-
1
-
-
0032435894
-
Monte Carlo treatment planning for stereotactic radiosurgery
-
10.1016/S0167-8140(98)00065-6, 9886701
-
Solberg TD, DeMarco JJ, Holly FE, Smathers JB, DeSalles AA. Monte Carlo treatment planning for stereotactic radiosurgery. Radiother Oncol 1998, 49:73-84. 10.1016/S0167-8140(98)00065-6, 9886701.
-
(1998)
Radiother Oncol
, vol.49
, pp. 73-84
-
-
Solberg, T.D.1
DeMarco, J.J.2
Holly, F.E.3
Smathers, J.B.4
DeSalles, A.A.5
-
2
-
-
0032724373
-
Clinical implementation of a Monte Carlo treatment planning system
-
10.1118/1.598729, 10535630
-
Ma CM, Mok E, Kapur A, Pawlicki T, Findley D, Brain S, Forster K, Boyer AL. Clinical implementation of a Monte Carlo treatment planning system. Med Phys 1999, 26(10):2133-43. 10.1118/1.598729, 10535630.
-
(1999)
Med Phys
, vol.26
, Issue.10
, pp. 2133-2143
-
-
Ma, C.M.1
Mok, E.2
Kapur, A.3
Pawlicki, T.4
Findley, D.5
Brain, S.6
Forster, K.7
Boyer, A.L.8
-
3
-
-
22844452234
-
Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems
-
10.1088/0031-9155/50/9/009, 15843736
-
Paelinck L, Reynaert N, Thierens H, De Neve W, De Wagter C. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems. Phys Med Biol 2005, 50(9):2055-69. 10.1088/0031-9155/50/9/009, 15843736.
-
(2005)
Phys Med Biol
, vol.50
, Issue.9
, pp. 2055-2069
-
-
Paelinck, L.1
Reynaert, N.2
Thierens, H.3
De Neve, W.4
De Wagter, C.5
-
4
-
-
0343602910
-
The impact of electron transport on the accuracy of computed dose
-
10.1118/1.599004, 10902555
-
Arnfield MR, Siantar CH, Siebers J, Garmon P, Cox L, Mohan R. The impact of electron transport on the accuracy of computed dose. Med Phys 2000, 27(6):1266-74. 10.1118/1.599004, 10902555.
-
(2000)
Med Phys
, vol.27
, Issue.6
, pp. 1266-1274
-
-
Arnfield, M.R.1
Siantar, C.H.2
Siebers, J.3
Garmon, P.4
Cox, L.5
Mohan, R.6
-
5
-
-
0028897629
-
Implications of tissue heterogeneity for radiosurgery in head and neck tumors
-
Solberg TD, Holly FE, De Salles AA, Wallace RE, Smathers JB. Implications of tissue heterogeneity for radiosurgery in head and neck tumors. Int J Radiat Oncol Biol Phys 1995, 32:235-9.
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.32
, pp. 235-239
-
-
Solberg, T.D.1
Holly, F.E.2
De Salles, A.A.3
Wallace, R.E.4
Smathers, J.B.5
-
6
-
-
0141849098
-
Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning
-
10.1088/0031-9155/48/17/309, 14516106
-
Aspradakis MM, Morrison RH, Richmond ND, Steele A. Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning. Phys Med Biol 2003, 48(17):2873-93. 10.1088/0031-9155/48/17/309, 14516106.
-
(2003)
Phys Med Biol
, vol.48
, Issue.17
, pp. 2873-2893
-
-
Aspradakis, M.M.1
Morrison, R.H.2
Richmond, N.D.3
Steele, A.4
-
7
-
-
4043179433
-
Dose calculation accuracy of lung planning with a commercial IMRT treatment planning system
-
10.1120/1.1623172, 14604424
-
McDermott PN, He T, DeYoung A. Dose calculation accuracy of lung planning with a commercial IMRT treatment planning system. J Appl Clin Med Phys 2003, 4(4):341-51. 10.1120/1.1623172, 14604424.
