메뉴 건너뛰기




Volumn 125, Issue 1, 2010, Pages

The effect of averaging time on oximetry values in the premature infant

Author keywords

Averaging time; Desaturation; Neonates; Oxygen saturation; Prematurity; Pulse oximeters; Retinopathy of prematurity

Indexed keywords

ARTICLE; ASSISTED VENTILATION; CLINICAL ARTICLE; CLINICAL EVALUATION; COMPARATIVE STUDY; DISEASE SEVERITY; GESTATIONAL AGE; HUMAN; NERVE CELL DIFFERENTIATION; NEWBORN; OUTCOME ASSESSMENT; OXYGEN SATURATION; PILOT STUDY; PREMATURITY; PRIORITY JOURNAL; PULSE OXIMETRY; TIME;

EID: 74049163792     PISSN: 00314005     EISSN: 10984275     Source Type: Journal    
DOI: 10.1542/peds.2008-1749     Document Type: Article
Times cited : (47)

References (15)
  • 1
    • 0037312997 scopus 로고    scopus 로고
    • Can changes in clinical practice decrease the incidence of severe retinopathy of prematurity in very low birth weight infants?
    • Chow LC, Wright KW, Sola A. Can changes in clinical practice decrease the incidence of severe retinopathy of prematurity in very low birth weight infants? Pediatrics. 2003;111(2):339-345
    • (2003) Pediatrics , vol.111 , Issue.2 , pp. 339-345
    • Chow, L.C.1    Wright, K.W.2    Sola, A.3
  • 2
    • 0035079857 scopus 로고    scopus 로고
    • Pulse oximetry, severe retinopathy, and outcome at one year in babies of less than 28 weeks' gestation
    • Tin W, Milligan DWA, Pennefather P, Hey E. Pulse oximetry, severe retinopathy, and outcome at one year in babies of less than 28 weeks' gestation. Arch Dis Child Fetal Neonatal Ed. 2001;84(2):F106-F110
    • (2001) Arch Dis Child Fetal Neonatal Ed , vol.84 , Issue.2
    • Tin, W.1    Milligan, D.W.A.2    Pennefather, P.3    Hey, E.4
  • 3
    • 33744526222 scopus 로고    scopus 로고
    • Pulse oximetry in very low birth weight infants: Can oxygen saturation be maintained in the desired range?
    • Laptook AR, Salhab W, Saha S, Walsh M. Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range? J Perinatol. 2006;26:337-341
    • (2006) J Perinatol , vol.26 , pp. 337-341
    • Laptook, A.R.1    Salhab, W.2    Saha, S.3    Walsh, M.4
  • 4
    • 5144230047 scopus 로고    scopus 로고
    • Cardiorespiratory events detected by home memory monitoring and one year neurodevelopmental outcome
    • Hunt CE, Corwin MJ, Baird T, et al. Cardiorespiratory events detected by home memory monitoring and one year neurodevelopmental outcome. J Pediatr. 2004;145(4):465-471
    • (2004) J Pediatr , vol.145 , Issue.4 , pp. 465-471
    • Hunt, C.E.1    Corwin, M.J.2    Baird, T.3
  • 6
    • 0033051353 scopus 로고    scopus 로고
    • Pulse oximetry
    • Jubran A. Pulse oximetry. Crit Care. 1999;3(2):R11-R17
    • (1999) Crit Care , vol.3 , Issue.2
    • Jubran, A.1
  • 8
    • 26844433878 scopus 로고    scopus 로고
    • Clinical use of new generation pulse oximeters in the neonatal intensive care unit
    • Workie FA, Rais-Bahrami K, Short BL. Clinical use of new generation pulse oximeters in the neonatal intensive care unit. Am J Perinatol. 2005;22(7):357-360
    • (2005) Am J Perinatol , vol.22 , Issue.7 , pp. 357-360
    • Workie, F.A.1    Rais-Bahrami, K.2    Short, B.L.3
  • 9
    • 0034304541 scopus 로고    scopus 로고
    • Next-generation pulse oximetry: Focusing on Masimo's signal extraction technology
    • Next-generation pulse oximetry: focusing on Masimo's signal extraction technology. Health Devices. 2000;29(10):349-370
    • (2000) Health Devices , vol.29 , Issue.10 , pp. 349-370
  • 11
    • 1242293015 scopus 로고    scopus 로고
    • Appropriate levels of oxygen saturation for preterm infants
    • Askie L. Appropriate levels of oxygen saturation for preterm infants. Acta Paedtr Suppl. 2004;93(444):26-28
    • (2004) Acta Paedtr Suppl , vol.93 , Issue.444 , pp. 26-28
    • Askie, L.1
  • 12
    • 0033966401 scopus 로고    scopus 로고
    • Supplemental therapeutic oxygen for prethreshold retinopathy of prematurity (STOP-ROP), a randomized, controlled trial. I: Primary outcomes
    • The STOP-ROP Multicenter Study Group
    • The STOP-ROP Multicenter Study Group. Supplemental therapeutic oxygen for prethreshold retinopathy of prematurity (STOP-ROP), a randomized, controlled trial. I: Primary outcomes. Pediatrics. 2000;105(2):295-310
    • (2000) Pediatrics , vol.105 , Issue.2 , pp. 295-310
  • 13
    • 0031265724 scopus 로고    scopus 로고
    • Supplemental oxygen may decrease progression of prethreshold disease to threshold retinopathy of prematurity
    • Gaynon MW, Stevenson DK, Sunshine P, Fleisher BE, Landers MB. Supplemental oxygen may decrease progression of prethreshold disease to threshold retinopathy of prematurity. J Perinatol. 1997;17(6):434-438
    • (1997) J Perinatol , vol.17 , Issue.6 , pp. 434-438
    • Gaynon, M.W.1    Stevenson, D.K.2    Sunshine, P.3    Fleisher, B.E.4    Landers, M.B.5
  • 15
    • 0042861328 scopus 로고    scopus 로고
    • Oxygen-saturation targets and outcomes in extremely premature infants
    • Askie LM, Henderson-Smart DJ, Irwig L, Simpson JM. Oxygen-saturation targets and outcomes in extremely premature infants. N Engl J Med. 2003;349(10):959-967
    • (2003) N Engl J Med , vol.349 , Issue.10 , pp. 959-967
    • Askie, L.M.1    Henderson-Smart, D.J.2    Irwig, L.3    Simpson, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.