al. High incidence of left atrial thrombus detected by transoesophageal echocardiography in heart transplant recipients. Eur Heart J. 1995;16:120-125.
    • (1995) Eur Heart J , vol.16 , pp. 120-125
    • Derumeaux, G.1    Mouton-Schleifer, D.2    Soyer, R.3
  • 6
    • 0025803537 scopus 로고
    • An alternative technique for orthotopic cardiac transplantation, with preservation of the normal anatomy of the right atrium
    • Sievers HH, Weyand M, Kraatz EG, et al. An alternative technique for orthotopic cardiac transplantation, with preservation of the normal anatomy of the right atrium. Thorac Cardiovasc Surg. 1991;39:70-72.
    • (1991) Thorac Cardiovasc Surg , vol.39 , pp. 70-72
    • Sievers, H.H.1    Weyand, M.2    Kraatz, E.G.3
  • 7
    • 0027213177 scopus 로고
    • An alternative surgical technique in orthotopic cardiac transplantation
    • Sarsam MA, Campbell CS, Yonan NA, et al. An alternative surgical technique in orthotopic cardiac transplantation. J Card Surg. 1993;8:344-349.
    • (1993) J Card Surg , vol.8 , pp. 344-349
    • Sarsam, M.A.1    Campbell, C.S.2    Yonan, N.A.3
  • 8
    • 0026054645 scopus 로고
    • Total orthotopic heart transplantation: An alternative to the standard technique
    • Dreyfus G, Jebara V, Mihaileanu S, et al. Total orthotopic heart transplantation: an alternative to the standard technique. Ann Thorac Surg. 1991;52: 1181-1184.
    • (1991) Ann Thorac Surg , vol.52 , pp. 1181-1184
    • Dreyfus, G.1    Jebara, V.2    Mihaileanu, S.3
  • 9
    • 0028960601 scopus 로고
    • Atrial emptying with orthotopic heart transplantation using bicaval and pulmonary venous anastomoses: A magnetic resonance imaging study
    • Freimark D, Silverman JM, Aleksic I, et al. Atrial emptying with orthotopic heart transplantation using bicaval and pulmonary venous anastomoses: a magnetic resonance imaging study. J Am Coll Cardiol. 1995;25:932-936.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 932-936
    • Freimark, D.1    Silverman, J.M.2    Aleksic, I.3
  • 10
    • 0031763465 scopus 로고    scopus 로고
    • The bicaval anastomosis technique for orthotopic heart transplantation yields better atrial function than the standard technique: An echocardiographic automatic boundary detection study
    • Traversi E, Pozzoli M, Grande A, et al. The bicaval anastomosis technique for orthotopic heart transplantation yields better atrial function than the standard technique: an echocardiographic automatic boundary detection study. J Heart Lung Transplant. 1998;17:1065-1074.
    • (1998) J Heart Lung Transplant , vol.17 , pp. 1065-1074
    • Traversi, E.1    Pozzoli, M.2    Grande, A.3
  • 11
    • 35448937192 scopus 로고    scopus 로고
    • Bicaval versus standard technique in orthotopic heart transplantation: A systematic review and meta-analysis
    • Schnoor M, Schafer T, Luhmann D, et al. Bicaval versus standard technique in orthotopic heart transplantation: a systematic review and meta-analysis. J Thorac Cardiovasc Surg. 2007;134:1322-1331.
    • (2007) J Thorac Cardiovasc Surg , vol.134 , pp. 1322-1331
    • Schnoor, M.1    Schafer, T.2    Luhmann, D.3
  • 12
    • 37149007757 scopus 로고    scopus 로고
    • Influence of different implantation techniques on long-term survival after orthotopic heart transplantation: An echocardiographic study
    • Sun JP, Niu J, Banbury MK, et al. Influence of different implantation techniques on long-term survival after orthotopic heart transplantation: an echocardiographic study. J Heart Lung Transplant. 2007;26:1243-1248.
    • (2007) J Heart Lung Transplant , vol.26 , pp. 1243-1248
    • Sun, J.P.1    Niu, J.2    Banbury, M.K.3
  • 13
    • 39749169609 scopus 로고    scopus 로고
    • Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients
    • Mondillo S, Maccherini M, Galderisi M. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients. Cardio-vasc Ultrasound. 2008;6:2.
