-
1
-
-
0022611156
-
Studies on enophthalmos: II. The measurement of orbital injuries by quantitative computed tomography
-
P.N. Manson, A. Grivas, A. Rosenbaum Studies on enophthalmos: II. The measurement of orbital injuries by quantitative computed tomography Plast Reconstr Surg 77 1986 203
-
(1986)
Plast Reconstr Surg
, vol.77
, pp. 203
-
-
Manson, P.N.1
Grivas, A.2
Rosenbaum, A.3
-
2
-
-
0021956772
-
Orbital volume measurements in enophthalmos using three-REF CT imaging
-
U. Bite, It. Jackson, G.S. Forbes Orbital volume measurements in enophthalmos using three-REF CT imaging Plast Reconstr Surg 75 1985 502
-
(1985)
Plast Reconstr Surg
, vol.75
, pp. 502
-
-
Bite, U.1
Jackson, It.2
Forbes, G.S.3
-
3
-
-
0027490077
-
A comparison of microscrew and suture fixation of porous high density polyethylene orbital floor implants
-
R.H. Haug, D. Kimberly, J.P. Bradick A comparison of microscrew and suture fixation of porous high density polyethylene orbital floor implants J Oral Maxillofac Surg 51 1993 1217
-
(1993)
J Oral Maxillofac Surg
, vol.51
, pp. 1217
-
-
Haug, R.H.1
Kimberly, D.2
Bradick, J.P.3
-
4
-
-
0030855970
-
Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: A comprehensive review of the literature
-
P.J. Rubin, M.J. Yaremchuck Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery A comprehensive review of the literature Plast Reconstr Surg 100 1997 1336
-
(1997)
Plast Reconstr Surg
, vol.100
, pp. 1336
-
-
Rubin, P.J.1
Yaremchuck, M.J.2
-
5
-
-
0013809806
-
The use of alloplastics: In 45 cases of orbital floor reconstruction
-
C. Browning, R.V. Walker The use of alloplastics In 45 cases of orbital floor reconstruction Am J Ophthalmol 60 1965 684
-
(1965)
Am J Ophthalmol
, vol.60
, pp. 684
-
-
Browning, C.1
Walker, R.V.2
-
7
-
-
0006717871
-
Study and use of synthetic materials such as silicone and Teflon as subcutaneous prostheses
-
J.B. Brown, M.P. Fryer, D.A. Ohlwiler Study and use of synthetic materials such as silicone and Teflon as subcutaneous prostheses Plast Reconstr Surg 26 1960 264
-
(1960)
Plast Reconstr Surg
, vol.26
, pp. 264
-
-
Brown, J.B.1
Fryer, M.P.2
Ohlwiler, D.A.3
-
8
-
-
0023711352
-
Orbital floor reconstruction with lyophilized dura
-
P.D. Waite, J.T. Clantons Orbital floor reconstruction with lyophilized dura J Oral Maxillofac Surg 46 1988 727
-
(1988)
J Oral Maxillofac Surg
, vol.46
, pp. 727
-
-
Waite, P.D.1
Clantons, J.T.2
-
9
-
-
0027956955
-
Experimental evaluation of expanded polytetrafluoroethylene for reconstruction of orbital floor defects
-
L.J. Hanson, M.G. Donovan, J.W. Hellstein Experimental evaluation of expanded polytetrafluoroethylene for reconstruction of orbital floor defects J Oral Maxillofac Surg 52 1994 1050
-
(1994)
J Oral Maxillofac Surg
, vol.52
, pp. 1050
-
-
Hanson, L.J.1
Donovan, M.G.2
Hellstein, J.W.3
-
11
-
-
0026772898
-
Evaluation of a collagen/hydroxylapatite implant for orbital reconstructive surgery
-
M. Kazim, J.A. Katowitz, M. Fallon Evaluation of a collagen/ hydroxylapatite implant for orbital reconstructive surgery Ophthal Plast Reconstr Surg 8 1992 94
-
(1992)
Ophthal Plast Reconstr Surg
, vol.8
, pp. 94
-
-
Kazim, M.1
Katowitz, J.A.2
Fallon, M.3
-
12
-
-
84912993058
-
The use of inert plastic material in reconstructive surgery
-
J. Calnan The use of inert plastic material in reconstructive surgery Br J Plast Surg 16 1963 1
-
(1963)
Br J Plast Surg
, vol.16
, pp. 1
-
-
Calnan, J.1
-
14
-
-
0022460107
-
Late reaction to silicone following reconstruction of an orbital floor fracture
-
S.R. Sewall, F.G. Pernoud, M.J. Pernoud Late reaction to silicone following reconstruction of an orbital floor fracture J Oral Maxillofac Surg 44 1986 821
