메뉴 건너뛰기




Volumn 8, Issue 3, 2003, Pages 525-533

Near-infrared transmittance pulse oximetry with laser diodes

Author keywords

Laser diodes; Near infrared; Optical sensor; Pulse oximetry

Indexed keywords

HEMOGLOBIN OXYGEN SATURATION; INFRARED RADIATION; LIGHT TRANSMISSION; OXIMETERS; SEMICONDUCTOR LASERS;

EID: 1542679021     PISSN: 10833668     EISSN: None     Source Type: Journal    
DOI: 10.1117/1.1578495     Document Type: Article
Times cited : (29)

References (45)
  • 2
    • 0018924654 scopus 로고
    • Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
    • I. Yoshiya, Y. Shimada, and K. Tanaka, "Spectrophotometric monitoring of arterial oxygen saturation in the fingertip," Med. Biol. Eng. Comput. 18, 27-32 (1980).
    • (1980) Med. Biol. Eng. Comput. , vol.18 , pp. 27-32
    • Yoshiya, I.1    Shimada, Y.2    Tanaka, K.3
  • 3
    • 0004559226 scopus 로고
    • Non-invasive Spectrophotometric estimation of arterial oxygen saturation
    • Academic Press, New York
    • I. Yoshiya and Y. Shimada, "Non-invasive Spectrophotometric estimation of arterial oxygen saturation," in Noninvasive Physiological Measurements, Vol. 2, pp. 251-286, Academic Press, New York (1983).
    • (1983) Noninvasive Physiological Measurements , vol.2 , pp. 251-286
    • Yoshiya, I.1    Shimada, Y.2
  • 4
    • 0023402997 scopus 로고
    • Pulse oximetry: Technical aspects of machine design
    • J. A. Pologe, "Pulse oximetry: technical aspects of machine design," Int. Anesthesiol. Clin. 25, 137-153 (1987).
    • (1987) Int. Anesthesiol. Clin. , vol.25 , pp. 137-153
    • Pologe, J.A.1
  • 5
    • 0026629967 scopus 로고
    • Pulse oximetry: Theory and applications for noninvasive monitoring
    • Y. Mendelson, "Pulse oximetry: theory and applications for noninvasive monitoring," Clin. Chem. 38, 1601-1607 (1992).
    • (1992) Clin. Chem. , vol.38 , pp. 1601-1607
    • Mendelson, Y.1
  • 6
    • 0028946159 scopus 로고
    • Pulse oximetry-clinical implications and recent technical developments
    • L. G. Lindberg, C. Lennmarken, and M. Vegfors, "Pulse oximetry-clinical implications and recent technical developments," Acta Anesthesiol. Scand. 39, 279-287 (1995).
    • (1995) Acta Anesthesiol. Scand. , vol.39 , pp. 279-287
    • Lindberg, L.G.1    Lennmarken, C.2    Vegfors, M.3
  • 8
    • 0032278801 scopus 로고    scopus 로고
    • The ring sensor: A new ambulatory wearable sensor for twenty-four hour patient monitoring
    • S. Rhee, B. H. Yang, K. Chang, and H. H. Asada, "The ring sensor: a new ambulatory wearable sensor for twenty-four hour patient monitoring," Proc. 20th Ann. Int. Conf. IEEE/EMBS 4, 1906-1909 (1998).
    • (1998) Proc. 20th Ann. Int. Conf. IEEE/EMBS , vol.4 , pp. 1906-1909
    • Rhee, S.1    Yang, B.H.2    Chang, K.3    Asada, H.H.4
  • 9
    • 0033861042 scopus 로고    scopus 로고
    • Transophageal versus surface pulse oximetry in intensive care unit patients
    • M. N. Vincenzi, H. Gombotz, H. Krenn, C. Dorn, and P. Rehark, "Transophageal versus surface pulse oximetry in intensive care unit patients," Crit. Care Med. 28, 2268-2270 (2000).
    • (2000) Crit. Care Med. , vol.28 , pp. 2268-2270
    • Vincenzi, M.N.1    Gombotz, H.2    Krenn, H.3    Dorn, C.4    Rehark, P.5
