Volumn 109, Issue 6, 2009, Pages 1847-1849

A comparison of transmittance and reflectance pulse oximetry during vascular surgery

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTERIAL GAS; ARTICLE; CLINICAL ARTICLE; COMPARATIVE STUDY; EAR LOBE; FOREHEAD; GENERAL ANESTHESIA; HUMAN; OXYGEN SATURATION; PATIENT MONITORING; PERIPHERAL VASCULAR DISEASE; PRIORITY JOURNAL; PULSE OXIMETRY; REFLECTANCE PULSE OXIMETRY; RELIABILITY; TRANSMITTANCE PULSE OXIMETRY; VASCULAR SURGERY;

EID: 73949149002     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ANE.0b013e3181bbc446     Document Type: Article
Times cited : (28)

References (14)
  • 1
    • 0031789435 scopus 로고    scopus 로고
    • Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
    • Jensen LA, Onyskiw JE, Prasad NG. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults. Heart Lung 1998;27:387-408
    • (1998) Heart Lung , vol.27 , pp. 387-408
    • Jensen, L.A.1    Onyskiw, J.E.2    Prasad, N.G.3
  • 3
    • 4644253524 scopus 로고    scopus 로고
    • Forehead oximetry in critically ill patients: The case for a new monitoring site
    • Branson RD, Mannheimer PD. Forehead oximetry in critically ill patients: the case for a new monitoring site. Respir Care Clin N Am 2004;10:359-367
    • (2004) Respir Care Clin N Am , vol.10 , pp. 359-367
    • Branson, R.D.1    Mannheimer, P.D.2
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 34248150312 scopus 로고    scopus 로고
    • Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion
    • Schallom L, Sona C, McSweeney M, Mazuski J. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion. Heart Lung 2007;36:188-194
    • (2007) Heart Lung , vol.36 , pp. 188-194
    • Schallom, L.1    Sona, C.2    McSweeney, M.3    Mazuski, J.4
  • 12
    • 2342448478 scopus 로고    scopus 로고
    • Forehead is as sensitive as finger pulse oximetry during general anesthesia
    • Sugino S, Kanaya N, Mizuuchi M, Nakayama M, Namiki A. Forehead is as sensitive as finger pulse oximetry during general anesthesia. Can J Anesth 2004;51:432-436
    • (2004) Can J Anesth , vol.51 , pp. 432-436
    • Sugino, S.1    Kanaya, N.2    Mizuuchi, M.3    Nakayama, M.4    Namiki, A.5
  • 13
    • 34548610952 scopus 로고    scopus 로고
    • Forehead reflectance oximetry: A clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery
    • Casati A, Squicciarini G, Baciarello M, Putzu M, Salvadori A, Fanelli G. Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery. J Clin Monit Comput 2007;21:271-276
    • (2007) J Clin Monit Comput , vol.21 , pp. 271-276
    • Casati, A.1    Squicciarini, G.2    Baciarello, M.3    Putzu, M.4    Salvadori, A.5    Fanelli, G.6
  • 14
    • 34547957209 scopus 로고    scopus 로고
    • Pulse oximetry to detect hypoxemia during apnea: Comparison of finger and ear probes
    • Lindholm P, Blogg S, Gennser M. Pulse oximetry to detect hypoxemia during apnea: comparison of finger and ear probes. Aviat Space Environ Med 2007;78:770-773
    • (2007) Aviat Space Environ Med , vol.78 , pp. 770-773
    • Lindholm, P.1    Blogg, S.2    Gennser, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.