메뉴 건너뛰기




Volumn 8, Issue 1, 2010, Pages 1-6

Imaging to guide transcatheter aortic valve implantation

Author keywords

Aortic valve stenosis; Echocardiography; Multi slice computed tomography; Transcatheter aortic valve implantation

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; CORONARY ARTERY DISEASE; ECHOCARDIOGRAPHY; FLUOROSCOPY; FOLLOW UP; HUMAN; MULTIDETECTOR COMPUTED TOMOGRAPHY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT SELECTION; REVIEW; SURGICAL APPROACH; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 74849138470     PISSN: 13490222     EISSN: 1880344X     Source Type: Journal    
DOI: 10.1007/s12574-010-0033-1     Document Type: Review
Times cited : (8)

References (24)
  • 1
    • 0038267070 scopus 로고    scopus 로고
    • A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease
    • Iung B, Baron G, Butchart EG, Delahaye F, Gohlke-Bärwolf C, Levang OW, et al. A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. Eur Heart J. 2003; 24: 1231-43.
    • (2003) Eur Heart J , vol.24 , pp. 1231-1243
    • Iung, B.1    Baron, G.2    Butchart, E.G.3    Delahaye, F.4    Gohlke-Bärwolf, C.5    Levang, O.W.6
  • 2
    • 28544435658 scopus 로고    scopus 로고
    • Decision-making in elderly patients with severe aortic stenosis: Why are so many denied surgery?
    • Iung B, Cachier A, Baron G, Messika-Zeitoun D, Delahaye F, Tornos P, et al. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J. 2005; 26: 2714-20.
    • (2005) Eur Heart J , vol.26 , pp. 2714-2720
    • Iung, B.1    Cachier, A.2    Baron, G.3    Messika-Zeitoun, D.4    Delahaye, F.5    Tornos, P.6
  • 3
    • 33747116680 scopus 로고    scopus 로고
    • ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease)
    • Bonow RO, Carabello BA, Kanu C, de Leon AC Jr, Faxon DP, Freed MD, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation. 2006; 114: e84-231.
    • (2006) Circulation , vol.114
    • Bonow, R.O.1    Carabello, B.A.2    Kanu, C.3    de Leon Jr., A.C.4    Faxon, D.P.5    Freed, M.D.6
  • 4
    • 33847134400 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology
    • Vahanian A, Baumgartner H, Bax J, Butchart E, Dion R, Filippatos G, et al. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology. Eur Heart J. 2007; 28: 230-68.
    • (2007) Eur Heart J , vol.28 , pp. 230-268
    • Vahanian, A.1    Baumgartner, H.2    Bax, J.3    Butchart, E.4    Dion, R.5    Filippatos, G.6
  • 5
    • 60849121992 scopus 로고    scopus 로고
    • Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve Revalving system
    • Grube E, Buellesfeld L, Mueller R, Sauren B, Zickmann B, Nair D, et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ Cardiovasc Interv. 2008; 1: 167-75.
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 167-175
    • Grube, E.1    Buellesfeld, L.2    Mueller, R.3    Sauren, B.4    Zickmann, B.5    Nair, D.6
  • 6
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow-up from the initial feasibility studies: The French experience
    • Cribier A, Eltchaninoff H, Tron C, Bauer F, Agatiello C, Nercolini D, et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol. 2006; 47: 1214-23.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3    Bauer, F.4    Agatiello, C.5    Nercolini, D.6
  • 7
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • Himbert D, Descoutures F, Al-Attar N, Iung B, Ducrocq G, Détaint D, et al. Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis. J Am Coll Cardiol. 2009; 54: 303-11.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al-Attar, N.3    Iung, B.4    Ducrocq, G.5    Détaint, D.6
  • 8
    • 54549085618 scopus 로고    scopus 로고
    • Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis
    • Rodés-Cabau J, Dumont E, De LaRochellière R, Doyle D, Lemieux J, Bergeron S, et al. Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis. Am J Cardiol. 2008; 102: 1240-6.
    • (2008) Am J Cardiol , vol.102 , pp. 1240-1246
    • Rodés-Cabau, J.1    Dumont, E.2    de Larochellière, R.3    Doyle, D.4    Lemieux, J.5    Bergeron, S.6
  • 9
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A, Cribier AG. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol. 2009; 53: 1829-36.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 10
