메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 582-591

Design strategies for load-shedding schemes against voltage collapse in the Hellenic System

Author keywords

Emergency control; Load shedding; Security assessment; System protection schemes; Voltage stability

Indexed keywords

ELECTRIC POWER SYSTEM PROTECTION; SECURITY SYSTEMS; VOLTAGE CONTROL;

EID: 43849093811     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2008.919242     Document Type: Article
Times cited : (65)

References (18)
  • 1
    • 43849088141 scopus 로고    scopus 로고
    • D. H. Karlsson, convener, System Protection Schemes in Power Networks, CIGRE Task Force 38.02.19.
    • D. H. Karlsson, , convener, System Protection Schemes in Power Networks, CIGRE Task Force 38.02.19.
  • 2
    • 0026850554 scopus 로고
    • Concepts of undervoltage load shedding for voltage stability
    • Apr
    • C. Taylor, "Concepts of undervoltage load shedding for voltage stability," IEEE Trans. Power Del., vol. 7, no. 2, pp. 480-488, Apr. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.2 , pp. 480-488
    • Taylor, C.1
  • 3
    • 0029305318 scopus 로고
    • An approach to corrective control ot voltage instability using simulation and sensitivity
    • May
    • T. Van Cutsem, "An approach to corrective control ot voltage instability using simulation and sensitivity," IEEE Trans. Power Syst., vol. 10, no. 2, pp. 616-622, May 1995.
    • (1995) IEEE Trans. Power Syst , vol.10 , Issue.2 , pp. 616-622
    • Van Cutsem, T.1
  • 6
    • 0003249007 scopus 로고    scopus 로고
    • Determination of optimal load shedding against voltage instability
    • Trondheim, Norway, Jul
    • C. Moors and T. Van Cutsem, "Determination of optimal load shedding against voltage instability," in Proc. 13th Power-System Computation Conf., Trondheim, Norway, Jul. 1999, pp. 993-1000.
    • (1999) Proc. 13th Power-System Computation Conf , pp. 993-1000
    • Moors, C.1    Van Cutsem, T.2
  • 7
    • 13844315887 scopus 로고    scopus 로고
    • Unified sensitivity analysis of unstable or low voltages caused by load increases or contingencies
    • Feb
    • F. Capitanescu and T. Van Cutsem, "Unified sensitivity analysis of unstable or low voltages caused by load increases or contingencies," IEEE Trans. Power Syst., vol. 20, no. 1, Feb. 2005.
    • (2005) IEEE Trans. Power Syst , vol.20 , Issue.1
    • Capitanescu, F.1    Van Cutsem, T.2
  • 9
    • 33747623060 scopus 로고    scopus 로고
    • Post mortem analysis and data validation in the wake of the 2004 Athens blackout
    • Aug
    • C. D. Vournass, V. C. Nikolaidis, and A. A. Tassoulis, "Post mortem analysis and data validation in the wake of the 2004 Athens blackout," IEEE Trans. Power. Sys., vol. 21, no. 3, pp. 1331-1339, Aug. 2006.
    • (2006) IEEE Trans. Power. Sys , vol.21 , Issue.3 , pp. 1331-1339
    • Vournass, C.D.1    Nikolaidis, V.C.2    Tassoulis, A.A.3
  • 11
    • 21244436499 scopus 로고    scopus 로고
    • Design aspects for wide-area monitoring and control systems
    • May
    • M. Zima, M. Larsson, P. Korba, C. Rehtanz, and G. Andersson, "Design aspects for wide-area monitoring and control systems," Proc. IEEE vol. 93, no. 5, pp. 980-996, May 2005.
    • (2005) Proc. IEEE , vol.93 , Issue.5 , pp. 980-996
    • Zima, M.1    Larsson, M.2    Korba, P.3    Rehtanz, C.4    Andersson, G.5
  • 13
    • 0031079074 scopus 로고    scopus 로고
    • Sensitivity of the loading margin to voltage collapse with respect to arbitrary parameters
    • Feb
    • S. Greene, I. Dobson, and F. L. Alvarado, "Sensitivity of the loading margin to voltage collapse with respect to arbitrary parameters," IEEE Trans. Power Syst., vol. 12, no. 1, pp. 262-272, Feb. 1997.
    • (1997) IEEE Trans. Power Syst , vol.12 , Issue.1 , pp. 262-272
    • Greene, S.1    Dobson, I.2    Alvarado, F.L.3
  • 15
    • 0034186782 scopus 로고    scopus 로고
    • A comprehensive approach for preventive and corrective control to mitigate voltage collapse
    • May
    • Z. Feng, V. Ajjarapu, and D. J. Maratukulam, "A comprehensive approach for preventive and corrective control to mitigate voltage collapse," IEEE Trans. Power Syst., vol. 15, no. 2, pp. 791-797, May 2000.
    • (2000) IEEE Trans. Power Syst , vol.15 , Issue.2 , pp. 791-797
    • Feng, Z.1    Ajjarapu, V.2    Maratukulam, D.J.3
  • 16
    • 31144469367 scopus 로고    scopus 로고
    • A corrective load shedding scheme to mitigate voltage collapse
    • Jan
    • F. M. Echavarren, E. Lobato, and L. Rouco, "A corrective load shedding scheme to mitigate voltage collapse," Int. J. Elect. Power Energy Syst., vol. 28, no. 1, pp. 58-64, Jan. 2006.
    • (2006) Int. J. Elect. Power Energy Syst , vol.28 , Issue.1 , pp. 58-64
    • Echavarren, F.M.1    Lobato, E.2    Rouco, L.3
  • 17
    • 84876753390 scopus 로고    scopus 로고
    • Experience gained by the application of a real-time voltage security assessment method at the Hellenic transmission system operator
    • Paris, France, Aug
    • G. Christoforidis, J. Kabouris, C. D. Vournas, and T. Van Cutsem, "Experience gained by the application of a real-time voltage security assessment method at the Hellenic transmission system operator," in Paper C2-206, CIGRE, Paris, France, Aug. 2006.
    • (2006) Paper C2-206, CIGRE
    • Christoforidis, G.1    Kabouris, J.2    Vournas, C.D.3    Van Cutsem, T.4
  • 18
    • 50849132877 scopus 로고    scopus 로고
    • Interarea oscillations and tie-line transients in the hellenic interconnected system
    • Lausanne, Switzerland, Jul
    • B. M. Nomikos, M. A. Kotlida, and C. D. Vournas, "Interarea oscillations and tie-line transients in the hellenic interconnected system," in Proc. IEEE/Power Eng. Soc. Power Tech Conf., Lausanne, Switzerland, Jul. 2007.
    • (2007) Proc. IEEE/Power Eng. Soc. Power Tech Conf
    • Nomikos, B.M.1    Kotlida, M.A.2    Vournas, C.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.