메뉴 건너뛰기




Volumn 62, Issue 4, 2005, Pages 1224-1231

An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies

Author keywords

Computed tomography; Metal artifact; Projection interpolation; Prostate; Therapy treatment planning

Indexed keywords

ALGORITHMS; COMPUTERIZED TOMOGRAPHY; INTERPOLATION; PROSTHETICS; REDUCTION; TOXICITY;

EID: 21244471813     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2005.02.052     Document Type: Article
Times cited : (131)

References (21)
  • 1
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • D.D. Robertson, P.J. Weiss, E.K. Fishman Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants J Comput Assist Tomogr 12 1988 236 241
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3
  • 2
    • 0025676560 scopus 로고
    • Reduction of postoperative CT artefacts of pelvic fractures by use of titanium implants
    • N.A. Ebraheim, R. Coombs, J.J. Rusin Reduction of postoperative CT artefacts of pelvic fractures by use of titanium implants Orthopedics 13 1990 1357 1358
    • (1990) Orthopedics , vol.13 , pp. 1357-1358
    • Ebraheim, N.A.1    Coombs, R.2    Rusin, J.J.3
  • 3
    • 0023637829 scopus 로고
    • CT-assisted assessment of bladder and rectum dose in gynecological implants
    • C.C. Ling, M.C. Schell, K.R. Working CT-assisted assessment of bladder and rectum dose in gynecological implants Int J Radiat Oncol Biol Phys 13 1987 1577 1582
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , pp. 1577-1582
    • Ling, C.C.1    Schell, M.C.2    Working, K.R.3
  • 5
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • D.D. Robertson, J. Yuan, G. Wang Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction J Comput Assist Tomogr 21 1997 293 298
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3
  • 6
    • 0031972278 scopus 로고    scopus 로고
    • Iterative reconstruction for helical CT: A simulation study
    • J. Nuyts, B. De Man, P. Dupont Iterative reconstruction for helical CT A simulation study Phys Med Biol 43 1998 729 737
    • (1998) Phys Med Biol , vol.43 , pp. 729-737
    • Nuyts, J.1    De Man, B.2    Dupont, P.3
  • 7
    • 0033431430 scopus 로고    scopus 로고
    • Iterative x-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    • G. Wang, M.W. Vannier, P.C. Cheng Iterative x-ray cone-beam tomography for metal artifact reduction and local region reconstruction Microscopy Microanal 5 1999 58 65
    • (1999) Microscopy Microanal , vol.5 , pp. 58-65
    • Wang, G.1    Vannier, M.W.2    Cheng, P.C.3
  • 8
    • 0030348393 scopus 로고    scopus 로고
    • A very fast implementation of 2D iterative reconstruction algorithms
    • P. Toft A very fast implementation of 2D iterative reconstruction algorithms IEEE Proc Med Imaging Conf 3 1996 1742 1746
    • (1996) IEEE Proc Med Imaging Conf , vol.3 , pp. 1742-1746
    • Toft, P.1
  • 9
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • W.A. Kalender, R. Hebel, J.A. Ebersberger Reduction of CT artifacts caused by metallic implants Radiology 164 1987 576 577
    • (1987) Radiology , vol.164 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.A.3
  • 12
    • 0017955879 scopus 로고
    • Image reconstruction from projections: III. Projection completion methods
    • R.M. Lewitt, R.H.T. Bates Image reconstruction from projections: III. Projection completion methods Optik 50 1978 189 204
    • (1978) Optik , vol.50 , pp. 189-204
    • Lewitt, R.M.1    Bates, R.H.T.2
  • 13
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • S. Zhao, D.D. Robertson, G. Wang X-ray CT metal artifact reduction using wavelets An application for imaging total hip prostheses IEEE Transact Med Imaging 19 2000 1238 1247
    • (2000) IEEE Transact Med Imaging , vol.19 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3
  • 15
    • 0345708391 scopus 로고    scopus 로고
    • A new algorithm for metal artifact reduction in computed tomography: In vitro and in vivo evaluation after total hip replacement
    • A.H. Mahnken, R. Raupach, J.E. Wildberger A new algorithm for metal artifact reduction in computed tomography In vitro and in vivo evaluation after total hip replacement Invest Radiol 38 2003 769 775
    • (2003) Invest Radiol , vol.38 , pp. 769-775
    • Mahnken, A.H.1    Raupach, R.2    Wildberger, J.E.3
  • 17
    • 0002629429 scopus 로고
    • An overview of evolutionary algorithms in multiobjective optimization
    • C.M. Fonseca, P.J. Fleming An overview of evolutionary algorithms in multiobjective optimization Evolution Computat 3 1995 1 16
    • (1995) Evolution Computat , vol.3 , pp. 1-16
    • Fonseca, C.M.1    Fleming, P.J.2
  • 18
  • 20
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63
    • C. Reft, R. Alecu, I.J. Das Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63 Med Phys 30 2003 1162 1182
    • (2003) Med Phys , vol.30 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.J.3
  • 21
    • 5644240930 scopus 로고    scopus 로고
    • Segmentation aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images
    • C. Saint Olive, M.R. Kaus, V. Pekar, K. Eck, L. Spies Segmentation aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images J Med Imaging 5370 2004 1991 2002
    • (2004) J Med Imaging , vol.5370 , pp. 1991-2002
    • Saint Olive, C.1    Kaus, M.R.2    Pekar, V.3    Eck, K.4    Spies, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.