Volumn , Issue , 2009, Pages

A new strategy for condition monitoring of adjustable speed induction machine drive systems

Author keywords

Adjustable speed drive; Broken rotor bar; Capacitance; Condition; Diagnostics; Dissipation factor; Electrolytic capacitor; Equivalent series resistance; High resistance connection; Insulation resistance; Inter laminar insulation failure; Monitoring; Power cable; Stator core; Stator winding insulation

Indexed keywords

ADJUSTABLE SPEED DRIVES; BROKEN ROTOR BAR; CONDITION; DISSIPATION FACTORS; EQUIVALENT SERIES RESISTANCE; HIGH RESISTANCE; HIGH RESISTANCE CONNECTION; INSULATION FAILURES; INSULATION RESISTANCE; POWER CABLES; STATOR CORE; STATOR WINDING;

EID: 74349111888     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/DEMPED.2009.5292792     Document Type: Conference Paper
Times cited : (10)

References (35)
  • 3
    • 0026927716 scopus 로고
    • Transient effects in application of PWM inverters to induction motors
    • E. Persson, "Transient effects in application of PWM inverters to induction motors," IEEE Trans. on Ind. Appl., vol. 28, no. 5, pp. 1095-1101, 1992.
    • (1992) IEEE Trans. on Ind. Appl. , vol.28 , Issue.5 , pp. 1095-1101
    • Persson, E.1
  • 4
    • 0034275724 scopus 로고    scopus 로고
    • Inverter-fed drives: Which motors are at risk?
    • G. Stone, S. Campbell, S. Tetreault, "Inverter-fed drives: which motors are at risk?," IEEE Ind. Appl. Mag., vol. 6, no. 5, pp. 17-22, 2004.
    • (2004) IEEE Ind. Appl. Mag. , vol.6 , Issue.5 , pp. 17-22
    • Stone, G.1    Campbell, S.2    Tetreault, S.3
  • 6
    • 0030108167 scopus 로고    scopus 로고
    • Source of induction motor bearing current caused by PWM inverters
    • S. Chen, T.A. Lipo, D. Fitzgerald, "Source of induction motor bearing current caused by PWM inverters," IEEE Trans. on Ener. Conv., vol. 11, no. 1, pp. 25-32, 1996.
    • (1996) IEEE Trans. on Ener. Conv. , vol.11 , Issue.1 , pp. 25-32
    • Chen, S.1    Lipo, T.A.2    Fitzgerald, D.3
  • 7
    • 84866636568 scopus 로고
    • Reliability prediction of electronic equipment
    • Feb. 28
    • Military Handbook 217F, "Reliability prediction of electronic equipment," Feb. 28, 1995.
    • (1995) Military Handbook 217F
  • 9
    • 0027680187 scopus 로고
    • Use of ESR for deterioration diagnosis of electrolytic capacitor
    • Oct.
    • K. Harada, A. Katsuki, and M. Fujiwara, "Use of ESR for deterioration diagnosis of electrolytic capacitor," IEEE Trans. on Power Electr., vol. 8, no. 4, pp. 355-361, Oct. 1993.
    • (1993) IEEE Trans. on Power Electr. , vol.8 , Issue.4 , pp. 355-361
    • Harada, K.1    Katsuki, A.2    Fujiwara, M.3
  • 10
    • 46449130570 scopus 로고    scopus 로고
    • Real-time condition monitoring of the electrolytic capacitors for power electronics applications
    • A. M. Imam, T. G. Habetler, R. G. Harley, and D.M. Divan, "Real-Time Condition Monitoring of the Electrolytic Capacitors for Power Electronics Applications," Proc. of Applied Pwr. Elec. Conf., pp. 1057-1061, 2007.
    • (2007) Proc. of Applied Pwr. Elec. Conf. , pp. 1057-1061
    • Imam, A.M.1    Habetler, T.G.2    Harley, R.G.3    Divan, D.M.4
  • 11
    • 29244457640 scopus 로고    scopus 로고
    • Life prediction modeling of bus capacitors in ac variable-frequency drives
    • Nov./Dec.
    • M.L. Gasperi, "Life prediction modeling of bus capacitors in ac variable-frequency drives," IEEE Trans. on Ind. Appl., vol. 41, no. 6, pp. 1430-1435, Nov./Dec. 2005.
    • (2005) IEEE Trans. on Ind. Appl. , vol.41 , Issue.6 , pp. 1430-1435
    • Gasperi, M.L.1
  • 12
    • 0032203504 scopus 로고    scopus 로고
    • Failure prediction of electrolytic capacitors during operation of a switchmode power supply
    • Nov.