-
(1986)
J Oral Maxillofac Surg
, vol.44
, pp. 821
-
-
Sewall, S.R.1
Pernoud, F.G.2
Pernoud, M.J.3
-
15
-
-
0005510477
-
The latent period in carcinogenesis by plastics in rats and its relation to the presarcomatous stage
-
B.S. Oppenheimer, E.T. Oppenheimer, A.P. Stout The latent period in carcinogenesis by plastics in rats and its relation to the presarcomatous stage Cancer 11 1958 204
-
(1958)
Cancer
, vol.11
, pp. 204
-
-
Oppenheimer, B.S.1
Oppenheimer, E.T.2
Stout, A.P.3
-
16
-
-
0014244037
-
Some physical factors affecting the acceptance of synthetic materials as tissue implants
-
J.C. Davila, E.V. Lautsch, T.E. Palmer Some physical factors affecting the acceptance of synthetic materials as tissue implants Ann NY Acad Sci 146 1968 138
-
(1968)
Ann NY Acad Sci
, vol.146
, pp. 138
-
-
Davila, J.C.1
Lautsch, E.V.2
Palmer, T.E.3
-
17
-
-
85010247258
-
Prostheses and living tissues
-
J.C. Davila Prostheses and living tissues Ann Thorac Surg 2 1966 126
-
(1966)
Ann Thorac Surg
, vol.2
, pp. 126
-
-
Davila, J.C.1
-
18
-
-
0027163339
-
Use of medpor porous polyethylene implants in 140 patients with facial fractures
-
J.J. Romano, N.T. Iliff, P.N. Manson Use of medpor porous polyethylene implants in 140 patients with facial fractures J Craniofac Surg 4 1993 142
-
(1993)
J Craniofac Surg
, vol.4
, pp. 142
-
-
Romano, J.J.1
Iliff, N.T.2
Manson, P.N.3
-
20
-
-
0024556904
-
Complex orbital fractures: A critical analysis of immediate bone graft reconstruction
-
O. Antonyshyn, J.S. Gruss, D.J. Galbraith Complex orbital fractures A critical analysis of immediate bone graft reconstruction Plast Reconstr Surg 22 1989 220
-
(1989)
Plast Reconstr Surg
, vol.22
, pp. 220
-
-
Antonyshyn, O.1
Gruss, J.S.2
Galbraith, D.J.3
-
21
-
-
0014085020
-
Alloplastic materials in orbital repair
-
C. Browning Alloplastic materials in orbital repair Am J Ophthalmol 63 1967 955
-
(1967)
Am J Ophthalmol
, vol.63
, pp. 955
-
-
Browning, C.1
-
22
-
-
0022577010
-
Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligament sling and its relation to intramuscular cone orbital fat
-
P.N. Manson, C.M. Clifford, C.T. Su Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligament sling and its relation to intramuscular cone orbital fat Plast Reconstr Surg 77 1986 193
-
(1986)
Plast Reconstr Surg
, vol.77
, pp. 193
-
-
Manson, P.N.1
Clifford, C.M.2
Su, C.T.3
-
23
-
-
0019971723
-
Current concepts on the management of orbital blowout fractures
-
L. Koornneef Current concepts on the management of orbital blowout fractures Ann Plast Surg 9 1982 185
-
(1982)
Ann Plast Surg
, vol.9
, pp. 185
-
-
Koornneef, L.1
-
24
-
-
0023553023
-
Reconstruction of orbital wall fenestrations with polygalactin 910 film
-
W.D. Morain, E.D. Colby, M.E. Stauffer Reconstruction of orbital wall fenestrations with polygalactin 910 film Plast Reconstr Surg 80 1987 769
-
(1987)
Plast Reconstr Surg
, vol.80
, pp. 769
-
-
Morain, W.D.1
Colby, E.D.2
Stauffer, M.E.3
-
25
-
-
0023156863
-
The use of Teflon in orbital floor reconstruction following blunt facial trauma: A 20 year experience
-
J.W. Polley, S.L. Ringler The use of Teflon in orbital floor reconstruction following blunt facial trauma A 20 year experience Plast Reconstr Surg 79 1987 39
-
(1987)
Plast Reconstr Surg
, vol.79
, pp. 39
-
-
Polley, J.W.1
Ringler, S.L.2
-
26
-
-
0019970463
-
Use of auricular cartilage in orbital floor reconstruction
-
M.B. Constantian Use of auricular cartilage in orbital floor reconstruction Plast Reconstr Surg 69 1982 951
-
(1982)
Plast Reconstr Surg
, vol.69
, pp. 951
-
-
Constantian, M.B.1
-
27
-
-
0027263309
-