  • 10
    • 0035073348 scopus 로고    scopus 로고
    • A new method for pulse oximetry possessing inherent insensitivity to artifact
    • M. J. Hayes and P. R. Smith, "A new method for pulse oximetry possessing inherent insensitivity to artifact," IEEE Trans. Biomed. Eng. 48, 452-461 (2001).
    • (2001) IEEE Trans. Biomed. Eng. , vol.48 , pp. 452-461
    • Hayes, M.J.1    Smith, P.R.2
  • 15
    • 0032278601 scopus 로고    scopus 로고
    • A novel hybrid reflectance pulse oximeter sensor with improved linearity and general applicability to various portions of the body
    • M. Nogawa, T. Kaiwa, and S. Takatani, "A novel hybrid reflectance pulse oximeter sensor with improved linearity and general applicability to various portions of the body," Proc. 20th Ann. Int. Conf. IEEE/EMBS 4, 1858-1861 (1998).
    • (1998) Proc. 20th Ann. Int. Conf. IEEE/EMBS , vol.4 , pp. 1858-1861
    • Nogawa, M.1    Kaiwa, T.2    Takatani, S.3
  • 16
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • F. F. Jöbsis, "Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters," Science (Washington, DC, U.S.) 198, 1264-1267 (1977).
    • (1977) Science (Washington, DC, U.S.) , vol.198 , pp. 1264-1267
    • Jöbsis, F.F.1
  • 17
    • 0000949236 scopus 로고    scopus 로고
    • Special section editorial: Near infrared spectroscopy and imaging of tissues
    • M. Ferrari, D. T. Delpy, and D. A. Benaron, "Special section editorial: near infrared spectroscopy and imaging of tissues," J. Biomed. Opt. 1, 361 (1996).
    • (1996) J. Biomed. Opt. , vol.1 , pp. 361
    • Ferrari, M.1    Delpy, D.T.2    Benaron, D.A.3
  • 18
    • 0021003005 scopus 로고
    • Spectrophotometry of hemoglobin and hemoglobin derivatives
    • E. J. Van Kampen and W. G. Zijlstra, "Spectrophotometry of hemoglobin and hemoglobin derivatives," Adv. Clin. Chem. 23, 199-257 (1983).
    • (1983) Adv. Clin. Chem. , vol.23 , pp. 199-257
    • Van Kampen, E.J.1    Zijlstra, W.G.2
  • 19
    • 0022894672 scopus 로고
    • Results of routine determination of clinically significant hemoglobin derivatives by multicomponent analysis
    • A. Zwart, E. J. Van Kampen, and W. G. Zijlstra, "Results of routine determination of clinically significant hemoglobin derivatives by multicomponent analysis," Clin. Chem. 32, 972-978 (1986).
    • (1986) Clin. Chem. , vol.32 , pp. 972-978
    • Zwart, A.1    Van Kampen, E.J.2    Zijlstra, W.G.3
  • 20
    • 0026005327 scopus 로고
    • Absorption spectra of human fetal and adult oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin and methemoglobin
    • W. G. Zijlstra, A. Buursma, and W. P. Meeuwsen van der Roest, "Absorption spectra of human fetal and adult oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin and methemoglobin," Clin. Chem. 37, 1633-1638 (1991).
    • (1991) Clin. Chem. , vol.37 , pp. 1633-1638
    • Zijlstra, W.G.1    Buursma, A.2    Van der Roest, W.P.M.3
  • 22
    • 0032640246 scopus 로고    scopus 로고
    • Application of NIR laser diodes to pulse oximetry
    • Biomedical Sensors, Fibers, and Optical Delivery Systems, Francesco Baldini, Nathan I. Croitoru, Ingemar Lundström, Mitsunobu Miyagi, Ricardo Pratesi, and Otto S. Wolfbeis, Eds.