    • A. Layhani, P. Venet, G. Grellet, and P.J. Viverge, "Failure prediction of electrolytic capacitors during operation of a switchmode power supply," IEEE Trans. on Power Electr., vol. 13, no. 6, pp. 1199-1207, Nov. 1998.
    • (1998) IEEE Trans. on Power Electr. , vol.13 , Issue.6 , pp. 1199-1207
    • Layhani, A.1    Venet, P.2    Grellet, G.3    Viverge, P.J.4
  • 13
    • 0036129954 scopus 로고    scopus 로고
    • Realization of a smart electrolytic capacitor circuit
    • Jan./Feb.
    • P. Venet, F. Perisse, M.H. El-Husseini, and G. Rojat, "Realization of a smart electrolytic capacitor circuit," IEEE Ind. Appl. Mag., vol. 8, no. 1, pp. 16-20, Jan./Feb. 2002.
    • (2002) IEEE Ind. Appl. Mag. , vol.8 , Issue.1 , pp. 16-20
    • Venet, P.1    Perisse, F.2    El-Husseini, M.H.3    Rojat, G.4
  • 14
    • 53349109174 scopus 로고    scopus 로고
    • Condition monitoring of DC link electrolytic capacitors in adjustable speed drives
    • Sept./Oct.
    • K. Lee, M. Kim, J. Yoon, S.B. Lee, and J. Yoo, "Condition Monitoring of DC Link Electrolytic Capacitors in Adjustable Speed Drives," IEEE Trans. on Ind. Appl., vol. 44, no. 5, pp. 1606-1613, Sept./Oct. 2008.
    • (2008) IEEE Trans. on Ind. Appl. , vol.44 , Issue.5 , pp. 1606-1613
    • Lee, K.1    Kim, M.2    Yoon, J.3    Lee, S.B.4    Yoo, J.5
  • 17
    • 33749041322 scopus 로고    scopus 로고
    • Detection of high-resistance motor connections using symmetrical component analysis and neural networks
    • Atlanta, GA
    • R.S. Colby, "Detection of high-resistance motor connections using symmetrical component analysis and neural networks," Proc. of IEEE SDEMPED, pp. 2-6, Atlanta, GA, 2003.
    • (2003) Proc. of IEEE SDEMPED , pp. 2-6
    • Colby, R.S.1
  • 18
    • 57949104238 scopus 로고    scopus 로고
    • Automated monitoring of high-resistance connections in the electrical distribution system of industrial facilities
    • Oct.
    • J. Yoon, J. Yun, S.B. Lee, and E.J. Wiedenbrug, "Automated Monitoring of High-Resistance Connections in the Electrical Distribution System of Industrial Facilities," Proc. of IEEE IAS Ann. Meet., Oct. 2008.
    • (2008) Proc. of IEEE IAS Ann. Meet.
    • Yoon, J.1    Yun, J.2    Lee, S.B.3    Wiedenbrug, E.J.4
  • 21
    • 41949093228 scopus 로고    scopus 로고
    • An advanced technique for monitoring the condition of stator winding groundwall insulation for inverter-fed machines
    • Mar./Apr.
    • J. Yang, J. Cho, S.B. Lee, and J. Yoo, "An Advanced Technique for Monitoring the Condition of Stator Winding Groundwall Insulation for Inverter-fed Machines," IEEE Trans. on Ind. Appl., vol. 44, no. 2, pp. 555-564, Mar./Apr. 2008.
    • (2008) IEEE Trans. on Ind. Appl. , vol.44 , Issue.2 , pp. 555-564
    • Yang, J.1    Cho, J.2    Lee, S.B.3    Yoo, J.4
  • 22
    • 74349084495 scopus 로고    scopus 로고
    • Can energy efficient motors be wound satisfactorily?
    • Electrical Apparatus Service Association, Inc
    • Can energy efficient motors be wound satisfactorily?, EASA tech. note no. 26, Electrical Apparatus Service Association, Inc, 1999.
    • (1999) EASA Tech. Note No. 26
  • 24
    • 74349083994 scopus 로고    scopus 로고
    • Stator core testing
    • Electrical Apparatus Service Association, Inc
    • Stator core testing, EASA tech. note no. 17, Electrical Apparatus Service Association, Inc, 2002.
    • (2002) EASA Tech. Note No. 17
  • 27
    • 57749196360 scopus 로고    scopus 로고
    • Advances in diagnostics techniques for induction machines
    • Dec.
    • A. Bellini, F. Filippetti, C. Tassoni, & G.A. Capolino, "Advances in Diagnostics Techniques for Induction Machines," IEEE Trans. on Ind. Elec., vol. 55, no. 12, pp. 4109-4126, Dec. 2008.
    • (2008) IEEE Trans. on Ind. Elec. , vol.55 , Issue.12 , pp. 4109-4126
    • Bellini, A.1    Filippetti, F.2    Tassoni, C.3    Capolino, G.A.4