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • Webb JG, Altwegg L, Boone RH, Cheung A, Ye J, Lichtenstein S, et al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation. 2009; 119: 3009-16.
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3    Cheung, A.4    Ye, J.5    Lichtenstein, S.6    Lee, M.7
  • 11
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, et al. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008; 4: 242-9.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    den Heijer, P.4    Linke, A.5    Luha, O.6
  • 12
    • 38349136447 scopus 로고    scopus 로고
    • Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults
    • Zegdi R, Ciobotaru V, Noghin M, Sleilaty G, Lafont A, Latrémouille C, et al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. J Am Coll Cardiol. 2008; 51: 579-84.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 579-584
    • Zegdi, R.1    Ciobotaru, V.2    Noghin, M.3    Sleilaty, G.4    Lafont, A.5    Latrémouille, C.6
  • 13
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • Vahanian A, Alfieri O, Al-Attar N, Antunes M, Bax J, Cormier B, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J. 2008; 29: 1463-70.
    • (2008) Eur Heart J , vol.29 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.2    Al-Attar, N.3    Antunes, M.4    Bax, J.5    Cormier, B.6
  • 14
    • 70350054784 scopus 로고    scopus 로고
    • Successful deployment of a transcatheter aortic valve in bicuspid aortic stenosis: Role of imaging with multislice computed tomography
    • Delgado V, Tops LF, Schuijf JD, van der Kley F, van de Veire NR, Schalij MJ, et al. Successful deployment of a transcatheter aortic valve in bicuspid aortic stenosis: role of imaging with multislice computed tomography. Circ Cardiovasc Imaging. 2009; 2: e12-3.
    • (2009) Circ Cardiovasc Imaging , vol.2
    • Delgado, V.1    Tops, L.F.2    Schuijf, J.D.3    van der Kley, F.4    van de Veire, N.R.5    Schalij, M.J.6
  • 16
    • 0242298641 scopus 로고    scopus 로고
    • Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis: Comparison with echocardiography
    • Caruthers SD, Lin SJ, Brown P, Watkins MP, Williams TA, Lehr KA, et al. Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis: comparison with echocardiography. Circulation. 2003; 108: 2236-43.
    • (2003) Circulation , vol.108 , pp. 2236-2243
    • Caruthers, S.D.1    Lin, S.J.2    Brown, P.3    Watkins, M.P.4    Williams, T.A.5    Lehr, K.A.6
  • 17
    • 34548080997 scopus 로고    scopus 로고
    • Aortic valve area assessment: Multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography
    • Pouleur AC, le Polain de Waroux JB, Pasquet A, Vanoverschelde JL, Gerber BL, et al. Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography. Radiology. 2007; 244: 745-54.
    • (2007) Radiology , vol.244 , pp. 745-754
    • Pouleur, A.C.1    Le Polain de Waroux, J.B.2    Pasquet, A.3    Vanoverschelde, J.L.4    Gerber, B.L.5
  • 18
    • 70350437284 scopus 로고    scopus 로고
    • Aortic root measurement by cardiovascular magnetic resonance: Specification of planes and lines of measurement and corresponding normal values
    • Burman ED, Keegan J, Kilner PJ. Aortic root measurement by cardiovascular magnetic resonance: specification of planes and lines of measurement and corresponding normal values. Circ Cardiovasc Imaging. 2008; 1: 104-13.
    • (2008) Circ Cardiovasc Imaging , vol.1 , pp. 104-113
    • Burman, E.D.1    Keegan, J.2    Kilner, P.J.3
  • 21
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, et al. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging. 2008; 1: 321-30.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 321-330
    • Tops, L.F.1    Wood, D.A.2    Delgado, V.3    Schuijf, J.D.4    Mayo, J.R.5    Pasupati, S.6
  • 23
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Wenaweser P, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol. 2007; 50: 69-76.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3    Gerckens, U.4    Linke, A.5    Wenaweser, P.6
  • 24
    • 34547919242 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
    • Webb JG, Pasupati S, Humphries K, Thompson C, Altwegg L, Moss R, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007; 116: 755-63.
    • (2007) Circulation , vol.116 , pp. 755-763
    • Webb, J.G.1    Pasupati, S.2    Humphries, K.3    Thompson, C.4    Altwegg, L.5    Moss, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.