메뉴 건너뛰기




Volumn 63, Issue 6, 2009, Pages 624-631

Reconstruction of orbital floor fractures: Comparison of individual prefabricated titanium implants and calvarial bone grafts

Author keywords

Enophthalmos; Fractures; Image reconstruction; Material; Orbital floor

Indexed keywords

TITANIUM;

EID: 74249119237     PISSN: 01487043     EISSN: None     Source Type: Journal    
DOI: 10.1097/SAP.0b013e3181999df3     Document Type: Article
Times cited : (38)

References (22)
  • 1
    • 0035449949 scopus 로고    scopus 로고
    • A current 10-year retrospective survey of 199 surgically treated orbital floor fractures in a nonurban tertiary care center
    • Tong L, Bauer RJ, Buchman SR. A current 10-year retrospective survey of 199 surgically treated orbital floor fractures in a nonurban tertiary care center. Plast Reconstr Surg. 2001;108:612-621.
    • (2001) Plast Reconstr Surg , vol.108 , pp. 612-621
    • Tong, L.1    Bauer, R.J.2    Buchman, S.R.3
  • 2
    • 0036288404 scopus 로고    scopus 로고
    • Clinical recommendations for repair of isolated orbital floor fractures: An evidence-based analysis
    • Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology. 2002;109:1207-1210.
    • (2002) Ophthalmology , vol.109 , pp. 1207-1210
    • Burnstine, M.A.1
  • 3
    • 18044385167 scopus 로고    scopus 로고
    • Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (ethisorb): A retrospective study
    • Buchel P, Rahal A, Seto C, et al. Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (ethisorb): a retrospective study. J Oral Maxillofac Surg. 2005;63:646-650.
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 646-650
    • Buchel, P.1    Rahal, A.2    Seto, C.3
  • 4
    • 37849039817 scopus 로고    scopus 로고
    • Comprehensive management of orbital fractures
    • Cole P, Boyd V, Banerji S, et al. Comprehensive management of orbital fractures. Plast Reconstr Surg. 2007;120:57S- 63S.
    • (2007) Plast Reconstr Surg , vol.120
    • Cole, P.1    Boyd, V.2    Banerji, S.3
  • 5
    • 0036839099 scopus 로고    scopus 로고
    • Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity
    • Gellrich NC, Schramm A, Hammer B, et al. Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity. Plast Reconstr Surg. 2002;110:1417-1429.
    • (2002) Plast Reconstr Surg , vol.110 , pp. 1417-1429
    • Gellrich, N.C.1    Schramm, A.2    Hammer, B.3
  • 6
    • 4644239305 scopus 로고    scopus 로고
    • Evaluation of ocular changes secondary to blowout fractures
    • Mazock JB, Schow SR, Triplett RG. Evaluation of ocular changes secondary to blowout fractures. J Oral Maxillofac Surg. 2004;62:1298-1302.
    • (2004) J Oral Maxillofac Surg , vol.62 , pp. 1298-1302
    • Mazock, J.B.1    Schow, S.R.2    Triplett, R.G.3
  • 7
    • 0041358745 scopus 로고    scopus 로고
    • A prospective study of orbital fracture sequelae after change of surgical routines
    • Folkestad L, Granstrom G. A prospective study of orbital fracture sequelae after change of surgical routines. J Oral Maxillofac Surg. 2003;61:1038-1044.
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 1038-1044
    • Folkestad, L.1    Granstrom, G.2
  • 8
    • 0031923249 scopus 로고    scopus 로고
    • Repair of orbital blow-out fractures with nasoseptal cartilage
    • Lai A, Gliklich RE, Rubin PA. Repair of orbital blow-out fractures with nasoseptal cartilage. Laryngoscope. 1998;108:645-650.
    • (1998) Laryngoscope , vol.108 , pp. 645-650
    • Lai, A.1    Gliklich, R.E.2    Rubin, P.A.3
  • 9
    • 33646116820 scopus 로고    scopus 로고
    • Repair of traumatic orbital wall defects using conchal cartilage
    • Ozyazgan I, Eskitascioglu T, Baykan H, et al. Repair of traumatic orbital wall defects using conchal cartilage. Plast Reconstr Surg. 2006;117:1269-1276.
    • (2006) Plast Reconstr Surg , vol.117 , pp. 1269-1276
    • Ozyazgan, I.1    Eskitascioglu, T.2    Baykan, H.3
  • 10
    • 14544267231 scopus 로고    scopus 로고
    • Cranial bone grafting for orbital reconstruction: Is it still the best?
    • Kelly CP, Cohen AJ, Yavuzer R, et al. Cranial bone grafting for orbital reconstruction: is it still the best? J Craniofac Surg. 2005;16:181-185.
