-
1
-
-
0031708749
-
Advances in nuclear medicine instrumentation: considerations in the design and selection of an imaging system
-
Links J.M. Advances in nuclear medicine instrumentation: considerations in the design and selection of an imaging system. Eur. J. Nucl. Med. 25 (1998) 1453-1466
-
(1998)
Eur. J. Nucl. Med.
, vol.25
, pp. 1453-1466
-
-
Links, J.M.1
-
2
-
-
0021261066
-
Analysis of emission tomographic scan data: limitations imposed by resolution and background
-
Kessler R.M., Ellis Jr. J.R., and Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J. Comput. Assist. Tomogr. 8 (1984) 514-522
-
(1984)
J. Comput. Assist. Tomogr.
, vol.8
, pp. 514-522
-
-
Kessler, R.M.1
Ellis Jr., J.R.2
Eden, M.3
-
3
-
-
0019357118
-
Quantitation in positron emission computed-tomography: 5. physical-anatomical effects
-
Mazziotta J.C., Phelps M.E., Plummer D., and Kuhl D.E. Quantitation in positron emission computed-tomography: 5. physical-anatomical effects. J. Comput. Assist. Tomogr. 5 (1981) 734-743
-
(1981)
J. Comput. Assist. Tomogr.
, vol.5
, pp. 734-743
-
-
Mazziotta, J.C.1
Phelps, M.E.2
Plummer, D.3
Kuhl, D.E.4
-
4
-
-
0018367149
-
Quantitation in positron emission computed tomography: 1. effect of object size
-
Hoffman E.J., Huang S.C., and Phelps M.E. Quantitation in positron emission computed tomography: 1. effect of object size. J. Comput. Assist. Tomogr. 3 (1979) 299-308
-
(1979)
J. Comput. Assist. Tomogr.
, vol.3
, pp. 299-308
-
-
Hoffman, E.J.1
Huang, S.C.2
Phelps, M.E.3
-
5
-
-
0032920128
-
Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data
-
Chen C.H. Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data. J. Nucl. Med. 40 (1999) 118-130
-
(1999)
J. Nucl. Med.
, vol.40
, pp. 118-130
-
-
Chen, C.H.1
-
6
-
-
0031955835
-
Correction for partial volume effects in PET: principle and validation
-
Rousset O.G. Correction for partial volume effects in PET: principle and validation. J. Nucl. Med. 39 (1998) 904-911
-
(1998)
J. Nucl. Med.
, vol.39
, pp. 904-911
-
-
Rousset, O.G.1
-
7
-
-
0025123951
-
Design and use of PET tomographs: the effect of slice spacing
-
Miller T.R. Design and use of PET tomographs: the effect of slice spacing. J. Nucl. Med. 31 (1990) 1732-1739
-
(1990)
J. Nucl. Med.
, vol.31
, pp. 1732-1739
-
-
Miller, T.R.1
-
8
-
-
9844227354
-
Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers Association
-
Brix G., Zaers J., Adam L.E., Bellemann M.E., Ostertag H., Trojan H., Haberkorn U., Doll J., Oberdorfer F., and Lorenz W.J. Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers Association. J. Nucl. Med. 38 (1997) 1614-1623
-
(1997)
J. Nucl. Med.
, vol.38
, pp. 1614-1623
-
-
Brix, G.1
Zaers, J.2
Adam, L.E.3
Bellemann, M.E.4
Ostertag, H.5
Trojan, H.6
Haberkorn, U.7
Doll, J.8
Oberdorfer, F.9
Lorenz, W.J.10
-
9
-
-
0026323156
-
Performance standards in positron emission tomography
-
Karp J.S., Daube-Witherspoon M.E., Hoffman E.J., Lewellen T.K., Links J.M., Wong W.H., Hichwa R.D., Casey M.E., Colsher J.G., and Hitchens R.E. Performance standards in positron emission tomography. J. Nucl. Med. 32 (1991) 2342-2350
-
(1991)
J. Nucl. Med.
, vol.32
, pp. 2342-2350
-
-
Karp, J.S.1
Daube-Witherspoon, M.E.2
Hoffman, E.J.3
Lewellen, T.K.4
Links, J.M.5
Wong, W.H.6
Hichwa, R.D.7
Casey, M.E.8
Colsher, J.G.9
Hitchens, R.E.10
-
11
-
-
34748826802
-
Partial volume effect-corrected FDG PET and grey matter volume loss in patients with mild Alzheimer's disease
-
Samuraki M., Matsunari I., Chen W., Yajima K., Yanase D., Fujikawa A., Takeda N., Nishimura S., Matsuda H., and Yamada M. Partial volume effect-corrected FDG PET and grey matter volume loss in patients with mild Alzheimer's disease. Eur. J. Nucl. Med. 34 (2007) 1658-1669
-
(2007)
Eur. J. Nucl. Med.
, vol.34
, pp. 1658-1669
-
-
Samuraki, M.1
Matsunari, I.2
Chen, W.3
Yajima, K.4
Yanase, D.5
Fujikawa, A.6
Takeda, N.7
Nishimura, S.8
Matsuda, H.9
Yamada, M.10
-
13
-
-
0037945455
-
PET instrumentation and reconstruction algorithms in whole-body applications
-
Tarantola G., Zito F., and Gerundini P. PET instrumentation and reconstruction algorithms in whole-body applications. J. Nucl. Med. 44 (2003) 756-769
-
(2003)
J. Nucl. Med.
, vol.44
, pp. 756-769
-
-
Tarantola, G.1
Zito, F.2
Gerundini, P.3
-
14
-
-
17844363989
-
Performance evaluation of the microPET focus: a third-generation microPET scanner dedicated to animal imaging
-
Tai Y.C., Ruangma A., Rowland D., Siegel S., Newport D.F., Chow P.L., and Laforest R. Performance evaluation of the microPET focus: a third-generation microPET scanner dedicated to animal imaging. J. Nucl. Med. 46 (2005) 455-463
-
(2005)
J. Nucl. Med.
, vol.46
, pp. 455-463
-
-
Tai, Y.C.1
Ruangma, A.2
Rowland, D.3
Siegel, S.4
Newport, D.F.5
Chow, P.L.6
Laforest, R.7
-
16
-
-
0026700928
-
Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects
-
Muller-Gartner H.W., Links J.M., Prince J.L., Bryan R.N., McVeigh E., Leal J.P., Davatzikos C., and Frost J.J. Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects. J. Cereb. Blood Flow Metab. 12 (1992) 571-583
-
(1992)
J. Cereb. Blood Flow Metab.
, vol.12
, pp. 571-583
-
-
Muller-Gartner, H.W.1
Links, J.M.2
Prince, J.L.3
Bryan, R.N.4
McVeigh, E.5
Leal, J.P.6
Davatzikos, C.7
Frost, J.J.8
|