메뉴 건너뛰기




Volumn 42, Issue 12, 1997, Pages 342-346

Standardization of zirconia ceramics for total hip replacements;Normung von Zirkonoxidkeramik fur Huftendoprothesen

Author keywords

Bioceramics; Implants; Standardization; Total hip replacement; Zirconia

Indexed keywords

BIOMATERIALS; CERAMIC MATERIALS; CERAMIC PRODUCTS; IMPLANTS (SURGICAL); STANDARDIZATION; ZIRCONIA;

EID: 0031467964     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/bmte.1997.42.12.342     Document Type: Article
Times cited : (15)

References (20)
  • 2
    • 0002876068 scopus 로고    scopus 로고
    • Structural Ceramics in Orthopedics
    • Cameron, H. U. (ed.): Mosby, St. Louis, Baltimore, Boston, Chicago
    • Clarke, I. C., G. Willmann: Structural Ceramics in Orthopedics. In: Cameron, H. U. (ed.): Bone Implant Interface. Mosby, St. Louis, Baltimore, Boston, Chicago, 1994, S 203-252.
    • Bone Implant Interface , vol.1994 , pp. 203-252
    • Clarke, I.C.1    Willmann, G.2
  • 7
    • 0031172868 scopus 로고    scopus 로고
    • Wear Characteristic of Ceramic-on-ceramic for Hip Endoprotheses
    • im Druck
    • Früh, H. J., G. Willmann, H. G. Pfaff: Wear Characteristic of Ceramic-on-ceramic for Hip Endoprotheses. Biomaterials (1997) im Druck
    • (1997) Biomaterials
    • Früh, H.J.1    Willmann, G.2    Pfaff, H.G.3
  • 9
    • 0001291364 scopus 로고
    • Zirconia for Medical Implants - The Role of Strength Properties
    • Andersson, Ö. H. A. Yli-Urpo (eds): Butter-worth-Heinemann Ltd, Oxford
    • Richter, H. G., W. Burger, F. Osthues: Zirconia for Medical Implants - The Role of Strength Properties. In: Andersson, Ö. H. A. Yli-Urpo (eds): Bioceramics 7. Butter-worth-Heinemann Ltd, Oxford, 1994, S. 401-406.
    • (1994) Bioceramics , vol.7 , pp. 401-406
    • Richter, H.G.1    Burger, W.2    Osthues, F.3
  • 10
    • 0025704637 scopus 로고
    • Die Bedeutung der ISO-Norm 6474 für Implantate aus Aluminiumoxid
    • Willmann, G.: Die Bedeutung der ISO-Norm 6474 für Implantate aus Aluminiumoxid. Zahnärztl. Praxis 41 (1990), 286-290.
    • (1990) Zahnärztl. Praxis , vol.41 , pp. 286-290
    • Willmann, G.1
  • 11
    • 0025029814 scopus 로고
    • Normbestimmungen für Hydroxylapatit als Knochenersatz Biomed
    • Willmann. G.: Normbestimmungen für Hydroxylapatit als Knochenersatz Biomed. Technik 35 (1990) 205-207.
    • (1990) Technik , vol.35 , pp. 205-207
    • Willmann, G.1
  • 13
    • 0030298085 scopus 로고    scopus 로고
    • Wear Characterstics of Sliding Pairs of Zirconia (Y-TZP) for Hip Endoprotheses
    • Willmann, G., H. J. Früh, H. G. Pfaff: Wear Characterstics of Sliding Pairs of Zirconia (Y-TZP) for Hip Endoprotheses. Biomaterials 17 (1996) 2157-2162.
    • (1996) Biomaterials , vol.17 , pp. 2157-2162
    • Willmann, G.1    Früh, H.J.2    Pfaff, H.G.3
  • 14
    • 6844261584 scopus 로고    scopus 로고
    • Hydroxyapatite-coating - State-of-the-art Brit
    • im Druck
    • Willmann, G.: Hydroxyapatite-coating - State-of-the-art Brit. Ceram. Trans (1996) im Druck.
    • (1996) Ceram. Trans
    • Willmann, G.1
  • 20
    • 6844239337 scopus 로고    scopus 로고
    • Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal
    • ISO 13356
    • ISO 13356: Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal. zirconia (Y-TZP) 1997.
    • (1997) Zirconia (Y-TZP)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.