메뉴 건너뛰기




Volumn 36, Issue 2, 2010, Pages 325-335

Opening of the Blood-Brain Barrier by Low-Frequency (28-kHz) Ultrasound: A Novel Pinhole-Assisted Mechanical Scanning Device

Author keywords

Blood brain barrier disruption; Low frequency ultrasound; Pinhole assisted mechanical scanning

Indexed keywords

BLOOD-BRAIN BARRIER; BRAIN LESIONS; CEREBRAL TUMORS; EXPERIMENTAL ANIMALS; FOCUSED ULTRASOUND; HIGH FREQUENCY HF; IMAGE GUIDANCES; LOW FREQUENCY; LOW-FREQUENCY ULTRASOUND; MECHANICAL SCANNING; MECHANICAL SCANNING DEVICES; MICROBUBBLES; WIDE AREA;

EID: 74849090327     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2009.10.004     Document Type: Article
Times cited : (30)

References (39)
  • 1
    • 0030099527 scopus 로고    scopus 로고
    • Transporting therapeutics across the blood-brain barrier
    • Abbott N.J., and Romero I.A. Transporting therapeutics across the blood-brain barrier. Mol Med Today 2 (1996) 106-113
    • (1996) Mol Med Today , vol.2 , pp. 106-113
    • Abbott, N.J.1    Romero, I.A.2
  • 3
    • 0031816671 scopus 로고    scopus 로고
    • Ultrasound. Nonthermal issues: Cavitation - Its nature, detection and measurement
    • Barnett S.B. Ultrasound. Nonthermal issues: Cavitation - Its nature, detection and measurement. Ultrasound Med Biol 24 (1998) 11-21
    • (1998) Ultrasound Med Biol , vol.24 , pp. 11-21
    • Barnett, S.B.1
  • 4
    • 69249226362 scopus 로고    scopus 로고
    • Rat brain tumor models in experimental neuro-oncology: The C6, 9L, T9, RG2, F98, BT4C, RT-2 and CNS-1 gliomas
    • Barth R.F., and Kaur B. Rat brain tumor models in experimental neuro-oncology: The C6, 9L, T9, RG2, F98, BT4C, RT-2 and CNS-1 gliomas. J Neurooncol (2009)
    • (2009) J Neurooncol
    • Barth, R.F.1    Kaur, B.2
  • 5
    • 0035834196 scopus 로고    scopus 로고
    • In vitro study of low-frequency ultrasound-enhanced transdermal transport of fentanyl and caffeine across human and hairless rat skin
    • Boucaud A., Machet L., Arbeille B., Machet M.C., Sournac M., Mavon A., Patat F., and Vaillant L. In vitro study of low-frequency ultrasound-enhanced transdermal transport of fentanyl and caffeine across human and hairless rat skin. Int J Pharm 228 (2001) 69-77
    • (2001) Int J Pharm , vol.228 , pp. 69-77
    • Boucaud, A.1    Machet, L.2    Arbeille, B.3    Machet, M.C.4    Sournac, M.5    Mavon, A.6    Patat, F.7    Vaillant, L.8
  • 6
    • 33845675648 scopus 로고    scopus 로고
    • Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    • Choi J.J., Pernot M., Small S.A., and Konofagou E.E. Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Ultrasound Med Biol 33 (2007) 95-104
    • (2007) Ultrasound Med Biol , vol.33 , pp. 95-104
    • Choi, J.J.1    Pernot, M.2    Small, S.A.3    Konofagou, E.E.4
  • 7
    • 0029919121 scopus 로고    scopus 로고
    • Acoustically enhanced bubble growth at low frequencies and its implications for human diver and marine mammal safety
    • Crum L.A., and Mao Y. Acoustically enhanced bubble growth at low frequencies and its implications for human diver and marine mammal safety. J Acoust Soc Am 99 (1996) 2898-2907
    • (1996) J Acoust Soc Am , vol.99 , pp. 2898-2907
    • Crum, L.A.1    Mao, Y.2
  • 8
    • 0036858483 scopus 로고    scopus 로고
    • Therapeutic ultrasound in ischemic stroke treatment: Experimental evidence
    • Daffertshofer M., and Fatar M. Therapeutic ultrasound in ischemic stroke treatment: Experimental evidence. Eur J Ultrasound 16 (2002) 121-130
    • (2002) Eur J Ultrasound , vol.16 , pp. 121-130
    • Daffertshofer, M.1    Fatar, M.2
  • 9
    • 22044441701 scopus 로고    scopus 로고
