메뉴 건너뛰기




Volumn 64, Issue 6, 2009, Pages 787-794

Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography

Author keywords

CT angiography; Echocardiography; Left ventricular function; Left ventricular volume

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONGESTIVE CARDIOMYOPATHY; CONTRAST ECHOCARDIOGRAPHY; CONTROLLED STUDY; FEMALE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE VOLUME; HUMAN; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; SYSTOLIC DYSFUNCTION; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 74749100587     PISSN: 00015385     EISSN: None     Source Type: Journal    
DOI: 10.2143/AC.64.6.2044744     Document Type: Article
Times cited : (12)

References (28)
  • 2
    • 0000531635 scopus 로고    scopus 로고
    • Cardiovascular death and left ventricular remodeling two years after myocardial infarction: Baseline predictors and impact of long-term use of Captopril: information from the Survival and Ventricular Enlargement (SAVE) trial
    • St John Sutton M, Pfeffer MA, Moye L, Plappert T, Rouleau JL, Lamas G, Rouleau J, Parker JO, Arnold MO, Sussex B, Braunwald E. Cardiovascular death and left ventricular remodeling two years after myocardial infarction: baseline predictors and impact of long-term use of Captopril: information from the Survival and Ventricular Enlargement (SAVE) trial. Circulation 1997; 96: 3294-9.
    • (1997) Circulation , vol.96 , pp. 3294-3299
    • St John Sutton, M.1    Pfeffer, M.A.2    Moye, L.3    Plappert, T.4    Rouleau, J.L.5    Lamas, G.6    Rouleau, J.7    Parker, J.O.8    Arnold, M.O.9    Sussex, B.10    Braunwald, E.11
  • 3
    • 0031003333 scopus 로고    scopus 로고
    • Left ventricular dilatation and the risk of congestive heart failure in people without myocardial infarction
    • Vasan RS, Larson MG, Benjamin EJ, Evans JC, Levy D. Left ventricular dilatation and the risk of congestive heart failure in people without myocardial infarction. N Engl J Med 1997; 336: 1350-5.
    • (1997) N Engl J Med , vol.336 , pp. 1350-1355
    • Vasan, R.S.1    Larson, M.G.2    Benjamin, E.J.3    Evans, J.C.4    Levy, D.5
  • 5
    • 1842750672 scopus 로고    scopus 로고
    • Imaging of ventricular function by cardiovascular magnetic resonance
    • Rathi VK, Biederman RW Imaging of ventricular function by cardiovascular magnetic resonance. Curr Cardiol Rep 2004; 6: 55-61.
    • (2004) Curr Cardiol Rep , vol.6 , pp. 55-61
    • Rathi, V.K.1    Biederman, R.W.2
  • 6
    • 6344287927 scopus 로고    scopus 로고
    • Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    • Alfakih K, Reid S, Jones T, Sivananthan M. Assessment of ventricular function and mass by cardiac magnetic resonance imaging. Eur Radiol 2004; 14: 1813-22.
    • (2004) Eur Radiol , vol.14 , pp. 1813-1822
    • Alfakih, K.1    Reid, S.2    Jones, T.3    Sivananthan, M.4
  • 7
    • 1642499210 scopus 로고    scopus 로고
    • Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: Initial experience
    • Juergens KU, Grude M, Maintz D, Fallenberg EM, Wichter T, Heindel W, Fischbach R. Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 2004; 230: 403-10.
    • (2004) Radiology , vol.230 , pp. 403-410
    • Juergens, K.U.1    Grude, M.2    Maintz, D.3    Fallenberg, E.M.4    Wichter, T.5    Heindel, W.6    Fischbach, R.7
  • 8
    • 4444381394 scopus 로고    scopus 로고
    • Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: A comparison with magnetic resonance imaging
    • Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T. Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 2004; 44: 1030-5.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1030-1035
    • Malm, S.1    Frigstad, S.2    Sagberg, E.3    Larsson, H.4    Skjaerpe, T.5
  • 9
    • 27744481008 scopus 로고    scopus 로고
    • Improved accuracy of low-power contrast echocardiography for the assessment of left ventricular remodeling compared with unenhanced harmonic echocardiography after acute myocardial infarction: Comparison with cardiovascular magnetic resonance imaging
    • Lim TK, Burden L, Janardhanan R, Ping C, Moon J, Pennell D, Senior R. Improved accuracy of low-power contrast echocardiography for the assessment of left ventricular remodeling compared with unenhanced harmonic echocardiography after acute myocardial infarction: comparison with cardiovascular magnetic resonance imaging. J Am Soc Echocardiogr 2005; 18: 1203-7.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1203-1207
    • Lim, T.K.1    Burden, L.2    Janardhanan, R.3    Ping, C.4    Moon, J.5    Pennell, D.6    Senior, R.7
  • 10
    • 29244432482 scopus 로고    scopus 로고
    • Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005; 18: 1440-63.
    • Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005; 18: 1440-63.
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 12
  • 13
    • 45149083745 scopus 로고    scopus 로고
    • Assessment of left ventricular function: Comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function
    • Bansal D, Singh RM, Sarkar M, Sureddi R, McBreen KC, Griffis T, Sinha A, Mehta JL. Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function. Int J Cardiovasc Imaging 2008; 24: 327-9.
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 327-329
    • Bansal, D.1    Singh, R.M.2    Sarkar, M.3    Sureddi, R.4    McBreen, K.C.5    Griffis, T.6    Sinha, A.7    Mehta, J.L.8
  • 14
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Galuschky C, Schummers G, Lang RM, Nesser HJ. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 2006; 114: 654-61.
    • (2006) Circulation , vol.114 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3    Niel, J.4    Ebner, C.5    Steringer-Mascherbauer, R.6    Schmidt, F.7    Galuschky, C.8    Schummers, G.9    Lang, R.M.10    Nesser, H.J.11
  • 16
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality
    • Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A, Bruning R, Reiser MF. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 2001; 220: 712-7.
    • (2001) Radiology , vol.220 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3    Schoepf, U.J.4    Ohnesorge, B.5    Knez, A.6    Bruning, R.7    Reiser, M.F.8
  • 17
    • 0344826035 scopus 로고    scopus 로고
    • Assessment of left ventricular volumes using multidetector row computed tomography (MDCT): Phantom and human studies
    • Hosoi S, Mochizuki T, Miyagawa M, Shen Y, Murase K, Ikezoe J. Assessment of left ventricular volumes using multidetector row computed tomography (MDCT): phantom and human studies. Radiat Med 2003; 21: 62-7.
    • (2003) Radiat Med , vol.21 , pp. 62-67
    • Hosoi, S.1    Mochizuki, T.2    Miyagawa, M.3    Shen, Y.4    Murase, K.5    Ikezoe, J.6
  • 18
    • 0345689655 scopus 로고    scopus 로고
    • Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: Value of different image reconstruction algorithms in comparison to MRI
    • Mahnken AH, Spuentrup E, Niethammer M, Buecker A, Boese J, Wildberger JE, Flohr T, Sinha AM, Krombach GA, Gunther RW Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol 2003; 44: 604-11.
    • (2003) Acta Radiol , vol.44 , pp. 604-611
    • Mahnken, A.H.1    Spuentrup, E.2    Niethammer, M.3    Buecker, A.4    Boese, J.5    Wildberger, J.E.6    Flohr, T.7    Sinha, A.M.8    Krombach, G.A.9    Gunther, R.W.10
  • 19
    • 33847265364 scopus 로고    scopus 로고
    • Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: Comparison to magnetic resonance imaging
    • Schlosser T, Mohrs OK, Magedanz A, Voigtlander T, Schmermund A, Barkhausen J. Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging. Acta Radiol 2007; 48: 30-5.
    • (2007) Acta Radiol , vol.48 , pp. 30-35
    • Schlosser, T.1    Mohrs, O.K.2    Magedanz, A.3    Voigtlander, T.4    Schmermund, A.5    Barkhausen, J.6
  • 21
    • 33746663053 scopus 로고    scopus 로고
    • Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: A phantom study
    • Mahnken AH, Hohl C, Suess C, Bruder H, Muhlenbruch G, Das M, Gunther RW, Wildberger JE. Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study. Invest Radiol 2006; 41: 429-35.
    • (2006) Invest Radiol , vol.41 , pp. 429-435
    • Mahnken, A.H.1    Hohl, C.2    Suess, C.3    Bruder, H.4    Muhlenbruch, G.5    Das, M.6    Gunther, R.W.7    Wildberger, J.E.8
  • 22
    • 0141478720 scopus 로고    scopus 로고
    • Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: Comparison with magnetic resonance imaging
    • Grude M, Juergens KU, Wichter T, Paul M, Fallenberg EM, Muller JG, Heindel W, Breithardt G, Fischbach R. Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging. Invest Radiol 2003; 38: 653-61.
    • (2003) Invest Radiol , vol.38 , pp. 653-661
    • Grude, M.1    Juergens, K.U.2    Wichter, T.3    Paul, M.4    Fallenberg, E.M.5    Muller, J.G.6    Heindel, W.7    Breithardt, G.8    Fischbach, R.9
  • 27
    • 74749087146 scopus 로고    scopus 로고
    • The European Agency for the Evaluation of Medical Products, Available at
    • The European Agency for the Evaluation of Medical Products. The EMEA page. Available at: http://www.emea.europa.eu/pdfs/human/press/pus/021204en.pdf
    • The EMEA page
  • 28
    • 74749091760 scopus 로고    scopus 로고
    • Available at
    • U.S. Food and Drug Administration. The FDA Page. Available at: http://www.fda.gov/CDER/drug/infopage/microbubble/default.htm
    • The FDA Page


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.