-
(2003)
J Appl Clin Med Phys
, vol.4
, Issue.4
, pp. 341-351
-
-
McDermott, P.N.1
He, T.2
DeYoung, A.3
-
8
-
-
1942420351
-
Analysis of the penumbra enlargement in lung versus the quality index of photon beams: a methodology to check the dose calculation algorithm
-
10.1118/1.1669085, 15125013
-
Tsiakalos MF, Theodorou K, Kappas C, Zefkili S, Rosenwold JC. Analysis of the penumbra enlargement in lung versus the quality index of photon beams: a methodology to check the dose calculation algorithm. Med Phys 2004, 31(4):943-9. 10.1118/1.1669085, 15125013.
-
(2004)
Med Phys
, vol.31
, Issue.4
, pp. 943-949
-
-
Tsiakalos, M.F.1
Theodorou, K.2
Kappas, C.3
Zefkili, S.4
Rosenwold, J.C.5
-
9
-
-
4544227860
-
Investigation of photon beam models in heterogeneous media of modern radiotherapy
-
10.1007/BF03178375, 15462585
-
Ding W, Johnston PN, Wong TPY, Bubb IF. Investigation of photon beam models in heterogeneous media of modern radiotherapy. Australas Phys Eng Sci Med 2004, 27(2):39-48. 10.1007/BF03178375, 15462585.
-
(2004)
Australas Phys Eng Sci Med
, vol.27
, Issue.2
, pp. 39-48
-
-
Ding, W.1
Johnston, P.N.2
Wong, T.P.Y.3
Bubb, I.F.4
-
10
-
-
34248329093
-
Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms
-
10.1186/1748-717X-1-45, 1769387, 17132177
-
Dobler B, Walter C, Knopf A, Fabri D, Loeschel R, Polednik M, Schneider F, Wenz F, Lohr F. Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms. Radiat Oncol 2006, 1:45. 10.1186/1748-717X-1-45, 1769387, 17132177.
-
(2006)
Radiat Oncol
, vol.1
, pp. 45
-
-
Dobler, B.1
Walter, C.2
Knopf, A.3
Fabri, D.4
Loeschel, R.5
Polednik, M.6
Schneider, F.7
Wenz, F.8
Lohr, F.9
-
11
-
-
7244223251
-
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
-
10.1118/1.1788932, 15543799
-
Carrasco P, Jornet N, Duch MA, Weber L, Ginjaume M, Eudaldo T, Jurado D, Ruiz A, Ribas M. Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium. Med Phys 2004, 31(10):2899-911. 10.1118/1.1788932, 15543799.
-
(2004)
Med Phys
, vol.31
, Issue.10
, pp. 2899-2911
-
-
Carrasco, P.1
Jornet, N.2
Duch, M.A.3
Weber, L.4
Ginjaume, M.5
Eudaldo, T.6
Jurado, D.7
Ruiz, A.8
Ribas, M.9
-
12
-
-
16444375876
-
Monte Carlo-versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom
-
10.1088/0031-9155/50/5/010, 15798260
-
Krieger T, Sauer OA. Monte Carlo-versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom. Physics in Medicine and Biology 2005, 50(5):859-868. 10.1088/0031-9155/50/5/010, 15798260.
-
(2005)
Physics in Medicine and Biology
, vol.50
, Issue.5
, pp. 859-868
-
-
Krieger, T.1
Sauer, O.A.2
-
13
-
-
0346994900
-
Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapy
-
10.1118/1.1626990, 14713087
-
Fraass BA, Smathers J, Deye J. Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapy. Med Phys 2003, 30(12):3206-16. 10.1118/1.1626990, 14713087.
-
(2003)
Med Phys
, vol.30
, Issue.12
, pp. 3206-3216
-
-
Fraass, B.A.1
Smathers, J.2
Deye, J.3
-
14
-
-
33750574559
-
Testing of the analytical anisotropic algorithm for photon dose calculation
-
10.1118/1.2358333, 17153392
-
Van Esch A, Tillikainen L, Pyykkonen J, Tenhunen M, Helminen H, Siljamäki S, Alakuijala J, Paiusco M, Lori M, Huyskens DP. Testing of the analytical anisotropic algorithm for photon dose calculation. Med Phys 2006, 33(11):4130-48. 10.1118/1.2358333, 17153392.
