메뉴 건너뛰기




Volumn 25, Issue 2, 2010, Pages 203-207

Hylamer vs Conventional Polyethylene in Primary Total Hip Arthroplasty: A Long-Term Case-Control Study of Wear Rates and Osteolysis

Author keywords

hylamer; osteolysis; polyethylene wear

Indexed keywords

POLYETHYLENE;

EID: 74249115141     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2009.02.006     Document Type: Article
Times cited : (20)

References (19)
  • 2
    • 0000642709 scopus 로고    scopus 로고
    • The effect of crystallinity on the physical properties of UHMWPE
    • Champion A.R., Li S., Saum K., et al. The effect of crystallinity on the physical properties of UHMWPE. Trans 40th Orthop Res Soc 19 (1999) 585
    • (1999) Trans 40th Orthop Res Soc , vol.19 , pp. 585
    • Champion, A.R.1    Li, S.2    Saum, K.3
  • 3
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz S.M., Muratoglu O.K., Evans M., et al. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 20 (1999) 1659
    • (1999) Biomaterials , vol.20 , pp. 1659
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3
  • 4
    • 0028129938 scopus 로고
    • Ultra-high molecular weight polyethylene. The material and its use in total joint implants
    • Li S., and Burstein A.H. Ultra-high molecular weight polyethylene. The material and its use in total joint implants. J Bone Joint Surg Am 76 (1994) 1080
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1080
    • Li, S.1    Burstein, A.H.2
  • 5
    • 0031855324 scopus 로고    scopus 로고
    • Examination of wear in Duraloc acetabular components: two- to five-year evaluation of Hylamer and Enduron liners
    • Sychterz C.J., Shah N., and Engh C.A. Examination of wear in Duraloc acetabular components: two- to five-year evaluation of Hylamer and Enduron liners. J Arthroplasty 13 (1998) 508
    • (1998) J Arthroplasty , vol.13 , pp. 508
    • Sychterz, C.J.1    Shah, N.2    Engh, C.A.3
  • 6
    • 0036054774 scopus 로고    scopus 로고
    • Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    • Young A.M., Sychterz C.J., Hopper Jr. R.H., et al. Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84-A (2002) 58
    • (2002) J Bone Joint Surg Am , vol.84 -A , pp. 58
    • Young, A.M.1    Sychterz, C.J.2    Hopper Jr., R.H.3
  • 7
    • 0029989624 scopus 로고    scopus 로고
    • Early failure of Hylamer acetabular inserts due to eccentric wear
    • Chmell M.J., Poss R., Thomas W.H., et al. Early failure of Hylamer acetabular inserts due to eccentric wear. J Arthroplasty 11 (1996) 351
    • (1996) J Arthroplasty , vol.11 , pp. 351
    • Chmell, M.J.1    Poss, R.2    Thomas, W.H.3
  • 8
    • 7344222590 scopus 로고    scopus 로고
    • An analysis of Hylamer and polyethylene bearings from retrieved acetabular components
    • Collier J.P., Bargmann L.S., Currier B.H., et al. An analysis of Hylamer and polyethylene bearings from retrieved acetabular components. Orthopedics 21 (1998) 865
    • (1998) Orthopedics , vol.21 , pp. 865
    • Collier, J.P.1    Bargmann, L.S.2    Currier, B.H.3
  • 9
    • 0030225849 scopus 로고    scopus 로고
    • Early failure of Hylamer acetabular inserts due to eccentric wear
    • Ezzet K.A. Early failure of Hylamer acetabular inserts due to eccentric wear. J Arthroplasty 11 (1996) 761
    • (1996) J Arthroplasty , vol.11 , pp. 761
    • Ezzet, K.A.1
  • 10
    • 0031811155 scopus 로고    scopus 로고
    • Early osteolysis with Hylamer acetabular liners
    • Graeter J.H., and Nevins R. Early osteolysis with Hylamer acetabular liners. J Arthroplasty 13 (1998) 464
    • (1998) J Arthroplasty , vol.13 , pp. 464
    • Graeter, J.H.1    Nevins, R.2
  • 11
    • 0030726816 scopus 로고    scopus 로고
    • Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner
    • Livingston B.J., Chmell M.J., Spector M., et al. Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner. J Bone Joint Surg Am 79 (1997) 1529
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1529
    • Livingston, B.J.1    Chmell, M.J.2    Spector, M.3
  • 12
    • 0034987572 scopus 로고    scopus 로고
    • Head penetration into Hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere
    • Yamauchi K., Hasegawa Y., Iwasada S., et al. Head penetration into Hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere. J Arthroplasty 16 (2001) 463
    • (2001) J Arthroplasty , vol.16 , pp. 463
    • Yamauchi, K.1    Hasegawa, Y.2    Iwasada, S.3
  • 13
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J., Ilstrup D., and Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72 (1990) 518
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 14
    • 0041633552 scopus 로고    scopus 로고
    • Radiographic definition of pelvic osteolysis following total hip arthroplasty
    • Claus A.M., Engh Jr. C.A., Sychterz C.J., et al. Radiographic definition of pelvic osteolysis following total hip arthroplasty. J Bone Joint Surg Am 85-A (2003) 1519
    • (2003) J Bone Joint Surg Am , vol.85 -A , pp. 1519
    • Claus, A.M.1    Engh Jr., C.A.2    Sychterz, C.J.3
  • 15
    • 33845434178 scopus 로고    scopus 로고
    • The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis
    • Kitamura N., Pappedemos P.C., Duffy III P.R., et al. The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis. Clin Orthop Relat Res 453 (2006) 239
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 239
    • Kitamura, N.1    Pappedemos, P.C.2    Duffy III, P.R.3
  • 16
    • 2442608349 scopus 로고    scopus 로고
    • Sterilization and polyethylene wear: clinical studies to support laboratory data
    • Sychterz C.J., Orishimo K.F., and Engh C.A. Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am 86-A (2004) 1017
    • (2004) J Bone Joint Surg Am , vol.86 -A , pp. 1017
    • Sychterz, C.J.1    Orishimo, K.F.2    Engh, C.A.3
  • 17
    • 0034030993 scopus 로고    scopus 로고
    • Comparison of head penetration into Hylamer and Enduro polyethylene liners: a follow-up report
    • Sychterz C.J., Young A.M., McAuley J.P., et al. Comparison of head penetration into Hylamer and Enduro polyethylene liners: a follow-up report. J Arthroplasty 15 (2000) 372
    • (2000) J Arthroplasty , vol.15 , pp. 372
    • Sychterz, C.J.1    Young, A.M.2    McAuley, J.P.3
  • 18
    • 27144440206 scopus 로고    scopus 로고
    • Isolation and characterization of wear debris generated in patients wearing polyethylene Hylamer inserts, gamma irradiated in air
    • Visentin M., Stea S., Squarzoni S., et al. Isolation and characterization of wear debris generated in patients wearing polyethylene Hylamer inserts, gamma irradiated in air. J Biomater Appl 20 (2005) 103
    • (2005) J Biomater Appl , vol.20 , pp. 103
    • Visentin, M.1    Stea, S.2    Squarzoni, S.3
  • 19
    • 0029125716 scopus 로고
    • Wear of the polyethylene of Harris-Galante acetabular components inserted without cement
    • Woolson S.T., and Murphy M.G. Wear of the polyethylene of Harris-Galante acetabular components inserted without cement. J Bone and Joint Surg 77A (1995) 1311
    • (1995) J Bone and Joint Surg , vol.77 A , pp. 1311
    • Woolson, S.T.1    Murphy, M.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.