메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Local vs. Wide-area undervoltage load shedding in the presence of induction motor loads

Author keywords

Distributed control; Induction motors; Long term voltage instability; Undervoltage load shedding; Wide area protection

Indexed keywords

DISTRIBUTED CONTROL; DISTRIBUTED LOADS; LOAD-SHEDDING; LONG-TERM VOLTAGE INSTABILITY; OVEREXCITATION; TEST SYSTEMS; TIME SIMULATIONS; UNDER-VOLTAGE LOAD SHEDDING; WIDE AREA; WIDE AREA PROTECTION;

EID: 74949086960     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PTC.2009.5282247     Document Type: Conference Paper
Times cited : (11)

References (13)
  • 1
    • 0026850554 scopus 로고
    • Concepts of undervoltage load shedding for voltage stability
    • C. W. Taylor, "Concepts of undervoltage load shedding for voltage stability", IEEE Trans. on Power Delivery, Vol. 7, 1992, pp. 480-488.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , pp. 480-488
    • Taylor, C.W.1
  • 4
    • 43849093811 scopus 로고    scopus 로고
    • Design strategies for load-shedding schemes against voltage collapse in the hellenic system
    • May
    • V.C. Nikolaidis, C.D. Vournas, "Design Strategies for Load-Shedding Schemes against Voltage Collapse in the Hellenic System," IEEE Trans. Power Syst., Vol. 23, No. 2, May 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.2
    • Nikolaidis, V.C.1    Vournas, C.D.2
  • 5
    • 36348964610 scopus 로고    scopus 로고
    • Special protection scheme against voltage collapse in the South part of the Swedish grid
    • Paper No 38-103
    • B. Ingelsson, P. Lindström, D. Karlsson, G. Runvik, J. Sjödin, "Special Protection Scheme against Voltage Collapse in the South Part of the Swedish Grid," Proc. CIGRE Conference, 1996, Paper No 38-103.
    • (1996) Proc. CIGRE Conference
    • Ingelsson, B.1    Lindström, P.2    Karlsson, D.3    Runvik, G.4    Sjödin, J.5
  • 6
    • 13344262633 scopus 로고    scopus 로고
    • Design of an undervoltage load shedding scheme for the Hydro-Québec system
    • Toronto (Canada), July
    • D. Lefebvre, C. Moors, T. Van Cutsem, "Design of an undervoltage load shedding scheme for the Hydro-Québec system", Proc. IEEE PES General Meeting, Toronto (Canada), July 2003.
    • (2003) Proc. IEEE PES General Meeting
    • Lefebvre, D.1    Moors, C.2    Cutsem, T.V.3
  • 7
    • 27144518200 scopus 로고    scopus 로고
    • Undervoltage load shedding improving security as reasonable measure for extreme contingencies
    • San Francisco (USA)
    • S. Imai, "Undervoltage load shedding improving security as reasonable measure for extreme contingencies", Proc. IEEE PES General Meeting, San Francisco (USA), 2005.
    • (2005) Proc. IEEE PES General Meeting
    • Imai, S.1
  • 8
    • 36348941907 scopus 로고    scopus 로고
    • Undervoltage load shedding using distributed controllers
    • DOI 10.1109/TPWRS.2007.907354
    • B. Otomega, T. Van Cutsem, "Undervoltage load shedding using distributed controllers," IEEE Trans. Power Syst., vol. 22, no. 4, pp. 1898-1907, Nov. 2007. (Pubitemid 350141990)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.4 , pp. 1898-1907
    • Otomega, B.1    Van Cutsem, T.2
  • 12
    • 49249091611 scopus 로고    scopus 로고
    • Local identification of voltage emergency situations
    • Feb.
    • C. Vournas, T. Van Cutsem, "Local identification of voltage emergency situations," IEEE Trans. Power Syst., vol. 23, no.1, pp. 1239-1248, Feb. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.1 , pp. 1239-1248
    • Vournas, C.1    Van Cutsem, T.2
  • 13
    • 52349105607 scopus 로고    scopus 로고
    • Detecting with PMUs the onset of voltage instability caused by a large disturbance
    • Pittsburgh, PA, Jul.
    • M. Glavic, T. Van Cutsem, "Detecting with PMUs the onset of voltage instability caused by a large disturbance," in Proc. 2008 IEEE Power Eng. Soc. General Meeting, Pittsburgh, PA, Jul. 2008.
    • (2008) Proc. 2008 IEEE Power Eng. Soc. General Meeting
    • Glavic, M.1    Van Cutsem, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.