메뉴 건너뛰기




Volumn 10, Issue 1, 2010, Pages 32-35

Up to twenty-five-year survival after aortic valve replacement with size 19 mm valves

Author keywords

Mid term survival; Patient prosthesis mismatch; Small aortic prosthesis

Indexed keywords

ADULT; AGE DISTRIBUTION; AGED; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTICLE; BODY SURFACE; CARDIAC PATIENT; CONTROLLED STUDY; DIABETES MELLITUS; FEMALE; FOLLOW UP; HEART DEATH; HEART EJECTION FRACTION; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SEX DIFFERENCE; SURVIVAL RATE; SURVIVAL TIME;

EID: 74849123527     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2009.209197     Document Type: Article
Times cited : (7)

References (15)
  • 2
    • 58649110827 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthesic aortic valve replacement
    • Moon MR, Lawton JS, Moazami N, Munfakh NA, Pasque MK, Damiano RJ. Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthesic aortic valve replacement. J Thorac Cardiovasc Surg 2009;137:278-283.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 278-283
    • Moon, M.R.1    Lawton, J.S.2    Moazami, N.3    Munfakh, N.A.4    Pasque, M.K.5    Damiano, R.J.6
  • 5
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    • Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000;36:1131-1141.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.G.2
  • 7
    • 21044431634 scopus 로고    scopus 로고
    • Impact of prosthesis-patient size on functional recovery after aortic valve replacement
    • Koch CG, Khandwala F, Estafanous FG, Loop FD, Blackstone EH. Impact of prosthesis-patient size on functional recovery after aortic valve replacement. Circulation 2005;111:3221-3229.
    • (2005) Circulation , vol.111 , pp. 3221-3229
    • Koch, C.G.1    Khandwala, F.2    Estafanous, F.G.3    Loop, F.D.4    Blackstone, E.H.5
  • 8
    • 0032806720 scopus 로고    scopus 로고
    • Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise. Implications for the surgical management of patients with small aortic roots
    • Gonzalez-Juanatey JR, Fernandez MV, Sampedro FG, Garcia-Acuña JM, Garcia-Bengoechea JB, Cendon AA, de la Peña MG. Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise. Implications for the surgical management of patients with small aortic roots. Heart 1999;82:149-155.
    • (1999) Heart , vol.82 , pp. 149-155
    • Gonzalez-Juanatey, J.R.1    Fernandez, M.V.2    Sampedro, F.G.3    Garcia-Acuña, J.M.4    Garcia-Bengoechea, J.B.5    Cendon, A.A.6    de la Peña, M.G.7
  • 9
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient-mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient-mismatch. Circulation 1978;58:20-24.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 12
    • 0034619384 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch affects survival after aortic valve replacement
    • III:III5-III9
    • Rao V, Jamieson WRE, Ivanov J, Armtrong S, David TE. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 2000;102(Suppl III):III5-III9.
    • (2000) Circulation , vol.102 , Issue.SUPPL.
    • Rao, V.1    Jamieson, W.R.E.2    Ivanov, J.3    Armtrong, S.4    David, T.E.5
  • 13
    • 0035002158 scopus 로고    scopus 로고
    • Carrier M, Pelllerin M, Perrault LP, Hebert Y, Page P, Cartier R, Dyrda I, Pelletier LC. Experience with the 19 mm Carpentier-Edwards pericardial bioprosthesis in the elderly. Ann Thorac Surg 2001;71:S249-S252.
    • Carrier M, Pelllerin M, Perrault LP, Hebert Y, Page P, Cartier R, Dyrda I, Pelletier LC. Experience with the 19 mm Carpentier-Edwards pericardial bioprosthesis in the elderly. Ann Thorac Surg 2001;71:S249-S252.
  • 14
    • 0028914551 scopus 로고
    • Up to thirty-year survival after aortic valve replacement in the small aortic root
    • He GW, Grunkemeier GL, Gately HL, Furnary AP, Starr A. Up to thirty-year survival after aortic valve replacement in the small aortic root. Ann Thorac Surg 1995;59:1056-1062.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1056-1062
    • He, G.W.1    Grunkemeier, G.L.2    Gately, H.L.3    Furnary, A.P.4    Starr, A.5
  • 15
    • 33646205280 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with pre-existing left ventricular dysfunction: Effect on survival, freedom from heart failure and left ventricular mass regression
    • Ruel M, Al-Faleh H, Kulik A, Chan KL, Mesana TG, Burwash IG. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with pre-existing left ventricular dysfunction: effect on survival, freedom from heart failure and left ventricular mass regression. J Thorac Cardiovasc Surg 2006;131:1036-1044.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 1036-1044
    • Ruel, M.1    Al-Faleh, H.2    Kulik, A.3    Chan, K.L.4    Mesana, T.G.5    Burwash, I.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.