메뉴 건너뛰기




Volumn 41, Issue 2, 2010, Pages 179-183

Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: Are all screws created equal?

Author keywords

Holding strength; Osteoporosis; Scaphoid fractures; Variable pitch screw

Indexed keywords

POLYURETHAN FOAM;

EID: 74849109664     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2009.08.015     Document Type: Article
Times cited : (82)

References (19)
  • 1
    • 10044279312 scopus 로고    scopus 로고
    • Compression forces generated by mini bone screws-a comparative study done on bone model
    • Adla D.N., Kistis C., and Miles A.W. Compression forces generated by mini bone screws-a comparative study done on bone model. Injury 36 1 (2005) 65-70
    • (2005) Injury , vol.36 , Issue.1 , pp. 65-70
    • Adla, D.N.1    Kistis, C.2    Miles, A.W.3
  • 2
    • 0030345576 scopus 로고    scopus 로고
    • Cancellous bone screw thread design and holding power
    • Asnis S.E., Ernberg J.J., Bostrom M.P.G., et al. Cancellous bone screw thread design and holding power. J Orthop Trauma 10 (1996) 462-469
    • (1996) J Orthop Trauma , vol.10 , pp. 462-469
    • Asnis, S.E.1    Ernberg, J.J.2    Bostrom, M.P.G.3
  • 3
    • 33646982724 scopus 로고    scopus 로고
    • Standard specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments
    • ASTM F 1839-01, American Society for Testing and Materials;
    • ASTM F 1839-01. Standard specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments. American Society for Testing and Materials; 2002.
    • (2002)
  • 4
    • 0034279671 scopus 로고    scopus 로고
    • Scarf osteotomy for hallux valgus correction. Local anatomy, surgical technique, and combination with other forefoot procedures
    • Barouk L.S. Scarf osteotomy for hallux valgus correction. Local anatomy, surgical technique, and combination with other forefoot procedures. Foot Ankle Clin 5 (2000) 525-558
    • (2000) Foot Ankle Clin , vol.5 , pp. 525-558
    • Barouk, L.S.1
  • 5
    • 0030221045 scopus 로고    scopus 로고
    • Factors affecting the pullout strengths of cancellous bone screws
    • Chapman J.R., Harrington R.M., Lee K.M., et al. Factors affecting the pullout strengths of cancellous bone screws. J Biomech Eng 118 (1996) 391-398
    • (1996) J Biomech Eng , vol.118 , pp. 391-398
    • Chapman, J.R.1    Harrington, R.M.2    Lee, K.M.3
  • 7
    • 3342928907 scopus 로고    scopus 로고
    • Biomechanical study of pedicle screw fixation in severely osteoporotic bone
    • Cook S.D., Salkeld S.L., Stanley T., et al. Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4 (2004) 402-408
    • (2004) Spine J , vol.4 , pp. 402-408
    • Cook, S.D.1    Salkeld, S.L.2    Stanley, T.3
  • 9
    • 47549112283 scopus 로고    scopus 로고
    • Clinical and radiological outcome of cast immobilisation versus surgical treatment of acute scaphoid fractures at a mean follow-up of 93 months
    • Dias J.J., Dhukaram V., Abhinav A., et al. Clinical and radiological outcome of cast immobilisation versus surgical treatment of acute scaphoid fractures at a mean follow-up of 93 months. J Bone Joint Surg Br 90 (2008) 899-905
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 899-905
    • Dias, J.J.1    Dhukaram, V.2    Abhinav, A.3
  • 10
    • 34249932895 scopus 로고    scopus 로고
    • Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model
    • Hausmann J.T., Mayr W., Unger E., et al. Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model. Injury 38 (2007) 763-768