Late extrusion of alloplastic orbital floor implant
-
A.E. Brown, P. Banks Late extrusion of alloplastic orbital floor implant Br J Oral Maxillofac Surg 31 1993 154
-
(1993)
Br J Oral Maxillofac Surg
, vol.31
, pp. 154
-
-
Brown, A.E.1
Banks, P.2
-
28
-
-
0019466104
-
Correction of lower eyelid deformity caused by multiple extrusions of alloplastic orbital floor implants
-
S.A. Wolfe Correction of lower eyelid deformity caused by multiple extrusions of alloplastic orbital floor implants Plast Reconstr Surg 68 1981 429
-
(1981)
Plast Reconstr Surg
, vol.68
, pp. 429
-
-
Wolfe, S.A.1
-
29
-
-
4744345542
-
Late complication of orbital floor fracture with implant
-
J.A. Mauriello, P.M. Fiore, M. Kotch Late complication of orbital floor fracture with implant Ophthalmology 94 1987 2248
-
(1987)
Ophthalmology
, vol.94
, pp. 2248
-
-
Mauriello, J.A.1
Fiore, P.M.2
Kotch, M.3
-
30
-
-
0021331933
-
An unusual late complication of orbital floor fracture repair
-
J.A. Mauriello, J.C. Flanagan, R.G. Peyster An unusual late complication of orbital floor fracture repair Ophthalmology 91 1984 102
-
(1984)
Ophthalmology
, vol.91
, pp. 102
-
-
Mauriello, J.A.1
Flanagan, J.C.2
Peyster, R.G.3
-
32
-
-
0022998692
-
Cyanoacrylate tissue adhesive in securing orbital implants
-
D.T. Tse Cyanoacrylate tissue adhesive in securing orbital implants Ophthal Surg 17 1986 577
-
(1986)
Ophthal Surg
, vol.17
, pp. 577
-
-
Tse, D.T.1
-
33
-
-
0024439579
-
Cyanoacrylate fixed silicone sheet in medial blowout fracture repair
-
S.R. Seiff Cyanoacrylate fixed silicone sheet in medial blowout fracture repair Ophthal Surg 20 1989 674
-
(1989)
Ophthal Surg
, vol.20
, pp. 674
-
-
Seiff, S.R.1
-
34
-
-
0028308969
-
Lag screw technique for orbital floor reconstruction with autologous bone grafts
-
L.A. Assael, D.M. Feineramn Lag screw technique for orbital floor reconstruction with autologous bone grafts J Oral Maxillofac Surg 52 1994 646
-
(1994)
J Oral Maxillofac Surg
, vol.52
, pp. 646
-
-
Assael, L.A.1
Feineramn, D.M.2
-
35
-
-
0026595656
-
Advances in the management of orbital fractures
-
P.N. Nguyen, P. Sullivan Advances in the management of orbital fractures Clin Plast Surg 19 1992 87
-
(1992)
Clin Plast Surg
, vol.19
, pp. 87
-
-
Nguyen, P.N.1
Sullivan, P.2
-
36
-
-
0025900854
-
Reconstruction of internal orbital fractures with vitallium mesh
-
L.A. Sargent, D.K. Fulks Reconstruction of internal orbital fractures with vitallium mesh Plast Reconstr Surg 88 1991 31
-
(1991)
Plast Reconstr Surg
, vol.88
, pp. 31
-
-
Sargent, L.A.1
Fulks, D.K.2
-
37
-
-
0028116688
-
Orbital reconstruction using porous polyethylene sheets
-
P.A.D. Rubin, J.R. Bilyk, J.W. Shore Orbital reconstruction using porous polyethylene sheets Ophthalmology 101 1994 1697
-
(1994)
Ophthalmology
, vol.101
, pp. 1697
-
-
Rubin, P.A.D.1
Bilyk, J.R.2
Shore, J.W.3
-
38
-
-
0025141055
-
The effect of rigid fixation on the survival of onlay bone graft: An experimental study
-
K.Y. Lin, S.P. Bartlett, M.J. Yaremchuck The effect of rigid fixation on the survival of onlay bone graft An experimental study Plast Reconstr Surg 86 1990 449
-
(1990)
Plast Reconstr Surg
, vol.86
, pp. 449
-
-
Lin, K.Y.1
Bartlett, S.P.2
Yaremchuck, M.J.3
-
39
-
-
0016166324
-
Membranous bone versus endochondral bone autografts
-
J.D. Smith, M. Abramson Membranous bone versus endochondral bone autografts Arch Otolaryngol 99 1974 203
-
(1974)
Arch Otolaryngol
, vol.99
, pp. 203
-
-
Smith, J.D.1
Abramson, M.2
-
40
-
-
0021090605
-
Membranous versus endochondral bone: Implications for craniofacial reconstruction
-
J.E. Zins, L.A. Whitaker Membranous versus endochondral bone Implications for craniofacial reconstruction Plast Reconstr Surg 72 1983 778