    • S. M. López Silva, R. Giannetti, M. L. Dotor, J. R. Sendra, J. P. Silveira, and F. Briones, "Application of NIR laser diodes to pulse oximetry," in Biomedical Sensors, Fibers, and Optical Delivery Systems, Francesco Baldini, Nathan I. Croitoru, Ingemar Lundström, Mitsunobu Miyagi, Ricardo Pratesi, and Otto S. Wolfbeis, Eds., Proc. SPIE 3570, 294-302 (1998).
    • (1998) Proc. SPIE , vol.3570 , pp. 294-302
    • Silva, S.M.L.1    Giannetti, R.2    Dotor, M.L.3    Sendra, J.R.4    Silveira, J.P.5    Briones, F.6
  • 26
    • 0034938781 scopus 로고    scopus 로고
    • NIR transmittance pulse oximetry system with laser diodes
    • Clinical Diagnostic Systems, Gerald E. Cohn, Ed.
    • S. M. López Silva, J. P. Silveira, J. R. Sendra, R. Giannetti, M. L. Dotor, and D. Golmayo, "NIR transmittance pulse oximetry system with laser diodes," in Clinical Diagnostic Systems, Gerald E. Cohn, Ed., Proc. SPIE 4255, 80-87 (2001).
    • (2001) Proc. SPIE , vol.4255 , pp. 80-87
    • Silva, S.M.L.1    Silveira, J.P.2    Sendra, J.R.3    Giannetti, R.4    Dotor, M.L.5    Golmayo, D.6
  • 27
    • 0024713882 scopus 로고
    • Definition and notation of hemoglobin saturation
    • W. G. Zijlstra and B. Oeseburg, "Definition and notation of hemoglobin saturation," IEEE Trans. Biomed. Eng. 36, 872 (1989).
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 872
    • Zijlstra, W.G.1    Oeseburg, B.2
  • 28
    • 0026335383 scopus 로고
    • Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
    • J. M. Schmitt, "Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry," IEEE Trans. Biomed. Eng. 38, 1194-1203 (1991).
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 1194-1203
    • Schmitt, J.M.1
  • 29
    • 0028403693 scopus 로고
    • Diffusion-based model of pulse oximetry: In vitro and vivo comparisons
    • D. R. Marble, D. H. Burns, and P. W. Cheung, "Diffusion-based model of pulse oximetry: In vitro and vivo comparisons," Appl. Opt. 33, 1279-1285 (1994).
    • (1994) Appl. Opt. , vol.33 , pp. 1279-1285
    • Marble, D.R.1    Burns, D.H.2    Cheung, P.W.3
  • 30
    • 0021489638 scopus 로고
    • Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter on the fingertip
    • Y. Shimada, I. Yoshiya, N. Oka, and K. Hamaguri, "Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter on the fingertip," Med. Biol. Eng. Comput. 22, 475-478 (1984).
    • (1984) Med. Biol. Eng. Comput. , vol.22 , pp. 475-478
    • Shimada, Y.1    Yoshiya, I.2    Oka, N.3    Hamaguri, K.4
  • 33
    • 0024713904 scopus 로고
    • Variations in optical absorption spectra of adult and fetal hemoglobin and its effects on pulse oximetry
    • Y. Mendelson and J. C. Kent, "Variations in optical absorption spectra of adult and fetal hemoglobin and its effects on pulse oximetry," IEEE Trans. Biomed. Eng. 36, 844-848 (1989).
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 844-848
    • Mendelson, Y.1    Kent, J.C.2
  • 34
    • 0141762864 scopus 로고    scopus 로고
    • http://www.gmi-inc.com/Categories/bloodgas.htm
  • 35
    • 0000004140 scopus 로고
    • Measurements in medicine: The analysis of method comparison studies
