메뉴 건너뛰기




Volumn 43, Issue 1-4 SPEC, 2003, Pages 75-82

Reactor noise measurements in the safety and regulating systems of CANDU stations

Author keywords

Detector fault monitoring; Detector tube vibration; Flow transmitters; Fuel channel vibration; In core flux detectors; Reactor noise analysis; Response time

Indexed keywords

ACCIDENT PREVENTION; COOLANTS; FLUXES; IONIZATION CHAMBERS; NUCLEAR POWER PLANTS; PARAMETER ESTIMATION; SIGNAL NOISE MEASUREMENT; TRANSMITTERS; VIBRATIONS (MECHANICAL);

EID: 0038754915     PISSN: 01491970     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0149-1970(03)00008-8     Document Type: Article
Times cited : (10)

References (10)
  • 1
    • 32044445409 scopus 로고    scopus 로고
    • Statistics of flow noise in loop DNGS 3-68334-FT3J, measured with various line length and transmitter types - Measurement data report
    • NK38-REP-68334-985103-R00
    • Glöckler O. (1998a), Statistics of Flow Noise in Loop DNGS 3-68334-FT3J, Measured with Various Line Length and Transmitter Types - Measurement Data Report, NK38-REP-68334-985103-R00.
    • (1998)
    • Glöckler, O.1
  • 2
    • 24244456497 scopus 로고    scopus 로고
    • DNGS flow transmitter noise analysis report, units 1-4 "As-left", October 1997
    • Glöckler O. (1998b), DNGS Flow Transmitter Noise Analysis Report, Units 1-4 "As-Left", October 1997, Report NK38-03610.02-985022/23/24/25-R00.
    • (1998) Report NK38-03610.02-985022/23/24/25-R00
    • Glöckler, O.1
  • 3
    • 85031187401 scopus 로고    scopus 로고
    • SDSI low gross flow noise monitoring and flow transmitter replacement on loops 8-63724 F3D and F2E in pickering-B unit 8
    • Report NK30-REP-63724-10001-R00
    • Glöckler O. (1999), SDSI Low Gross Flow Noise Monitoring and Flow Transmitter Replacement on Loops 8-63724 F3D and F2E in Pickering-B Unit 8, Report NK30-REP-63724-10001-R00.
    • (1999)
    • Glöckler, O.1
  • 4
    • 24244474435 scopus 로고    scopus 로고
    • Estimating the response time of SDS pressure/flow transmitters and their sensing lines via in-situ at-power noise measurements in Bruce-B unit 6
    • Report NK29-REP-63700-00001-R00
    • Glöckler O. (2000a), Estimating the Response Time of SDS Pressure/Flow Transmitters and Their Sensing Lines via In-Situ At-Power Noise Measurements in Bruce-B Unit 6, Report NK29-REP-63700-00001-R00.
    • (2000)
    • Glöckler, O.1
  • 5
    • 24244463242 scopus 로고    scopus 로고
    • Estimating the moderator transit times between moderator RTDs and their response time via in-situ at-power noise measurements in Bruce-B unit 8
    • Report NK29-REP-63210-00001-R00
    • Glöcker O. (2000b), Estimating the Moderator Transit Times Between Moderator RTDs and Their Response Time via In-Situ At-Power Noise Measurements in Bruce-B Unit 8, Report NK29-REP-63210-00001-R00.
    • (2000)
    • Glöckler, O.1
  • 6
    • 4243324097 scopus 로고    scopus 로고
    • Response times of SDS1 LGF loops FT-2D and FT-4D measured in-situ in pickering-B unit 6
    • Report NK30-REP-63724-00001-R00
    • Glöckler O. (2001), Response Times of SDS1 LGF Loops FT-2D and FT-4D Measured In-Situ in Pickering-B Unit 6, Report NK30-REP-63724-00001-R00.
    • (2001)
    • Glöckler, O.1
  • 7
    • 4243543310 scopus 로고    scopus 로고
    • Validation of the response times of bailey flow transmitter installed in SDS2 darlington unit 3
    • Report NK38-REP-68334-10003-R00
    • Glöckler O. (2002), Validation of the Response Times of Bailey Flow Transmitter Installed in SDS2 Darlington Unit 3, Report NK38-REP-68334-10003-R00.
    • (2002)
    • Glöckler, O.1
  • 8
    • 4243475768 scopus 로고    scopus 로고
    • Validation of the response time tester
    • Report NK38-REP-68334-10004-R00
    • Hinds H.W. and Glöckler O. (2002), Validation of the Response Time Tester, Report NK38-REP-68334-10004-R00.
    • (2002)
    • Hinds, H.W.1    Glöckler, O.2
  • 9
    • 85031179775 scopus 로고    scopus 로고
    • Validation of the auto-power-spectral-density method of determining the response time of Rosemount, Gould, and Bailey flow transmitters
    • Report COG-98-323, AECL, Chalk River
    • Hinds H.W., Koslowsky V., Kumli P. (1998), Validation of the Auto-Power-Spectral-Density Method of Determining the Response Time of Rosemount, Gould, and Bailey Flow Transmitters, Report COG-98-323, AECL, Chalk River.
    • (1998)
    • Hinds, H.W.1    Koslowsky, V.2    Kumli, P.3
  • 10
    • 4243324094 scopus 로고    scopus 로고
    • Effect of instrument-line length on differential pressure measurements
    • Report CS-NAH-TN-33
    • Koslowsky V., Hinds H.W., Glöckler O. (1998), Effect of Instrument-Line Length on Differential Pressure Measurements, Report CS-NAH-TN-33.
    • (1998)
    • Koslowsky, V.1    Hinds, H.W.2    Glöckler, O.3