-
(2006)
Med Phys
, vol.33
, Issue.11
, pp. 4130-4148
-
-
Van Esch, A.1
Tillikainen, L.2
Pyykkonen, J.3
Tenhunen, M.4
Helminen, H.5
Siljamäki, S.6
Alakuijala, J.7
Paiusco, M.8
Lori, M.9
Huyskens, D.P.10
-
15
-
-
0037340926
-
A virtual photon energy fluence model for Monte Carlo dose calculation
-
10.1118/1.1543152, 12674229
-
Fippel M, Haryanto F, Dohm O, Nusslin F, Kriesen S. A virtual photon energy fluence model for Monte Carlo dose calculation. Medical Physics 2003, 30(3):301-311. 10.1118/1.1543152, 12674229.
-
(2003)
Medical Physics
, vol.30
, Issue.3
, pp. 301-311
-
-
Fippel, M.1
Haryanto, F.2
Dohm, O.3
Nusslin, F.4
Kriesen, S.5
-
16
-
-
34547099077
-
A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation
-
10.1088/0031-9155/52/15/006, 17634643
-
Sikora M, Dohm O, Alber M. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation. Phys Med Biol 2007, 52(15):4449-63. 10.1088/0031-9155/52/15/006, 17634643.
-
(2007)
Phys Med Biol
, vol.52
, Issue.15
, pp. 4449-4463
-
-
Sikora, M.1
Dohm, O.2
Alber, M.3
-
17
-
-
0033916364
-
Monte Carlo dose computation for IMRT optimization
-
10.1088/0031-9155/45/7/303, 10943916
-
Laub W, Alber M, Birkner M, Nüsslin F. Monte Carlo dose computation for IMRT optimization. Phys Med Biol 2000, 45(7):1741-54. 10.1088/0031-9155/45/7/303, 10943916.
-
(2000)
Phys Med Biol
, vol.45
, Issue.7
, pp. 1741-1754
-
-
Laub, W.1
Alber, M.2
Birkner, M.3
Nüsslin, F.4
-
18
-
-
0001786004
-
Hyperion: An integrated IMRT planning tool
-
Springer-Verlag Berlin Heidelberg New York, schlegel w, bortfeld t
-
Alber M, Birkner M, Laub W, Nüsslin F. Hyperion: An integrated IMRT planning tool. 13th International Conference on the Use of Computers in Radiation Therapy, Heidelberg Germany 2000, 46-48. Springer-Verlag Berlin Heidelberg New York, schlegel w, bortfeld t.
-
(2000)
13th International Conference on the Use of Computers in Radiation Therapy, Heidelberg Germany
, pp. 46-48
-
-
Alber, M.1
Birkner, M.2
Laub, W.3
Nüsslin, F.4
-
19
-
-
0032772588
-
Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
-
10.1118/1.598676, 10501045
-
Fippel M. Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm. Med Phys 1999, 26(8):1466-75. 10.1118/1.598676, 10501045.
-
(1999)
Med Phys
, vol.26
, Issue.8
, pp. 1466-1475
-
-
Fippel, M.1
-
20
-
-
70349557922
-
Intensity-modulated radiotherapy optimization in a quasi-periodically deforming patient model
-
Söhn M, Weinmann M, Alber M. Intensity-modulated radiotherapy optimization in a quasi-periodically deforming patient model. Int J Radiat Oncol Biol Phys 2009, 75(3):906-14.
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.75
, Issue.3
, pp. 906-914
-
-
Söhn, M.1
Weinmann, M.2
Alber, M.3
-
21
-
-
22844434023
-
A finite size pencil beam for IMRT dose optimization
-
10.1088/0031-9155/50/8/009, 15815094
-
Jeleń U, Söhn M, Alber M. A finite size pencil beam for IMRT dose optimization. Phys Med Biol 2005, 50(8):1747-66. 10.1088/0031-9155/50/8/009, 15815094.
