메뉴 건너뛰기




Volumn 68, Issue 2, 2010, Pages 399-406

Feasibility Study of a Partially Hollow Configuration for Zirconia Dental Implants

Author keywords

[No Author keywords available]

Indexed keywords

METHACRYLIC ACID METHYL ESTER; ZIRCONIUM OXIDE;

EID: 73949120446     PISSN: 02782391     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joms.2009.10.001     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 32244447142 scopus 로고    scopus 로고
    • Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study
    • Att W., Kurun S., Gerds T., et al. Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study. J Prosthet Dent 95 (2006) 111
    • (2006) J Prosthet Dent , vol.95 , pp. 111
    • Att, W.1    Kurun, S.2    Gerds, T.3
  • 3
    • 0031467964 scopus 로고    scopus 로고
    • Standardization of zirconia ceramics for hip endoprostheses
    • Willmann G. Standardization of zirconia ceramics for hip endoprostheses. Biomed Tech (Berl) 42 (1997) 342
    • (1997) Biomed Tech (Berl) , vol.42 , pp. 342
    • Willmann, G.1
  • 4
    • 0027607307 scopus 로고
    • Time dependent changes in the mechanical properties of zirconia ceramic
    • Shimizu K., Oka M., Kumar P., Kotoura Y., et al. Time dependent changes in the mechanical properties of zirconia ceramic. J Biomed Mater Res 27 (1993) 729
    • (1993) J Biomed Mater Res , vol.27 , pp. 729
    • Shimizu, K.1    Oka, M.2    Kumar, P.3    Kotoura, Y.4
  • 5
    • 0035108581 scopus 로고    scopus 로고
    • Biocompatibility and osteointegration in osteoporotic bone
    • Fini M., Giavariesi G., Torricelli P., et al. Biocompatibility and osteointegration in osteoporotic bone. J Bone Joint Surg Br 83 (2001) 139
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 139
    • Fini, M.1    Giavariesi, G.2    Torricelli, P.3
  • 6
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D.S., and Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants 4 (1989) 40
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 40
    • Siegele, D.S.1    Soltesz, U.2
  • 7
    • 0032233320 scopus 로고    scopus 로고
    • Guidelines for analysis and redesign of dental implants
    • Patra A.K., Depaolo J.M., Souza K.S., et al. Guidelines for analysis and redesign of dental implants. Implant Dent 7 (1998) 68
    • (1998) Implant Dent , vol.7 , pp. 68
    • Patra, A.K.1    Depaolo, J.M.2    Souza, K.S.3
  • 8
    • 0024675462 scopus 로고
    • Bone resorption at the entry of osseointegrated implants-A biomechanical phenomenon
    • Mailth G., Stoiber B., Watzek G., et al. Bone resorption at the entry of osseointegrated implants-A biomechanical phenomenon. Z Stomatol 86 (1989) 207
    • (1989) Z Stomatol , vol.86 , pp. 207
    • Mailth, G.1    Stoiber, B.2    Watzek, G.3
  • 9
    • 73949086707 scopus 로고
    • Biomechanical designing of implants
    • Tsutsumi S., Fukuda Y., and Tani Y. Biomechanical designing of implants. J Dent Res 68 (1989) 754
    • (1989) J Dent Res , vol.68 , pp. 754
    • Tsutsumi, S.1    Fukuda, Y.2    Tani, Y.3
  • 10
    • 33750597048 scopus 로고    scopus 로고
    • A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part I. Review of literature
    • Szucs A., Divinyi T., Lorincz A., et al. A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part I. Review of literature. Fogorv Sz 99 (2006) 141
    • (2006) Fogorv Sz , vol.99 , pp. 141
    • Szucs, A.1    Divinyi, T.2    Lorincz, A.3
  • 11
    • 39049182366 scopus 로고    scopus 로고
    • A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part II. Experiments
    • Szucs A., Divinyi T., and Bojtár I. A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part II. Experiments. Fogorv Sz 99 (2006) 187
    • (2006) Fogorv Sz , vol.99 , pp. 187
    • Szucs, A.1    Divinyi, T.2    Bojtár, I.3
  • 12
    • 25844483285 scopus 로고    scopus 로고