    • (2007) Injury , vol.38 , pp. 763-768
    • Hausmann, J.T.1    Mayr, W.2    Unger, E.3
  • 11
    • 0027349113 scopus 로고
    • Extraction strength of cannulated cancellous bone screws
    • Hearn T.C., Schatzker J., and Wolfson N. Extraction strength of cannulated cancellous bone screws. J Orthop Trauma 7 (1993) 138-141
    • (1993) J Orthop Trauma , Issue.7 , pp. 138-141
    • Hearn, T.C.1    Schatzker, J.2    Wolfson, N.3
  • 12
    • 67650588165 scopus 로고    scopus 로고
    • Percutaneous screw fixation without bone graft for cystic-type scaphoid fractures
    • Ikeda K., Osamura N., and Tomita K. Percutaneous screw fixation without bone graft for cystic-type scaphoid fractures. J Trauma 65 (2008) 1453-1458
    • (2008) J Trauma , vol.65 , pp. 1453-1458
    • Ikeda, K.1    Osamura, N.2    Tomita, K.3
  • 13
    • 0026440671 scopus 로고
    • Holding power and reinforcement of cancellous screws in human bone
    • Kleeman B.C., Takeuchi T., Gerhart T.N., and Hayes W.C. Holding power and reinforcement of cancellous screws in human bone. Clin Orthop Rel Res 284 (1992) 260-266
    • (1992) Clin Orthop Rel Res , vol.284 , pp. 260-266
    • Kleeman, B.C.1    Takeuchi, T.2    Gerhart, T.N.3    Hayes, W.C.4
  • 14
    • 0025081586 scopus 로고
    • Biomechanical and histological evaluation of the Herbert screw
    • Lange R.H., Vanderby R.J., Engber W.D., et al. Biomechanical and histological evaluation of the Herbert screw. J Orthop Trauma 4 (1990) 275-282
    • (1990) J Orthop Trauma , Issue.4 , pp. 275-282
    • Lange, R.H.1    Vanderby, R.J.2    Engber, W.D.3
  • 15
    • 0035857351 scopus 로고    scopus 로고
    • diagnosis and therapy
    • NIH Consensus developmental panel on osteoporosis prevention
    • NIH Consensus developmental panel on osteoporosis prevention, diagnosis and therapy. J Am Med Assoc 2001;285:785-95.
    • (2001) J Am Med Assoc , vol.285 , pp. 785-795
  • 16
    • 18844372749 scopus 로고    scopus 로고
    • Herbert screw fixation of capitellar fractures
    • Sano S., Rokkaku T., Saito S., et al. Herbert screw fixation of capitellar fractures. J Shoulder Elbow Surg 14 (2005) 307-311
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 307-311
    • Sano, S.1    Rokkaku, T.2    Saito, S.3
  • 17
    • 26944498694 scopus 로고    scopus 로고
    • Mechanical behaviour of screws in normal and osteoporotic bone
    • Seebeck J., Goldhahn J., Morlock M.M., and Schneider E. Mechanical behaviour of screws in normal and osteoporotic bone. Osteopor Int 16 (2005) 107-111
    • (2005) Osteopor Int , vol.16 , pp. 107-111
    • Seebeck, J.1    Goldhahn, J.2    Morlock, M.M.3    Schneider, E.4
  • 18
    • 0030873579 scopus 로고    scopus 로고
    • Pullout strengths of cannulated and noncannulated cancellous bone screws
    • Thompson J.D., Benjamin J.B., and Sczivek J.A. Pullout strengths of cannulated and noncannulated cancellous bone screws. Clin Orthop Rel Res 341 (1997) 241-324
    • (1997) Clin Orthop Rel Res , vol.341 , pp. 241-324
    • Thompson, J.D.1    Benjamin, J.B.2    Sczivek, J.A.3
  • 19
    • 0031980880 scopus 로고    scopus 로고
    • Biomechanical assessment of compression screws
    • Wheeler D.L., and McLoughlin S.W. Biomechanical assessment of compression screws. Clin Orthop Rel Res 350 (1998) 237-245
    • (1998) Clin Orthop Rel Res , vol.350 , pp. 237-245
    • Wheeler, D.L.1    McLoughlin, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.