    • (2008) Cardio-vasc Ultrasound , vol.6 , pp. 2
    • Mondillo, S.1    MacCherini, M.2    Galderisi, M.3
  • 14
    • 34247127374 scopus 로고    scopus 로고
    • Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography
    • Ferencik M, Gregory SA, Butler J, et al. Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography. J Heart Lung Transplant. 2007;26:478-484.
    • (2007) J Heart Lung Transplant , vol.26 , pp. 478-484
    • Ferencik, M.1    Gregory, S.A.2    Butler, J.3
  • 15
    • 33748753585 scopus 로고    scopus 로고
    • Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary an-giography with intravascular ultrasound for the detection of transplant vas-culopathy
    • Gregory SA, Ferencik M, Achenbach S, et al. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary an-giography with intravascular ultrasound for the detection of transplant vas-culopathy. Am J Cardiol. 2006;98:877-884.
    • (2006) Am J Cardiol , vol.98 , pp. 877-884
    • Gregory, S.A.1    Ferencik, M.2    Achenbach, S.3
  • 16
    • 56949085750 scopus 로고    scopus 로고
    • Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: A comparative study with conventional coronary angiography
    • von Ziegler F, Leber AW, Becker A, et al. Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography. Int J Cardiovasc Imaging. 2009;25:91-100.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 91-100
    • Von Ziegler, F.1    Leber, A.W.2    Becker, A.3
  • 17
    • 49049105145 scopus 로고    scopus 로고
    • Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: Initial clinical experience
    • Bastarrika G, Arraiza M, De Cecco CN, et al. Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience. Eur Radiol. 2008;18:1784-1790.
    • (2008) Eur Radiol , vol.18 , pp. 1784-1790
    • Bastarrika, G.1    Arraiza, M.2    De Cecco, C.N.3
  • 18
    • 49149120080 scopus 로고    scopus 로고
    • Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates
    • Bastarrika G, De Cecco CN, Arraiza M, et al. Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates. AJR Am J Roentgenol. 2008;191:448-454.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 448-454
    • Bastarrika, G.1    De Cecco, C.N.2    Arraiza, M.3
  • 19
    • 49049111796 scopus 로고    scopus 로고
    • Dual-source CT coronary imaging in heart transplant recipients: Image quality and optimal reconstruction interval
    • Bastarrika G, De Cecco CN, Arraiza M, et al. Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval. Eur Radiol. 2008;18:1791-1799.
    • (2008) Eur Radiol , vol.18 , pp. 1791-1799
    • Bastarrika, G.1    De Cecco, C.N.2    Arraiza, M.3
  • 20
    • 65649085933 scopus 로고    scopus 로고
    • Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy
    • Mastrobuoni S, Bastarrika G, Ubilla M, et al. Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy. Transplantation. 2009;87:587-590.
    • (2009) Transplantation , vol.87 , pp. 587-590
    • Mastrobuoni, S.1    Bastarrika, G.2    Ubilla, M.3
  • 21
    • 42449100050 scopus 로고    scopus 로고
    • Left ventricular and left atrial dimensions and volumes: Comparison between dual-source CT and echocar-diography
    • Stolzmann P, Scheffel H, Trindade PT, et al. Left ventricular and left atrial dimensions and volumes: comparison between dual-source CT and echocar-diography. Invest Radiol. 2008;43:284-289.
    • (2008) Invest Radiol , vol.43 , pp. 284-289
    • Stolzmann, P.1    Scheffel, H.2    Trindade, P.T.3
  • 22
    • 28844478451 scopus 로고    scopus 로고
    • Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging
    • Hudsmith LE, Petersen SE, Francis JM, et al. Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging. J Cardiovasc Magn Reson. 2005;7:775-782.
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 775-782
    • Hudsmith, L.E.1    Petersen, S.E.2    Francis, J.M.3
  • 23
    • 0014125885 scopus 로고
    • Calculation of right and left cardiac ventricular volumes. Method using standard computer equipment and biplane angiocardiograms
    • Goerke RJ, Carlsson E. Calculation of right and left cardiac ventricular volumes. Method using standard computer equipment and biplane angiocardiograms. Invest Radiol. 1967;2:360-367.