    • Effect of implant size and shape on implant success rates: A literature review
    • Lee J.H., Frias V., Lee K.W., et al. Effect of implant size and shape on implant success rates: A literature review. J Prosthet Dent 94 (2005) 377
    • (2005) J Prosthet Dent , vol.94 , pp. 377
    • Lee, J.H.1    Frias, V.2    Lee, K.W.3
  • 13
    • 0033999739 scopus 로고    scopus 로고
    • Coatings of zirconia for medical applications
    • Ferraris M., Verne E., Appendino P., et al. Coatings of zirconia for medical applications. Biomaterials 21 (2000) 765
    • (2000) Biomaterials , vol.21 , pp. 765
    • Ferraris, M.1    Verne, E.2    Appendino, P.3
  • 17
    • 33645243940 scopus 로고    scopus 로고
    • Scanning electron microscopy and energy dispersive X-ray study of a recovered dental implant
    • Otulakowska J., and Nicholson J.W. Scanning electron microscopy and energy dispersive X-ray study of a recovered dental implant. Mater Sci Mater Med 17 (2006) 277
    • (2006) Mater Sci Mater Med , vol.17 , pp. 277
    • Otulakowska, J.1    Nicholson, J.W.2
  • 18
    • 85036438739 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis-A two-dimensional comparative study examining the effects of implant diameter, implant shape and load direction
    • Holmgren E.P., Seckinger R.J., Kilgren L.M., et al. Evaluating parameters of osseointegrated dental implants using finite element analysis-A two-dimensional comparative study examining the effects of implant diameter, implant shape and load direction. Oral Implantol 24 (1998) 65
    • (1998) Oral Implantol , vol.24 , pp. 65
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3
  • 19
    • 73949099188 scopus 로고    scopus 로고
    • The effects of implant shapes on stress distribution in implant-bone interface
    • Hongyue L., Zhu L., Zedong L., et al. The effects of implant shapes on stress distribution in implant-bone interface. Chin J Oral Implantol 8 (2003) 61
    • (2003) Chin J Oral Implantol , vol.8 , pp. 61
    • Hongyue, L.1    Zhu, L.2    Zedong, L.3
  • 21
    • 0036730250 scopus 로고    scopus 로고
    • Osteointegration of bioactive glass-coated zirconia in healthy bone: An in vivo evaluation
    • Stanic V., Aldini N.N., Fini M., et al. Osteointegration of bioactive glass-coated zirconia in healthy bone: An in vivo evaluation. Biomaterials 23 (2002) 3833
    • (2002) Biomaterials , vol.23 , pp. 3833
    • Stanic, V.1    Aldini, N.N.2    Fini, M.3
  • 22
    • 1642367181 scopus 로고    scopus 로고
    • Calcium phosphates and glass composite coatings on zirconia for enhanced biocompatibility
    • Kim H.W., Georgiou G., Knowles J.C., et al. Calcium phosphates and glass composite coatings on zirconia for enhanced biocompatibility. Biomaterials 25 (2004) 4203
    • (2004) Biomaterials , vol.25 , pp. 4203
    • Kim, H.W.1    Georgiou, G.2    Knowles, J.C.3
  • 23
    • 0027642518 scopus 로고
    • Apatite formation on three kinds of bioactive material at an early stage in vivo: A comparative study by transmission electron microscopy
    • Neo M., Nakamura T., Ohtsuki C., et al. Apatite formation on three kinds of bioactive material at an early stage in vivo: A comparative study by transmission electron microscopy. J Biomed Mater Res 27 (1993) 999
    • (1993) J Biomed Mater Res , vol.27 , pp. 999
    • Neo, M.1    Nakamura, T.2    Ohtsuki, C.3
  • 24
    • 9744221888 scopus 로고    scopus 로고
    • Constitutive modeling of the densification and the grain growth of hydroxyapatite ceramics
    • He Z., Ma J., and Wang C. Constitutive modeling of the densification and the grain growth of hydroxyapatite ceramics. Biomaterials 26 (2005) 1613
    • (2005) Biomaterials , vol.26 , pp. 1613
    • He, Z.1    Ma, J.2    Wang, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.