-
(1983)
Plast Reconstr Surg
, vol.72
, pp. 778
-
-
Zins, J.E.1
Whitaker, L.A.2
-
42
-
-
0023794217
-
Fixation effects on membranous and endochondral onlay bone graft resorption
-
J.H. Phillip, B.A. Rahn Fixation effects on membranous and endochondral onlay bone graft resorption Plast Reconstr Surg 82 1988 872
-
(1988)
Plast Reconstr Surg
, vol.82
, pp. 872
-
-
Phillip, J.H.1
Rahn, B.A.2
-
44
-
-
0014858239
-
Experimental onlay bone grafts to the jaws. A preliminary study on dogs
-
N. Thompson, J.A. Casson Experimental onlay bone grafts to the jaws. A preliminary study on dogs Plast Reconstr Surg 46 1970 341
-
(1970)
Plast Reconstr Surg
, vol.46
, pp. 341
-
-
Thompson, N.1
Casson, J.A.2
-
45
-
-
0015968468
-
The influence of periosteum and calcitonin on onlay bone graft survival. A roentgenographic study
-
D.M. Knize The influence of periosteum and calcitonin on onlay bone graft survival. A roentgenographic study Plast Reconstr Surg 53 1974 190
-
(1974)
Plast Reconstr Surg
, vol.53
, pp. 190
-
-
Knize, D.M.1
-
46
-
-
0345698805
-
Volume maintenance of onlay bone grafts in the craniofacial skeleton: Micro-architecture versus embryologic origin
-
W. Ozaki, S.R. Buchman Volume maintenance of onlay bone grafts in the craniofacial skeleton Micro-architecture versus embryologic origin Plast Reconstr Surg 102 1998 291
-
(1998)
Plast Reconstr Surg
, vol.102
, pp. 291
-
-
Ozaki, W.1
Buchman, S.R.2
-
48
-
-
0027531575
-
Bone graft reconstruction of the monkey orbital floor with iliac grafts and titanium mesh plates: A histometric study
-
P.K. Sullivan, D.A. Rosenstein, R.E. Holmes Bone graft reconstruction of the monkey orbital floor with iliac grafts and titanium mesh plates A histometric study Plast Reconstr Surg 91 1993 760
-
(1993)
Plast Reconstr Surg
, vol.91
, pp. 760
-
-
Sullivan, P.K.1
Rosenstein, D.A.2
Holmes, R.E.3
-
50
-
-
0019514506
-
Experience with various procedures in the treatment of orbital floor fractures
-
R. Roncevic, B. Malinger Experience with various procedures in the treatment of orbital floor fractures J Oral Maxillofac Surg 9 1981 81
-
(1981)
J Oral Maxillofac Surg
, vol.9
, pp. 81
-
-
Roncevic, R.1
Malinger, B.2
-
51
-
-
0023316578
-
Reconstruction of orbital defects with autogenous bone from mandibular symphysis
-
M. Bagatin Reconstruction of orbital defects with autogenous bone from mandibular symphysis J Craniomaxillofac Surg 15 1987 103
-
(1987)
J Craniomaxillofac Surg
, vol.15
, pp. 103
-
-
Bagatin, M.1
-
52
-
-
0026575570
-
Orbital floor reconstruction with autogenous bone harvested from the mandibular lingual cortex
-
N.M. Girdler, M. Hosseini Orbital floor reconstruction with autogenous bone harvested from the mandibular lingual cortex Br J Oral Maxillofac Surg 30 1992 36
-
(1992)
Br J Oral Maxillofac Surg
, vol.30
, pp. 36
-
-
Girdler, N.M.1
Hosseini, M.2
-
53
-
-
0031696616
-
Contralateral coronoid process bone grafts for orbital floor reconstruction: An anatomic and clinical study
-
S.M. Mintz, A. Ettinger, T. Schmakel Contralateral coronoid process bone grafts for orbital floor reconstruction An anatomic and clinical study J Oral Maxillofac Surg 56 1998 1140
-
(1998)
J Oral Maxillofac Surg
, vol.56
, pp. 1140
-
-
Mintz, S.M.1
Ettinger, A.2
Schmakel, T.3
-
54
-
-
0030895947
-
Orbital floor reconstruction with autogenous mandibular symphyseal bone grafts
-
V. Krishnan, J.V. Johnson Orbital floor reconstruction with autogenous mandibular symphyseal bone grafts J Oral Maxillofac Surg 55 1997 327
-
(1997)
J Oral Maxillofac Surg
, vol.55
, pp. 327
-
-
Krishnan, V.1
Johnson, J.V.2
-
56
-
-
0242422684
-
