메뉴 건너뛰기




Volumn 31, Issue 1, 2010, Pages 227-233

Improved correction of spatial inhomogeneities of surface coils in quantitative analysis of first-pass myocardial perfusion imaging

Author keywords

Absolute perfusion; First pass; Myocardial perfusion; Normalization; RF coil inhomogeneity

Indexed keywords

GADOLINIUM PENTETATE;

EID: 74049114094     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21998     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi model of constrained deconvolution
    • Jerosch-Herold M, Wilke N, Stillman A. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi model of constrained deconvolution. Med Phys 1998;25:73-84.
    • (1998) Med Phys , vol.25 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.3
  • 2
    • 14044253531 scopus 로고    scopus 로고
    • Multislice MR first-pass myocardial perfusion imaging: Impact of the receiver coil array
    • Hoffmann M, Schmid F, Jeltsch M, et al. Multislice MR first-pass myocardial perfusion imaging: impact of the receiver coil array. J Magn Reson Imaging 2005;21:310-316.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 310-316
    • Hoffmann, M.1    Schmid, F.2    Jeltsch, M.3
  • 3
    • 0029972766 scopus 로고    scopus 로고
    • Intensity correction of phased-array surface coil images
    • Murakami JW, Hayes CE, Weinberger E. Intensity correction of phased-array surface coil images. Magn Reson Med 1996;35:585-590.
    • (1996) Magn Reson Med , vol.35 , pp. 585-590
    • Murakami, J.W.1    Hayes, C.E.2    Weinberger, E.3
  • 5
    • 11244299293 scopus 로고    scopus 로고
    • Surface coil intensity correction and non-linear intensity normalization improve pixel-resolution parametric maps of myocardial MRI perfusion
    • Ellis RE, Peters TM, editors, Lecture notes in computer science 2003. Berlin: Springer-Verlag
    • Hsu LY, Rhoads KL, Aletras AH, et al. Surface coil intensity correction and non-linear intensity normalization improve pixel-resolution parametric maps of myocardial MRI perfusion. In: Ellis RE, Peters TM, editors. Medical image computing and computerassisted intervention - MICCAI. Lecture notes in computer science 2003. Berlin: Springer-Verlag, Vol. 2879, p 975-976.
    • Medical image computing and computerassisted intervention - MICCAI , vol.2879 , pp. 975-976
    • Hsu, L.Y.1    Rhoads, K.L.2    Aletras, A.H.3
  • 6
    • 33646171477 scopus 로고    scopus 로고
    • Theory-based signal calibration with singlepoint T1 measurements for first-pass quantitative perfusion MRI studies
    • Cernicanu A, Axel L. Theory-based signal calibration with singlepoint T1 measurements for first-pass quantitative perfusion MRI studies. Acad Radiol 2006;13:686-693.
    • (2006) Acad Radiol , vol.13 , pp. 686-693
    • Cernicanu, A.1    Axel, L.2
  • 7
    • 33644848092 scopus 로고    scopus 로고
    • Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans
    • Hsu LY, Rhoads KL, Holly JE, Kellman P, Aletras AH, Arai AE. Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging 2006;23:315-322.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 315-322
    • Hsu, L.Y.1    Rhoads, K.L.2    Holly, J.E.3    Kellman, P.4    Aletras, A.H.5    Arai, A.E.6
  • 9
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45:846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 11
    • 0024368647 scopus 로고
    • Regional myocardial flow heterogeneity explained with fractal networks
    • Van Beek JHGM, Roger SA, Bassingthwaighte JB. Regional myocardial flow heterogeneity explained with fractal networks. Am J Physiol 1989;257:1670-1680.
    • (1989) Am J Physiol , vol.257 , pp. 1670-1680
    • Van Beek, J.H.G.M.1    Roger, S.A.2    Bassingthwaighte, J.B.3
  • 12
    • 33845313632 scopus 로고    scopus 로고
    • Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance
    • Maceira AM, Prasad SK, Khan M, Pennell DJ. Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J 2006;27:2879-2888.
    • (2006) Eur Heart J , vol.27 , pp. 2879-2888
    • Maceira, A.M.1    Prasad, S.K.2    Khan, M.3    Pennell, D.J.4
  • 14
    • 0024440958 scopus 로고
    • Fractal nature of regional myocardial blood flow heterogeneity
    • Bassingthwaighte JB, King RB, Roger SA. Fractal nature of regional myocardial blood flow heterogeneity. Circ Res 1989;65:589-590.
    • (1989) Circ Res , vol.65 , pp. 589-590
    • Bassingthwaighte, J.B.1    King, R.B.2    Roger, S.A.3
  • 15
    • 0030751213 scopus 로고    scopus 로고
    • Myocardial perfusion reserve: Assessment with multisection, quantitative, first-pass imaging
    • Wilke N, Jerosch-Herold M, Wang Y, et al. Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass imaging. Radiology 1997;204:373-384.
    • (1997) Radiology , vol.204 , pp. 373-384
    • Wilke, N.1    Jerosch-Herold, M.2    Wang, Y.3
  • 16
    • 33645766452 scopus 로고    scopus 로고
    • Comparison of MRI and positron emission tomography for measuring myocardial perfusion reserve in healthy humans
    • Parkka J, Niemi P, Saraste A, et al. Comparison of MRI and positron emission tomography for measuring myocardial perfusion reserve in healthy humans. Magn Reson Med 2006;55:772-779.
    • (2006) Magn Reson Med , vol.55 , pp. 772-779
    • Parkka, J.1    Niemi, P.2    Saraste, A.3
  • 18
    • 0021948756 scopus 로고    scopus 로고
    • Henkelman RM. Measurements of signal intensity in the presence of noise in MR images. Med Phys 1985;12:232-233 [erratum:1986;13:1544].
    • Henkelman RM. Measurements of signal intensity in the presence of noise in MR images. Med Phys 1985;12:232-233 [erratum:1986;13:1544].
  • 19
    • 28544436974 scopus 로고    scopus 로고
    • 1-insensitive uniform T1-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging
    • 1-insensitive uniform T1-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging. Magn Reson Med 2005;54:1423-1429.
    • (2005) Magn Reson Med , vol.54 , pp. 1423-1429
    • Kim, D.1    Cernicanu, A.2    Axel, L.3
  • 20
    • 74049121765 scopus 로고    scopus 로고
    • A comparison of two different field insensitive saturation pulses for improved uniformity in myocardial perfusion imaging at 3T
    • Zühlsdorff S, Weale PJ, Kino A, Carr JC, Jerecic R. A comparison of two different field insensitive saturation pulses for improved uniformity in myocardial perfusion imaging at 3T. J Cardiovasc Magn Reson 2007;9:p 626.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 626
    • Zühlsdorff, S.1    Weale, P.J.2    Kino, A.3    Carr, J.C.4    Jerecic, R.5
  • 21
    • 37149031243 scopus 로고    scopus 로고
    • 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: A systematic review and meta-analysis
    • Abdulla J, Abildstrom SZ, Gotzsche O, Christensen E, Kober L, Torp-Pedersen C. 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis. Eur Heart J 2007;28:3042-3050.
    • (2007) Eur Heart J , vol.28 , pp. 3042-3050
    • Abdulla, J.1    Abildstrom, S.Z.2    Gotzsche, O.3    Christensen, E.4    Kober, L.5    Torp-Pedersen, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.