    • Transcranial low-frequency ultrasound-mediated thrombolysis in brain ischemia: Increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: Results of a phase II clinical trial
    • Daffertshofer M., Gass A., Ringleb P., Sitzer M., Sliwka U., Els T., Sedlaczek O., Koroshetz W.J., and Hennerici M.G. Transcranial low-frequency ultrasound-mediated thrombolysis in brain ischemia: Increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: Results of a phase II clinical trial. Stroke 36 (2005) 1441-1446
    • (2005) Stroke , vol.36 , pp. 1441-1446
    • Daffertshofer, M.1    Gass, A.2    Ringleb, P.3    Sitzer, M.4    Sliwka, U.5    Els, T.6    Sedlaczek, O.7    Koroshetz, W.J.8    Hennerici, M.G.9
  • 10
    • 0033659367 scopus 로고    scopus 로고
    • Ultrasound-enhanced thrombolysis at 20 kHz with air-filled and perfluorocarbon-filled contrast bispheres
    • Dhond M.R., Nguyen T.T., Dolan C., Pulido G., and Bommer W.J. Ultrasound-enhanced thrombolysis at 20 kHz with air-filled and perfluorocarbon-filled contrast bispheres. J Am Soc Echocardiogr 13 (2000) 1025-1029
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 1025-1029
    • Dhond, M.R.1    Nguyen, T.T.2    Dolan, C.3    Pulido, G.4    Bommer, W.J.5
  • 12
    • 0025265018 scopus 로고
    • The concentric-ring array for ultrasound hyperthermia: Combined mechanical and electrical scanning
    • Ebbini M.S., and Cain C.A. The concentric-ring array for ultrasound hyperthermia: Combined mechanical and electrical scanning. Int J Hyperthermia 6 (1990) 401-419
    • (1990) Int J Hyperthermia , vol.6 , pp. 401-419
    • Ebbini, M.S.1    Cain, C.A.2
  • 14
    • 0014238869 scopus 로고
    • Laser schlieren optical system for analyzing ultrasonic fields
    • Harding D.C., and Baker D.W. Laser schlieren optical system for analyzing ultrasonic fields. Biomed Sci Instrum 4 (1968) 223-230
    • (1968) Biomed Sci Instrum , vol.4 , pp. 223-230
    • Harding, D.C.1    Baker, D.W.2
  • 15
    • 4644312297 scopus 로고    scopus 로고
    • Five-hundred-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
    • Hynynen K., Clement G.T., McDannold N., Vykhodtseva N., King R., White P.J., Vitek S., and Jolesz F.A. Five-hundred-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. Magn Reson Med 52 (2004) 100-107
    • (2004) Magn Reson Med , vol.52 , pp. 100-107
    • Hynynen, K.1    Clement, G.T.2    McDannold, N.3    Vykhodtseva, N.4    King, R.5    White, P.J.6    Vitek, S.7    Jolesz, F.A.8
  • 16
    • 33746242230 scopus 로고    scopus 로고
    • Preclinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-A primate study
    • Hynynen K., McDannold N., Clement G., Jolesz F.A., Zadicario E., Killiany R., Moore T., and Rosen D. Preclinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-A primate study. Eur J Radiol 59 (2006) 149-156
    • (2006) Eur J Radiol , vol.59 , pp. 149-156
    • Hynynen, K.1    McDannold, N.2    Clement, G.3    Jolesz, F.A.4    Zadicario, E.5    Killiany, R.6    Moore, T.7    Rosen, D.8
  • 17
    • 10044278240 scopus 로고    scopus 로고
    • Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications
    • Hynynen K., McDannold N., Sheikov N.A., Jolesz F.A., and Vykhodtseva N. Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications. Neuroimage 24 (2005) 12-20
    • (2005) Neuroimage , vol.24 , pp. 12-20
    • Hynynen, K.1    McDannold, N.2    Sheikov, N.A.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 18
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K., McDannold N., Vykhodtseva N., and Jolesz F.A. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 220 (2001) 640-646