The fate of living and dead cartilage transplanted in humans
-
L.A. Peer The fate of living and dead cartilage transplanted in humans Surg Gynecol Obstet 68 1939 603
-
(1939)
Surg Gynecol Obstet
, vol.68
, pp. 603
-
-
Peer, L.A.1
-
57
-
-
0001683077
-
Diced cartilage grafts
-
L.A. Peer Diced cartilage grafts Arch Otolaryngol 38 1943 156
-
(1943)
Arch Otolaryngol
, vol.38
, pp. 156
-
-
Peer, L.A.1
-
58
-
-
0242341787
-
Cartilage grafting
-
L.A. Peer Cartilage grafting Br J Plast Surg 7 1954 250
-
(1954)
Br J Plast Surg
, vol.7
, pp. 250
-
-
Peer, L.A.1
-
59
-
-
9844265676
-
Silicone fluid: Response to massive subcutaneous injections of dimethylpolysiloxane fluid in animals
-
D.L. Ballantyne, T.D. Rees, I. Seidman Silicone fluid Response to massive subcutaneous injections of dimethylpolysiloxane fluid in animals Plast Reconstr Surg 36 1965 330
-
(1965)
Plast Reconstr Surg
, vol.36
, pp. 330
-
-
Ballantyne, D.L.1
Rees, T.D.2
Seidman, I.3
-
60
-
-
85046499005
-
Not seeing eye to eye about septal grafts for orbital fractures
-
J.R. Werther Not seeing eye to eye about septal grafts for orbital fractures [letter] J Oral Maxillofac Surg 56 1998 906
-
(1998)
J Oral Maxillofac Surg
, vol.56
, pp. 906
-
-
Werther, J.R.1
-
61
-
-
0026517851
-
Experience in the use of calvarial bone grafts in orbital reconstruction
-
V. Ilankovan, I.T. Jackson Experience in the use of calvarial bone grafts in orbital reconstruction Br J Oral Maxillofac Surg 30 1992 92
-
(1992)
Br J Oral Maxillofac Surg
, vol.30
, pp. 92
-
-
Ilankovan, V.1
Jackson, I.T.2
-
62
-
-
0001889104
-
Reconstruction of the floor of the orbit by bone grafts
-
J.M. Converse, B. Smith Reconstruction of the floor of the orbit by bone grafts Arch Ophthalmol 44 1950 1
-
(1950)
Arch Ophthalmol
, vol.44
, pp. 1
-
-
Converse, J.M.1
Smith, B.2
-
63
-
-
0024556904
-
Complex Orbital fractures: A critical analysis of immediate bone graft reconstruction
-
O. Antonyshyn, J.S. Gruss, D.J. Galbraith Complex Orbital fractures A critical analysis of immediate bone graft reconstruction Ann Plast Surg 22 1989 220
-
(1989)
Ann Plast Surg
, vol.22
, pp. 220
-
-
Antonyshyn, O.1
Gruss, J.S.2
Galbraith, D.J.3
-
64
-
-
0031923249
-
Repair of orbital blow-out fractures with nasoseptal cartilage
-
A. Lai, R.E. Gliklick, P.A.D. Rubin Repair of orbital blow-out fractures with nasoseptal cartilage Laryngoscope 108 1998 645
-
(1998)
Laryngoscope
, vol.108
, pp. 645
-
-
Lai, A.1
Gliklick, R.E.2
Rubin, P.A.D.3
-
66
-
-
0030981721
-
Repair of traumatic orbital wall defects with nasal septal cartilage: Report of 5 cases
-
K.K. Li Repair of traumatic orbital wall defects with nasal septal cartilage Report of 5 cases J Oral Maxillofac Surg 55 1997 1098
-
(1997)
J Oral Maxillofac Surg
, vol.55
, pp. 1098
-
-
Li, K.K.1
-
68
-
-
0023666125
-
Rapidly progressive dementia in a patient who received a cadaveric dura mater graft
-
J. Prichard, V. Thadani, R. Kalb Rapidly progressive dementia in a patient who received a cadaveric dura mater graft JAMA 257 1987 1036
-
(1987)
JAMA
, vol.257
, pp. 1036
-
-
Prichard, J.1
Thadani, V.2
Kalb, R.3
-
70
-
-
0026731570
-
Early surgical intervention for orbital floor fractures: A clinical evaluation of lyophilized dura and cartilage reconstruction
-
J.M. Chen, M. Zingg, K. Laedrach Early surgical intervention for orbital floor fractures A clinical evaluation of lyophilized dura and cartilage reconstruction J Oral Maxillofac Surg 50 1992 935
-
(1992)
J Oral Maxillofac Surg
, vol.50
, pp. 935
-
-
Chen, J.M.1
Zingg, M.2
Laedrach, K.3
-
71
-
-
0031051591
-
Reconstruction of the orbital floor with lyophilized tensor fascia lata
-