    • (1967) Invest Radiol , vol.2 , pp. 360-367
    • Goerke, R.J.1    Carlsson, E.2
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 26
    • 59249087158 scopus 로고    scopus 로고
    • Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI
    • van der Vleuten PA, de Jonge GJ, Lubbers DD, et al. Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI. Eur Radiol. 2009;19:271-277.
    • (2009) Eur Radiol , vol.19 , pp. 271-277
    • Van Der Vleuten, P.A.1    De Jonge, G.J.2    Lubbers, D.D.3
  • 27
    • 35649008388 scopus 로고    scopus 로고
    • Dual-source CT with improved temporal resolution in assessment of left ventricular function: A pilot study
    • Brodoefel H, Kramer U, Reimann A, et al. Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study. AJR Am J Roentgenol. 2007;189:1064-1070.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 1064-1070
    • Brodoefel, H.1    Kramer, U.2    Reimann, A.3
  • 28
    • 4143108001 scopus 로고    scopus 로고
    • Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    • Jenkins C, Bricknell K, Hanekom L, et al. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol. 2004;44:878-886.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 878-886
    • Jenkins, C.1    Bricknell, K.2    Hanekom, L.3
  • 29
    • 0029011501 scopus 로고
    • Cardiovascular dynamics and dimensions after bicaval and standard cardiac transplantation
    • Leyh RG, Jahnke AW, Kraatz EG, et al. Cardiovascular dynamics and dimensions after bicaval and standard cardiac transplantation. Ann Thorac Surg. 1995;59:1495-1500.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1495-1500
    • Leyh, R.G.1    Jahnke, A.W.2    Kraatz, E.G.3
  • 30
    • 17344386038 scopus 로고    scopus 로고
    • Clinical experience with one hundred consecutive patients undergoing orthotopic heart transplantation with bicaval and pulmonary venous anastomoses
    • discussion 1502-1593
    • Trento A, Takkenberg JM, Czer LS, et al. Clinical experience with one hundred consecutive patients undergoing orthotopic heart transplantation with bicaval and pulmonary venous anastomoses. J Thorac Cardiovasc Surg. 1996;112:1496-1502, discussion 1502-1593.
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 1496-1502
    • Trento, A.1    Takkenberg, J.M.2    Czer, L.S.3
  • 31
    • 58149316317 scopus 로고    scopus 로고
    • Diagnostic accuracy of cardiac 64-slice computed tomography in detecting atrial thrombi. Comparative study with transesophageal echocardiography and cardiac surgery
    • Feuchtner GM, Dichtl W, Bonatti JO, et al. Diagnostic accuracy of cardiac 64-slice computed tomography in detecting atrial thrombi. Comparative study with transesophageal echocardiography and cardiac surgery. Invest Radiol. 2008;43:794-801.
    • (2008) Invest Radiol , vol.43 , pp. 794-801
    • Feuchtner, G.M.1    Dichtl, W.2    Bonatti, J.O.3
  • 32
    • 52049124017 scopus 로고    scopus 로고
    • Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: Comparison of manual and semiautomatic segmentation algorithms
    • Bastarrika G, Arraiza M, Pueyo JC, et al. Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms. Eur Radiol. 2008;18: 939-946.
    • (2008) Eur Radiol , vol.18 , pp. 939-946
    • Bastarrika, G.1    Arraiza, M.2    Pueyo, J.C.3
  • 33
    • 68449092611 scopus 로고    scopus 로고
    • Comparison of manual, semi-and fully automated heart segmentation for assessing global left ventricular function in multidetector computed tomography
    • Plumhans C, Keil S, Ocklenburg C, et al. Comparison of manual, semi-and fully automated heart segmentation for assessing global left ventricular function in multidetector computed tomography. Invest Radiol. 2009;44:476-482.
    • (2009) Invest Radiol , vol.44 , pp. 476-482
    • Plumhans, C.1    Keil, S.2    Ocklenburg, C.3
  • 34
    • 0028362878 scopus 로고
    • Assessment of left atrial volumes and phasic function using cine magnetic resonance imaging in normal subjects
    • Jarvinen V, Kupari M, Hekali P, et al. Assessment of left atrial volumes and phasic function using cine magnetic resonance imaging in normal subjects. Am J Cardiol. 1994;73:1135-1138.
    • (1994) Am J Cardiol , vol.73 , pp. 1135-1138
    • Jarvinen, V.1    Kupari, M.2    Hekali, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.