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 20
    • 33748483260 scopus 로고    scopus 로고
    • Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery
    • Hynynen K., McDannold N., Vykhodtseva N., Raymond S., Weissleder R., Jolesz F.A., and Sheikov N. Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery. J Neurosurg 105 (2006) 445-454
    • (2006) J Neurosurg , vol.105 , pp. 445-454
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Raymond, S.4    Weissleder, R.5    Jolesz, F.A.6    Sheikov, N.7
  • 21
    • 30544447180 scopus 로고    scopus 로고
    • Targeted delivery of antibodies through the blood-brain barrier by MRI-guided focused ultrasound
    • Kinoshita M., McDannold N., Jolesz F.A., and Hynynen K. Targeted delivery of antibodies through the blood-brain barrier by MRI-guided focused ultrasound. Biochem Biophys Res Commun 340 (2006) 1085-1090
    • (2006) Biochem Biophys Res Commun , vol.340 , pp. 1085-1090
    • Kinoshita, M.1    McDannold, N.2    Jolesz, F.A.3    Hynynen, K.4
  • 22
    • 33746362477 scopus 로고    scopus 로고
    • A simple Schlieren system for visualizing a sound field of pulsed ultrasound
    • Kudo N., Ouchi H., Yamamoto K., and Sekimizu H. A simple Schlieren system for visualizing a sound field of pulsed ultrasound. J Phys Conf Ser 1 (2004) 146-149
    • (2004) J Phys Conf Ser , vol.1 , pp. 146-149
    • Kudo, N.1    Ouchi, H.2    Yamamoto, K.3    Sekimizu, H.4
  • 23
    • 40949159717 scopus 로고    scopus 로고
    • Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging
    • Liu H.L., Wai Y.Y., Chen W.S., Chen J.C., Hsu P.H., Wu X.Y., Huang W.C., Yen T.C., and Wang J.J. Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging. Ultrasound Med Biol 34 (2008) 598-606
    • (2008) Ultrasound Med Biol , vol.34 , pp. 598-606
    • Liu, H.L.1    Wai, Y.Y.2    Chen, W.S.3    Chen, J.C.4    Hsu, P.H.5    Wu, X.Y.6    Huang, W.C.7    Yen, T.C.8    Wang, J.J.9
  • 24
    • 42949140276 scopus 로고    scopus 로고
    • Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index
    • McDannold N., Vykhodtseva N., and Hynynen K. Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index. Ultrasound Med Biol 34 (2008) 834-840
    • (2008) Ultrasound Med Biol , vol.34 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 25
    • 27744441243 scopus 로고    scopus 로고
    • MRI-guided targeted blood-brain barrier disruption with focused ultrasound: Histological findings in rabbits
    • McDannold N., Vykhodtseva N., Raymond S., Jolesz F.A., and Hynynen K. MRI-guided targeted blood-brain barrier disruption with focused ultrasound: Histological findings in rabbits. Ultrasound Med Biol 31 (2005) 1527-1537
    • (2005) Ultrasound Med Biol , vol.31 , pp. 1527-1537
    • McDannold, N.1    Vykhodtseva, N.2    Raymond, S.3    Jolesz, F.A.4    Hynynen, K.5
  • 26
    • 33751312312 scopus 로고    scopus 로고
    • Ultrasound, microbubbles and the blood-brain barrier
    • Meairs S., and Alonso A. Ultrasound, microbubbles and the blood-brain barrier. Prog Biophys Mol Biol 93 (2007) 354-362
    • (2007) Prog Biophys Mol Biol , vol.93 , pp. 354-362
    • Meairs, S.1    Alonso, A.2
  • 27
    • 34249108934 scopus 로고    scopus 로고
    • Three-point support mechanical steering system for high intensity focused ultrasound
    • Meaney P.M., Raynolds T., Potwin L., and Paulsen K.D. Three-point support mechanical steering system for high intensity focused ultrasound. Phys Med Biol 52 (2007) 3045-3056
    • (2007) Phys Med Biol , vol.52 , pp. 3045-3056
    • Meaney, P.M.1    Raynolds, T.2    Potwin, L.3    Paulsen, K.D.4
  • 29