B. Celikoz, H. Duman, N. Selmanpakoglu Reconstruction of the orbital floor with lyophilized tensor fascia lata J Oral Maxillofac Surg 55 1998 240
-
(1998)
J Oral Maxillofac Surg
, vol.55
, pp. 240
-
-
Celikoz, B.1
Duman, H.2
Selmanpakoglu, N.3
-
72
-
-
0027453183
-
Banked fascia lata as an orbital floor implant
-
E.H. Bedrossian Banked fascia lata as an orbital floor implant Ophthal Plast Reconstr Surg 9 1993 66
-
(1993)
Ophthal Plast Reconstr Surg
, vol.9
, pp. 66
-
-
Bedrossian, E.H.1
-
74
-
-
0027360533
-
Use of homologous bone in maxillofacial surgery
-
E. Ellis, D.P. Sinn Use of homologous bone in maxillofacial surgery J Oral Maxillofac Surg 51 1993 1181
-
(1993)
J Oral Maxillofac Surg
, vol.51
, pp. 1181
-
-
Ellis, E.1
Sinn, D.P.2
-
75
-
-
0026731570
-
Early surgical intervention for orbital floor fractures. A clinical evaluation of lyophilized dura and cartilage reconstruction
-
J.M. Chen, M. Zingg, K. Laedrach Early surgical intervention for orbital floor fractures. A clinical evaluation of lyophilized dura and cartilage reconstruction J Oral Maxillofac Surg 50 1992 935
-
(1992)
J Oral Maxillofac Surg
, vol.50
, pp. 935
-
-
Chen, J.M.1
Zingg, M.2
Laedrach, K.3
-
76
-
-
0023874701
-
Orbital floor repair with lyophilized porcine dermis
-
K. Webster Orbital floor repair with lyophilized porcine dermis Oral Surg Oral Med Oral Pathol 65 1988 161
-
(1988)
Oral Surg Oral Med Oral Pathol
, vol.65
, pp. 161
-
-
Webster, K.1
-
77
-
-
0026581714
-
Complex orbital fracture repair using rigid fixation of the internal orbital skeleton
-
P.A.D. Rubin, J.W. Shore, M.J. Yaremchuck Complex orbital fracture repair using rigid fixation of the internal orbital skeleton Ophthalmology 99 1992 553
-
(1992)
Ophthalmology
, vol.99
, pp. 553
-
-
Rubin, P.A.D.1
Shore, J.W.2
Yaremchuck, M.J.3
-
79
-
-
0028158531
-
The natural history of alloplastic implants in orbital floor reconstruction: An animal model
-
W.R. Dougherty, T. Wellisz The natural history of alloplastic implants in orbital floor reconstruction An animal model J Craniofac Surg 5 1994 26
-
(1994)
J Craniofac Surg
, vol.5
, pp. 26
-
-
Dougherty, W.R.1
Wellisz, T.2
-
80
-
-
0029886923
-
Correction of late enophthalmos with polyethylene implants
-
J.W. Karesh, B.B. Horswell Correction of late enophthalmos with polyethylene implants J Craniomaxillfac Trauma 2 1996 18
-
(1996)
J Craniomaxillfac Trauma
, vol.2
, pp. 18
-
-
Karesh, J.W.1
Horswell, B.B.2
-
81
-
-
0023932807
-
Porous hydroxyapatite as a bone graft substitute in cranial reconstruction: A histometric study
-
R. Holmes, H. Hagler Porous hydroxyapatite as a bone graft substitute in cranial reconstruction A histometric study Plast Reconstr Surg 81 1988 662
-
(1988)
Plast Reconstr Surg
, vol.81
, pp. 662
-
-
Holmes, R.1
Hagler, H.2
-
82
-
-
0025222340
-
Use of blocks of hydroxylapatite for secondary reconstruction of the orbital floor
-
J. Hes, K. de Man Use of blocks of hydroxylapatite for secondary reconstruction of the orbital floor Int J Oral Maxillofac Surg 19 1990 275
-
(1990)
Int J Oral Maxillofac Surg
, vol.19
, pp. 275
-
-
Hes, J.1
De Man, K.2
-
83
-
-
0023949140
-
Correction of vertical orbital dystopia with a hydroxylapatite orbital floor graft
-
M.S. Block, J.N. Kent Correction of vertical orbital dystopia with a hydroxylapatite orbital floor graft J Oral Maxillofac Surg 46 1988 420
-
(1988)
J Oral Maxillofac Surg
, vol.46
, pp. 420
-
-
Block, M.S.1
Kent, J.N.2
-
84
-
-
0022536932
-
Late posttraumatic enophthalmus corrected by dense hydroxylapatite blocks
-
M.F. Zide Late posttraumatic enophthalmus corrected by dense hydroxylapatite blocks J Oral Maxillofac Surg 44 1986 804
-
(1986)