  • 28
    • 0034272250 scopus 로고    scopus 로고
    • Closed-loop control impact on the diagnosis of induction motors faults
    • Sept./Oct.
    • A. Bellini, F. Filippetti, G. Franceschini, & C. Tassoni, "Closed-loop control impact on the diagnosis of induction motors faults," IEEE Trans. on Ind. Appl., vol. 36, no. 5, pp. 1318-1329, Sept./Oct. 2000.
    • (2000) IEEE Trans. on Ind. Appl. , vol.36 , Issue.5 , pp. 1318-1329
    • Bellini, A.1    Filippetti, F.2    Franceschini, G.3    Tassoni, C.4
  • 29
    • 34948813113 scopus 로고    scopus 로고
    • Diagnosis of rotor faults in closed-loop induction motors drives
    • S.M.A. Cruz, & A.J.M. Cardoso, "Diagnosis of rotor faults in closed-loop induction motors drives," proceedings of IEEE IAS Annual Meeting, vol. 5, pp. 2346-2353, 2006.
    • (2006) Proceedings of IEEE IAS Annual Meeting , vol.5 , pp. 2346-2353
    • Cruz, S.M.A.1    Cardoso, A.J.M.2
  • 30
    • 0034294031 scopus 로고    scopus 로고
    • Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-the vienna monitoring method
    • Oct.
    • C. Kral, R. Wieser, F. Pirker, & M. Schagginger, "Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-The Vienna monitoring method," IEEE Trans. on Ind. Elec., vol. 47, no. 5, pp. 1042-1050, Oct. 2000.
    • (2000) IEEE Trans. on Ind. Elec. , vol.47 , Issue.5 , pp. 1042-1050
    • Kral, C.1    Wieser, R.2    Pirker, F.3    Schagginger, M.4
  • 31
    • 3242877165 scopus 로고    scopus 로고
    • On-line diagnosis of inverter-fed induction machines using high-frequency signal injection
    • July/Aug.
    • F. Briz, M.W. Degner, A.B. Diez, & J.M. Guerrero, "On-line diagnosis of inverter-fed induction machines using high-frequency signal injection," IEEE Trans. on Ind. Appl., vol. 40, no. 4, pp. 1153-1161, July/Aug. 2004.
    • (2004) IEEE Trans. on Ind. Appl. , vol.40 , Issue.4 , pp. 1153-1161
    • Briz, F.1    Degner, M.W.2    Diez, A.B.3    Guerrero, J.M.4
  • 32
    • 28444455860 scopus 로고    scopus 로고
    • Squirrel cage rotor testing
    • T. Bishop, "Squirrel cage rotor testing," EASA Convention, 2003.
    • (2003) EASA Convention
    • Bishop, T.1
  • 33
    • 0036577784 scopus 로고    scopus 로고
    • Detection of rotor faults in squirrelcage induction machines at standstill for batch tests by means of Vienna monitoring method
    • May/June
    • C. Kral, F. Pirker, & G. Pascoli, "Detection of rotor faults in squirrelcage induction machines at standstill for batch tests by means of Vienna monitoring method," IEEE Trans. on Ind. Appl., vol. 38, no. 3, pp. 618-624, May/June 2002.
    • (2002) IEEE Trans. on Ind. Appl. , vol.38 , Issue.3 , pp. 618-624
    • Kral, C.1    Pirker, F.2    Pascoli, G.3
  • 34
    • 66449087719 scopus 로고    scopus 로고
    • DSP-based sensorless electric motor fault diagnosis tools for electric and hybrid electric vehicle powertrain applications
    • B. Akin, B. Ozturk, H. Toliyat, & M. Rayner, "DSP-based sensorless electric motor fault diagnosis tools for electric and hybrid electric vehicle powertrain applications," IEEE Trans. on Veh. Tech., vol. 58, no. 1, 2009.
    • (2009) IEEE Trans. on Veh. Tech. , vol.58 , Issue.1
    • Akin, B.1    Ozturk, B.2    Toliyat, H.3    Rayner, M.4
  • 35
    • 10244227902 scopus 로고    scopus 로고
    • Detection of induction machines rotor faults at standstill using signals injection
    • Nov./Dec.
    • C. Demian, A. Mpanda-Mabwe, H. Henao, & G.A. Capolino, "Detection of induction machines rotor faults at standstill using signals injection," IEEE Trans. on Ind. Appl., vol. 40, no. 6, pp. 1550-1559, Nov./Dec. 2004.
    • (2004) IEEE Trans. on Ind. Appl. , vol.40 , Issue.6 , pp. 1550-1559
    • Demian, C.1    Mpanda-Mabwe, A.2    Henao, H.3    Capolino, G.A.4