-
(2005)
Phys Med Biol
, vol.50
, Issue.8
, pp. 1747-1766
-
-
Jeleń, U.1
Söhn, M.2
Alber, M.3
-
22
-
-
34047264289
-
A finite size pencil beam algorithm for IMRT dose optimization: density corrections
-
10.1088/0031-9155/52/3/006, 17228109
-
Jeleń U, Alber M. A finite size pencil beam algorithm for IMRT dose optimization: density corrections. Phys Med Biol 2007, 52(3):617-33. 10.1088/0031-9155/52/3/006, 17228109.
-
(2007)
Phys Med Biol
, vol.52
, Issue.3
, pp. 617-633
-
-
Jeleń, U.1
Alber, M.2
-
23
-
-
0242606142
-
A revision of the gamma-evaluation concept for the comparison of dose distributions
-
Bakai A, Alber M, Nüsslin F. A revision of the gamma-evaluation concept for the comparison of dose distributions. Phys MedBiol 2003, 48(21):3543-53.
-
(2003)
Phys MedBiol
, vol.48
, Issue.21
, pp. 3543-3553
-
-
Bakai, A.1
Alber, M.2
Nüsslin, F.3
-
24
-
-
0039728357
-
An objective function for radiation treatment optimization based on local biological measures
-
10.1088/0031-9155/44/2/014, 10070796
-
Alber M, Nüsslin F. An objective function for radiation treatment optimization based on local biological measures. Phys Med Biol 1999, 44(2):479-93. 10.1088/0031-9155/44/2/014, 10070796.
-
(1999)
Phys Med Biol
, vol.44
, Issue.2
, pp. 479-493
-
-
Alber, M.1
Nüsslin, F.2
-
25
-
-
44449132187
-
Normal tissue dose-effect models in biological dose optimisation
-
Alber M. Normal tissue dose-effect models in biological dose optimisation. Z Med Phys 2008, 18(2):102-10.
-
(2008)
Z Med Phys
, vol.18
, Issue.2
, pp. 102-110
-
-
Alber, M.1
-
26
-
-
0031037018
-
Reporting and analyzing dose distributions: a concept of equivalent uniform dose
-
10.1118/1.598063, 9029544
-
Niemierko A. Reporting and analyzing dose distributions: a concept of equivalent uniform dose. Med Phys 1997, 24:103-10. 10.1118/1.598063, 9029544.
-
(1997)
Med Phys
, vol.24
, pp. 103-110
-
-
Niemierko, A.1
-
27
-
-
0035739248
-
Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery
-
10.1088/0031-9155/46/12/311, 11768502
-
Alber M, Nüsslin F. Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. Phys Med Biol 2001, 46(12):3229-39. 10.1088/0031-9155/46/12/311, 11768502.
-
(2001)
Phys Med Biol
, vol.46
, Issue.12
, pp. 3229-3239
-
-
Alber, M.1
Nüsslin, F.2
-
28
-
-
0035996450
-
Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations
-
10.1118/1.1487421, 12148735
-
Martens C, Reynaert N, De Wagter C, Nilsson P, Coghe M, Palmans H, Thierens H, De Neve W. Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations. Med Phys 2002, 29(7):1528-35. 10.1118/1.1487421, 12148735.
-
(2002)
Med Phys
, vol.29
, Issue.7
, pp. 1528-1535
-
-
Martens, C.1
Reynaert, N.2
De Wagter, C.3
Nilsson, P.4
Coghe, M.5
Palmans, H.6
Thierens, H.7
De Neve, W.8
-
29
-
-
33748297735
-
Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
-
10.1118/1.2241992, 17022207
-
Vanderstraeten B, Reynaert N, Paelinck L, Madani I, De Wagter C, De Gersem W, De Neve W, Thierens H. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations. Med Phys 2006, 33(9):3149-58. 10.1118/1.2241992, 17022207.
-
(2006)
Med Phys
, vol.33
, Issue.9
, pp. 3149-3158
-
-
Vanderstraeten, B.1
Reynaert, N.2
Paelinck, L.3
Madani, I.4
De Wagter, C.5
De Gersem, W.6
De Neve, W.7
Thierens, H.8
|