J Oral Maxillofac Surg
, vol.44
, pp. 804
-
-
Zide, M.F.1
-
86
-
-
0014492911
-
Orbital floor Implants
-
J. Gamble Orbital floor Implants Arch Otolaryngol 89 1969 596
-
(1969)
Arch Otolaryngol
, vol.89
, pp. 596
-
-
Gamble, J.1
-
87
-
-
84937174164
-
Further observations on the use of silicones in the management of orbital fractures
-
H. Lipshutz, R.A. Ardizone Further observations on the use of silicones in the management of orbital fractures J Trauma 5 1965 617
-
(1965)
J Trauma
, vol.5
, pp. 617
-
-
Lipshutz, H.1
Ardizone, R.A.2
-
88
-
-
0018407146
-
Correction of persistent lower eyelid deformity caused by displaced orbital floor implant
-
S.A. Wolfe Correction of persistent lower eyelid deformity caused by displaced orbital floor implant Ann Plast Surg 2 1979 448
-
(1979)
Ann Plast Surg
, vol.2
, pp. 448
-
-
Wolfe, S.A.1
-
90
-
-
0026782370
-
Complications associated with alloplastic implants used in orbital fracture repair
-
D.R. Jordan, P. St Onge, R.L. Anderson Complications associated with alloplastic implants used in orbital fracture repair Ophthalmology 99 1992 1600
-
(1992)
Ophthalmology
, vol.99
, pp. 1600
-
-
Jordan, D.R.1
St Onge, P.2
Anderson, R.L.3
-
92
-
-
0028898019
-
The use of silastic as an orbital implant for reconstructions of orbital wall defects: A review of 311 cases treated over 20 years
-
A.d. Morrison, R.C. Sanderson, K.F. Moos The use of silastic as an orbital implant for reconstructions of orbital wall defects A review of 311 cases treated over 20 years J Oral Maxillofac Surg 53 1995 412
-
(1995)
J Oral Maxillofac Surg
, vol.53
, pp. 412
-
-
Morrison, A.D.1
Sanderson, R.C.2
Moos, K.F.3
-
93
-
-
0028326479
-
Hemorrhagic cyst of the orbit as a long term complication of prosthetic orbital floor implants
-
M.W. Marks, R.P. Yeatts Hemorrhagic cyst of the orbit as a long term complication of prosthetic orbital floor implants Plast Reconstr Surg 93 1994 856
-
(1994)
Plast Reconstr Surg
, vol.93
, pp. 856
-
-
Marks, M.W.1
Yeatts, R.P.2
-
94
-
-
0024833598
-
Bioabsorbable plates and screws for internal fixation of mandibular fractures. A study in six dogs
-
R.R.M. Bos, F.R. Rozema, G. Boering Bioabsorbable plates and screws for internal fixation of mandibular fractures. A study in six dogs Int J Oral Maxillofac Surg 18 1989 365
-
(1989)
Int J Oral Maxillofac Surg
, vol.18
, pp. 365
-
-
Bos, R.R.M.1
Rozema, F.R.2
Boering, G.3
-
95
-
-
0023205611
-
Resorbable poly(L-lactide) plates and screws for the fixation of unstable zygomatic fractures
-
R.R.M. Bos, F.R. Rozema, G. Boering Resorbable poly(L-lactide) plates and screws for the fixation of unstable zygomatic fractures J Oral Maxillofac Surg 45 1987 751
-
(1987)
J Oral Maxillofac Surg
, vol.45
, pp. 751
-
-
Bos, R.R.M.1
Rozema, F.R.2
Boering, G.3
-
96
-
-
0027308691
-
Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures
-
E.J. Bergsma, F.R. Rozema, R.R.M. Bos Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures J Oral Maxillofac Surg 51 1993 666
-
(1993)
J Oral Maxillofac Surg
, vol.51
, pp. 666
-
-
Bergsma, E.J.1
Rozema, F.R.2
Bos, R.R.M.3
-
97
-
-
0025245617
-
Poly(L-lactide) implants in repair of defects of the orbital floor: An animal study
-
F.R. Rozema, R.R.M. Bos, A.J. Pennings Poly(L-lactide) implants in repair of defects of the orbital floor An animal study J Oral Maxillofac Surg 48 1990 1305
-
(1990)
J Oral Maxillofac Surg
, vol.48
, pp. 1305
-
-
Rozema, F.R.1
Bos, R.R.M.2
Pennings, A.J.3
-
98
-
-
0028878553
-
Late degradation tissue response to poly(l-lactide) bone plates and screws
-
E.J. Bergsma, W.C. de Bruijn, F.R. Rozema Late degradation tissue response to poly(l-lactide) bone plates and screws Biomaterials 16 1995 25