    • 0037001995 scopus 로고    scopus 로고
    • Neurotrophins, neuroprotection and the blood-brain barrier
    • Pardridge W.M. Neurotrophins, neuroprotection and the blood-brain barrier. Curr Opin Investig Drugs 3 (2002) 1753-1757
    • (2002) Curr Opin Investig Drugs , vol.3 , pp. 1753-1757
    • Pardridge, W.M.1
  • 30
    • 0036144376 scopus 로고    scopus 로고
    • Targeting neurotherapeutic agents through the blood-brain barrier
    • Pardridge W.M. Targeting neurotherapeutic agents through the blood-brain barrier. Arch Neurol 59 (2002) 35-40
    • (2002) Arch Neurol , vol.59 , pp. 35-40
    • Pardridge, W.M.1
  • 31
    • 0029807006 scopus 로고    scopus 로고
    • Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles
    • Porter T.R., LeVeen R.F., Fox R., Kricsfeld A., and Xie F. Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles. Am Heart J 132 (1996) 964-968
    • (1996) Am Heart J , vol.132 , pp. 964-968
    • Porter, T.R.1    LeVeen, R.F.2    Fox, R.3    Kricsfeld, A.4    Xie, F.5
  • 32
    • 0015386106 scopus 로고
    • Testing of a hypothesis for osmotic opening of the blood-brain barrier
    • Rapoport S.I., Hori M., and Klatzo I. Testing of a hypothesis for osmotic opening of the blood-brain barrier. Am J Physiol 223 (1972) 323-331
    • (1972) Am J Physiol , vol.223 , pp. 323-331
    • Rapoport, S.I.1    Hori, M.2    Klatzo, I.3
  • 35
    • 0034674020 scopus 로고    scopus 로고
    • Effect of 40-kHz ultrasound on acute thrombotic ischemia in a rabbit femoral artery thrombosis model: Enhancement of thrombolysis and improvement in capillary muscle perfusion
    • Suchkova V.N., Baggs R.B., and Francis C.W. Effect of 40-kHz ultrasound on acute thrombotic ischemia in a rabbit femoral artery thrombosis model: Enhancement of thrombolysis and improvement in capillary muscle perfusion. Circulation 101 (2000) 2296-2301
    • (2000) Circulation , vol.101 , pp. 2296-2301
    • Suchkova, V.N.1    Baggs, R.B.2    Francis, C.W.3
  • 36
    • 0345413329 scopus 로고    scopus 로고
    • Interactions of inertial cavitation bubbles with stratum corneum lipid bilayers during low-frequency sonophoresis
    • Tezel A., and Mitragotri S. Interactions of inertial cavitation bubbles with stratum corneum lipid bilayers during low-frequency sonophoresis. Biophys J 85 (2003) 3502-3512
    • (2003) Biophys J , vol.85 , pp. 3502-3512
    • Tezel, A.1    Mitragotri, S.2
  • 37
    • 34547121440 scopus 로고    scopus 로고
    • Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound
    • Treat L.H., McDannold N., Vykhodtseva N., Zhang Y., Tam K., and Hynynen K. Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound. Int J Cancer 121 (2007) 901-907
    • (2007) Int J Cancer , vol.121 , pp. 901-907
    • Treat, L.H.1    McDannold, N.2    Vykhodtseva, N.3    Zhang, Y.4    Tam, K.5    Hynynen, K.6
  • 38
    • 44149102122 scopus 로고    scopus 로고
    • Ultrasound, cavitation bubbles and their interaction with cells
    • Wu J., and Nyborg W.L. Ultrasound, cavitation bubbles and their interaction with cells. Adv Drug Deliv Rev 60 (2008) 1103-1116
    • (2008) Adv Drug Deliv Rev , vol.60 , pp. 1103-1116
    • Wu, J.1    Nyborg, W.L.2
  • 39
    • 44249098561 scopus 로고    scopus 로고
    • Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    • Yang F.Y., Fu W.M., Chen W.S., Yeh W.L., and Lin W.L. Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption. Ultrason Sonochem 15 (2008) 636-643
    • (2008) Ultrason Sonochem , vol.15 , pp. 636-643
    • Yang, F.Y.1    Fu, W.M.2    Chen, W.S.3    Yeh, W.L.4    Lin, W.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.