    • (2005) J Craniofac Surg , vol.16 , pp. 181-185
    • Kelly, C.P.1    Cohen, A.J.2    Yavuzer, R.3
  • 11
    • 0035496588 scopus 로고    scopus 로고
    • Correction of severe enophthalmos with titanium mesh
    • Siritongtaworn P. Correction of severe enophthalmos with titanium mesh. J Med Assoc Thai. 2001;84:S485-S490.
    • (2001) J Med Assoc Thai , vol.84
    • Siritongtaworn, P.1
  • 12
    • 33646111022 scopus 로고    scopus 로고
    • Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants
    • Nam SB, Bae YC, Moon JS, et al. Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants. Ann Plast Surg. 2006;56:263-267.
    • (2006) Ann Plast Surg , vol.56 , pp. 263-267
    • Nam, S.B.1    Bae, Y.C.2    Moon, J.S.3
  • 13
    • 4744358692 scopus 로고    scopus 로고
    • Biomaterials for reconstruction of the internal orbit
    • Potter JK, Ellis E. Biomaterials for reconstruction of the internal orbit. J Oral Maxillofac Surg. 2004;62:1280-1297.
    • (2004) J Oral Maxillofac Surg , vol.62 , pp. 1280-1297
    • Potter, J.K.1    Ellis, E.2
  • 15
    • 33750356472 scopus 로고    scopus 로고
    • Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures
    • Schon R, Metzger MC, Zizelmann C, et al. Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures. Int J Oral Maxillofac Surg. 2006;35:990-995.
    • (2006) Int J Oral Maxillofac Surg , vol.35 , pp. 990-995
    • Schon, R.1    Metzger, M.C.2    Zizelmann, C.3
  • 16
    • 33847183545 scopus 로고    scopus 로고
    • Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures
    • Metzger MC, Schon R, Zizelmann C, et al. Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures. Plast Reconstr Surg. 2007;119:969-976.
    • (2007) Plast Reconstr Surg , vol.119 , pp. 969-976
    • Metzger, M.C.1    Schon, R.2    Zizelmann, C.3
  • 17
    • 42049107526 scopus 로고    scopus 로고
    • Posttraumatic enophthalmos: Etiology, principles of reconstruction, and correction
    • Clauser L, Galie M, Pagliaro F, et al. Posttraumatic enophthalmos: etiology, principles of reconstruction, and correction. J Craniofac Surg. 2008;19:351-359.
    • (2008) J Craniofac Surg , vol.19 , pp. 351-359
    • Clauser, L.1    Galie, M.2    Pagliaro, F.3
  • 18
    • 0034278121 scopus 로고    scopus 로고
    • Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos
    • Ramieri G, Spada MC, Bianchi SD, et al. Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos. Dentomaxillofac Rad. 2000;29:302-311.
    • (2000) Dentomaxillofac Rad , vol.29 , pp. 302-311
    • Ramieri, G.1    Spada, M.C.2    Bianchi, S.D.3
  • 19
    • 0021956772 scopus 로고
    • Orbital volume measurements in enophthalmos using threedimensional CT imaging
    • Bite U, Jackson IT, Forbes GS. Orbital volume measurements in enophthalmos using threedimensional CT imaging. Plast Reconstr Surg. 1985;75:502-508.
    • (1985) Plast Reconstr Surg , vol.75 , pp. 502-508
    • Bite, U.1    Jackson, I.T.2    Forbes, G.S.3
  • 20
    • 0037381327 scopus 로고    scopus 로고
    • Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh
    • Ellis E, Tan YH. Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh. J Oral Maxillofac Surg. 2003;61:442-453.
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 442-453
    • Ellis, E.1    Tan, Y.H.2
  • 21
    • 41649083953 scopus 로고    scopus 로고
    • A versatile virtual prototyping system for rapid product development
    • Choi SH, Cheung HH. A versatile virtual prototyping system for rapid product development. Comput Ind. 2008;59:477-488.
    • (2008) Comput Ind , vol.59 , pp. 477-488
    • Choi, S.H.1    Cheung, H.H.2
  • 22
    • 42049101190 scopus 로고    scopus 로고
    • Accuracy of virtual reality and stereolithographic models in maxillo-facial surgical planning
    • Robiony M, Salvo I, Costa F, et al. Accuracy of virtual reality and stereolithographic models in maxillo-facial surgical planning. J Craniofac Surg. 2008;19:482-489.
    • (2008) J Craniofac Surg , vol.19 , pp. 482-489
    • Robiony, M.1    Salvo, I.2    Costa, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.