    • D. G. Altman and J. M. Bland, "Measurements in medicine: the analysis of method comparison studies," Statistician 32, 307-317 (1983).
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 36
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measures
    • J. M. Bland and D. G. Altman, "Statistical methods for assessing agreement between two methods of clinical measures," Lancet 1, 307-311 (1986).
    • (1986) Lancet , vol.1 , pp. 307-311
    • Bland, J.M.1    Altman, D.G.2
  • 37
    • 0030032809 scopus 로고    scopus 로고
    • Uses and abuses of pulse oximetry
    • J. T. B. Moyle, "Uses and abuses of pulse oximetry," Arch. Dis. Child. 74, 77-80 (1996).
    • (1996) Arch. Dis. Child. , vol.74 , pp. 77-80
    • Moyle, J.T.B.1
  • 39
    • 0024474896 scopus 로고
    • An in vitro tissue model for evaluating the effect of carboxyhemoglobin concentration on pulse
    • Y. Mendelson and J. C. Kent, "An in vitro tissue model for evaluating the effect of carboxyhemoglobin concentration on pulse," IEEE Trans. Biomed. Eng. 36, 625-627 (1989).
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 625-627
    • Mendelson, Y.1    Kent, J.C.2
  • 40
    • 0031763681 scopus 로고    scopus 로고
    • Pulse oximetry in severe carbon monoxide poisoning
    • N. B. Hampson, "Pulse oximetry in severe carbon monoxide poisoning," Chest 114, 1036-1041 (1998).
    • (1998) Chest , vol.114 , pp. 1036-1041
    • Hampson, N.B.1
  • 41
    • 0034234391 scopus 로고    scopus 로고
    • The accuracy of pulse oximetry in the emergency department
    • W. W. Lee, K. Mayberry, R. Crapo, and R. L. Jensen, "The accuracy of pulse oximetry in the emergency department," Am. J. Emerg. Med. 18, 427-431 (2000).
    • (2000) Am. J. Emerg. Med. , vol.18 , pp. 427-431
    • Lee, W.W.1    Mayberry, K.2    Crapo, R.3    Jensen, R.L.4
  • 43
    • 0002794690 scopus 로고    scopus 로고
    • Reflectance pulse oximetry (RPOX): Two sensors compared in piglets
    • R. Nijland, H. W. Jongsma, and J. G. Nijhuis, "Reflectance pulse oximetry (RPOX): Two sensors compared in piglets," Am. J. Obstet Gynecol. 172, 365 (1997).
    • (1997) Am. J. Obstet Gynecol. , vol.172 , pp. 365
    • Nijland, R.1    Jongsma, H.W.2    Nijhuis, J.G.3
  • 44
    • 0015604413 scopus 로고
    • Optical constants of water in the 200 nm to 200 μm wavelength region
    • G. M. Hale and M. R. Querry, "Optical constants of water in the 200 nm to 200 μm wavelength region," Appl. Opt. 12, 555-563 (1973).
    • (1973) Appl. Opt. , vol.12 , pp. 555-563
    • Hale, G.M.1    Querry, M.R.2
  • 45
    • 0030411629 scopus 로고    scopus 로고
    • Multiwavelength pulse oximetry in the measurement of hemoglobin fractions
    • Biomedical Sensing and Tracking Technologies I, Robert A. Lieberman, Halina Pobdielska, and Tuan Vo-Dinh, Eds.
    • B. Manzke, J. Schwider, N. Lutter, K. Ehgelhardt, and W. Stork, "Multiwavelength pulse oximetry in the measurement of hemoglobin fractions," in Biomedical Sensing and Tracking Technologies I, Robert A. Lieberman, Halina Pobdielska, and Tuan Vo-Dinh, Eds., Proc. SPIE 2676, 332-340 (1996).
    • (1996) Proc. SPIE , vol.2676 , pp. 332-340
    • Manzke, B.1    Schwider, J.2    Lutter, N.3    Ehgelhardt, K.4    Stork, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.