-
(1995)
Biomaterials
, vol.16
, pp. 25
-
-
Bergsma, E.J.1
De Bruijn, W.C.2
Rozema, F.R.3
-
99
-
-
0030038462
-
Poly(L-lactide) implants for repair of human orbital floor defects: Clinical and MRI evaluation of long term results
-
F.W. Cordewener, R.R.M. Bos, F.R. Rozema Poly(L-lactide) implants for repair of human orbital floor defects Clinical and MRI evaluation of long term results J Oral Maxillofac Surg 54 1996 9
-
(1996)
J Oral Maxillofac Surg
, vol.54
, pp. 9
-
-
Cordewener, F.W.1
Bos, R.R.M.2
Rozema, F.R.3
-
101
-
-
0343581266
-
Craniofacial skeletal fixation using biodegradable plates and cyanoacrylate glue
-
D.K. Ahu, C.D. Sims, M.A. Randolph Craniofacial skeletal fixation using biodegradable plates and cyanoacrylate glue Plast Reconstr Surg 99 1997 1508
-
(1997)
Plast Reconstr Surg
, vol.99
, pp. 1508
-
-
Ahu, D.K.1
Sims, C.D.2
Randolph, M.A.3
-
103
-
-
4744339446
-
Wiederherstellung von orbitabodendefektn mit Polyglactin
-
W. Holtje Wiederherstellung von orbitabodendefektn mit Polyglactin Fortschr Kieber Gesichtschir 28 1983 65
-
(1983)
Fortschr Kieber Gesichtschir
, vol.28
, pp. 65
-
-
Holtje, W.1
-
104
-
-
0027249468
-
Use of Vicryl (Polyglactin 910) mesh implant for repair of orbital floor fracture causing diplopia: A study of 28 patients over 5 years
-
J.A. Mauriello, B. Wasserman, R. Krant Use of Vicryl (Polyglactin 910) mesh implant for repair of orbital floor fracture causing diplopia A study of 28 patients over 5 years Ophthal Plast Reconstr Surg 9 1993 191
-
(1993)
Ophthal Plast Reconstr Surg
, vol.9
, pp. 191
-
-
Mauriello, J.A.1
Wasserman, B.2
Krant, R.3
-
106
-
-
0027308705
-
Suitability of biodegradable polydioxanone materials for the internal fixation of fractures
-
P.J. Papgelopoulos, D.G. Giannarakaos, G.P. Lyritis Suitability of biodegradable polydioxanone materials for the internal fixation of fractures Orthop Rev 22 1993 585
-
(1993)
Orthop Rev
, vol.22
, pp. 585
-
-
Papgelopoulos, P.J.1
Giannarakaos, D.G.2
Lyritis, G.P.3
-
107
-
-
0035221558
-
Reconstruction of critical size orbital defects in sheep using biodegradable implants-12 Months follow-up and conclusions for future clinical use in humans
-
R. de Roche, A. Kuhn, N. Adolphs Reconstruction of critical size orbital defects in sheep using biodegradable implants-12 Months follow-up and conclusions for future clinical use in humans Mund Kiefer Gesichtschir 5 2001 49
-
(2001)
Mund Kiefer Gesichtschir
, vol.5
, pp. 49
-
-
De Roche, R.1
Kuhn, A.2
Adolphs, N.3
-
108
-
-
0035199515
-
Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant
-
R. Kontio, R. Suuronen, O. Salonen Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant Int J Oral Maxillofac Surg 30 2001 278
-
(2001)
Int J Oral Maxillofac Surg
, vol.30
, pp. 278
-
-
Kontio, R.1
Suuronen, R.2
Salonen, O.3
-
109
-
-
0029419226
-
Repair of orbital floor fractures with absorbable gelatin film
-
R.W. Mermer, R.E. Orban Repair of orbital floor fractures with absorbable gelatin film J Craniomaxillofac Trauma 1 1995 30
-
(1995)
J Craniomaxillofac Trauma
, vol.1
, pp. 30
-
-
Mermer, R.W.1
Orban, R.E.2
-
110
-
-
0017601078
-
Experimental repair of orbital floor fracture
-
S.R. Levinson, R.F. Canalis Experimental repair of orbital floor fracture Arch Otolaryngol 103 1977 188
-
(1977)
Arch Otolaryngol
, vol.103
, pp. 188
-
-
Levinson, S.R.1
Canalis, R.F.2
-
111
-
-
0033186478
-
Symposium: Biomaterial in the face: Benefits and risks
-
A.K. Gosain, J.A. Persing Symposium: Biomaterial in the face: Benefits and risks J Craniofac Surg 10 1999 404
-
(1999)
J Craniofac Surg
, vol.10
, pp. 404
-
-
Gosain, A.K.1
Persing, J.A.2
|