메뉴 건너뛰기




Volumn , Issue , 2009, Pages 153-158

Diagnosis of a continuous stirred tank reactor using Kalman filter

Author keywords

Actuator and sensor faults; CSTR; Fault detection and isolation; Kalman filter; Model parametric uncertainties

Indexed keywords

CHEMICAL PROCESS; COMPLEX SYSTEMS; CONTINUOUS STIRRED TANK REACTOR; EXTERNAL DISTURBANCES; FAULT DETECTION AND ISOLATION; INTERPOLATION ERROR; KALMAN FILTER MODEL; NUMERICAL SIMULATION; PARAMETRIC UNCERTAINTIES; SENSOR FAULT; STEADY STATE; UNPREDICTABLE FAULTS;

EID: 74549203870     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CSSim.2009.22     Document Type: Conference Paper
Times cited : (9)

References (10)
  • 1
    • 0038067735 scopus 로고    scopus 로고
    • Multi-linear model-based fault detection during process transitions
    • A. Bhagwat, R. Srinivasan, and P.R. Krishnaswamy, "Multi-linear model-based fault detection during process transitions", Chemical Engineering Science, vol.58, 2003, pp. 1649 - 1670.
    • (2003) Chemical Engineering Science , vol.58 , pp. 1649-1670
    • Bhagwat, A.1    Srinivasan, R.2    Krishnaswamy, P.R.3
  • 2
    • 0021468997 scopus 로고
    • Process Fault Detection Based on Modeling and Estimation Methods A Survey
    • R. Isermann, "Process Fault Detection Based on Modeling and Estimation Methods A Survey", Automatica, , Vol. 20, No. 4, 1984, pp. 37-40.
    • (1984) Automatica , vol.20 , Issue.4 , pp. 37-40
    • Isermann, R.1
  • 4
    • 0038754915 scopus 로고    scopus 로고
    • Reactor noise measurements in the safety and regulating systems of CANDU stations
    • O. Gockler, "Reactor noise measurements in the safety and regulating systems of CANDU stations", Progress in Nuclear Energy, Vol. 43, No. 1-4, 2003, pp. 75-82.
    • (2003) Progress in Nuclear Energy , vol.43 , Issue.1-4 , pp. 75-82
    • Gockler, O.1
  • 5
    • 0031147879 scopus 로고    scopus 로고
    • Observer-Based Fault Detection and Isolation: Robustness and Applications
    • R. J. Patton, and J. Chen, "Observer-Based Fault Detection and Isolation: Robustness and Applications", Control Engineering Practice, Vol. 5, 5, 1997, Pages 671-682.
    • (1997) Control Engineering Practice , vol.5 , Issue.5 , pp. 671-682
    • Patton, R.J.1    Chen, J.2
  • 6
    • 0030201126 scopus 로고    scopus 로고
    • Ouput Feedback Control of a Stirred Tank Reactor
    • K. Adebekun, "Ouput Feedback Control of a Stirred Tank Reactor", Elsevier Science Ltd, 1996, pp. 1017-1021.
    • (1996) Elsevier Science Ltd , pp. 1017-1021
    • Adebekun, K.1
  • 7
    • 74549220508 scopus 로고    scopus 로고
    • A. Hsoumi, R. El Harabi, S. Bel Hadj Ali Naoui, M.N. Abdelkrim, Luenberger Observer based Sensor and Actuator Fault Detection for Chemical Reactor, accepted in 2nd IFAC International Conference on Intelligent Control Systems and Signal Processing (ICONS 2009), 21 - 23 September 2009, Istanbul, Turkey.
    • A. Hsoumi, R. El Harabi, S. Bel Hadj Ali Naoui, M.N. Abdelkrim, "Luenberger Observer based Sensor and Actuator Fault Detection for Chemical Reactor", accepted in 2nd IFAC International Conference on Intelligent Control Systems and Signal Processing (ICONS 2009), 21 - 23 September 2009, Istanbul, Turkey.
  • 8
    • 33644644480 scopus 로고    scopus 로고
    • Sensor fault diagnosis for nonlinear processes with parametric uncertainties
    • S. Rajaraman, J. Hahn, and M. S. Mannan, "Sensor fault diagnosis for nonlinear processes with parametric uncertainties", Journal of Hazardous Materials, 2006, pp. 1-8.
    • (2006) Journal of Hazardous Materials , pp. 1-8
    • Rajaraman, S.1    Hahn, J.2    Mannan, M.S.3
  • 9
    • 4644352427 scopus 로고    scopus 로고
    • Fault detection by using the innovation signal: Application to an exothermic reaction
    • Y. Chetouani, "Fault detection by using the innovation signal: application to an exothermic reaction", Chemical Engineering and Processing, 2004, pp. 1579-1585.
    • (2004) Chemical Engineering and Processing , pp. 1579-1585
    • Chetouani, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.