메뉴 건너뛰기




Volumn 16, Issue 1, 2010, Pages 9-15

Correlation of transepidermal water loss with skin barrier properties in vitro: Comparison of three evaporimeters

Author keywords

Evaporimeter; Skin barrier integrity; Transepidermal water loss (TEWL); Tritiated water permeation

Indexed keywords

ABSORBED DOSE; BARRIER PROPERTIES; CLOSED CHAMBERS; DERMATOMED HUMAN SKINS; DIFFUSION CELLS; EVAPORIMETRY; FLOWTHROUGH; FLUX RATES; IN-VITRO; MEASUREMENT CAPACITY; RAPID ASSESSMENT; SKIN PERMEABILITY; SKIN WATER BARRIERS; TRANSEPIDERMAL WATER LOSS; TRANSEPIDERMAL WATER LOSS (TEWL); TRITIATED WATER;

EID: 73549090800     PISSN: 0909752X     EISSN: 16000846     Source Type: Journal    
DOI: 10.1111/j.1600-0846.2009.00406.x     Document Type: Article
Times cited : (55)

References (14)
  • 1
    • 11444268421 scopus 로고    scopus 로고
    • OECD, Paris, France, Organisation for economic co-operation and development (OECD) publishing
    • Skin absorption: in vitro method, Test Guidelines 428 2004, 1-8. OECD, Paris, France, Organisation for economic co-operation and development (OECD) publishing
    • (2004) Skin absorption: in vitro method, Test Guidelines 428 , pp. 1-8
  • 2
    • 13244297586 scopus 로고    scopus 로고
    • Guidance document for the conduct of skin absorption studies number 28
    • OECD, In, Paris, France, Organisation for economic co-operation and development (OECD)
    • Guidance document for the conduct of skin absorption studies number 28. OECD series on testing and assessment 2004, 1-30. OECD, In, Paris, France, Organisation for economic co-operation and development (OECD)
    • (2004) OECD series on testing and assessment , pp. 1-30
  • 3
    • 0032142980 scopus 로고    scopus 로고
    • In vitro measurement of transepidermal water loss: a rapid alternative to tritiated water permeation for assessing skin barrier functions
    • Nangia A, Patil S, Berner B, Boman A, Maibach H. In vitro measurement of transepidermal water loss: a rapid alternative to tritiated water permeation for assessing skin barrier functions. Int J Pharm 1998, 170:33-40.
    • (1998) Int J Pharm , vol.170 , pp. 33-40
    • Nangia, A.1    Patil, S.2    Berner, B.3    Boman, A.4    Maibach, H.5
  • 4
    • 14844331069 scopus 로고    scopus 로고
    • The correlation between transepidermal water loss and percutaneous absorption: an overview
    • Levin J, Maibach H. The correlation between transepidermal water loss and percutaneous absorption: an overview. J Control Release 2005, 103:291-299.
    • (2005) J Control Release , vol.103 , pp. 291-299
    • Levin, J.1    Maibach, H.2
  • 8
    • 0036107340 scopus 로고    scopus 로고
    • A portable device using a closed chamber system for measuring transepidermal water loss: comparison with the conventional method
    • Tagami H, Kobayashi H, Kikuchi K. A portable device using a closed chamber system for measuring transepidermal water loss: comparison with the conventional method. Skin Res Technol 2002, 8:7-12.
    • (2002) Skin Res Technol , vol.8 , pp. 7-12
    • Tagami, H.1    Kobayashi, H.2    Kikuchi, K.3
  • 9
    • 33744801155 scopus 로고    scopus 로고
    • Transepidermal water loss reflects permeability barrier status: validation in human and rodent in vivo and ex vivo models
    • Fluhr JW, Feingold KR, Elias PM. Transepidermal water loss reflects permeability barrier status: validation in human and rodent in vivo and ex vivo models. Exp Dermatol 2006, 15:483-492.
    • (2006) Exp Dermatol , vol.15 , pp. 483-492
    • Fluhr, J.W.1    Feingold, K.R.2    Elias, P.M.3
  • 10
    • 73549116565 scopus 로고    scopus 로고
    • Method and equipment for measuring water vapor flux from surfaces, US Patent 6439028, 2002. (Date of first filing: 1998)
    • Imhof R. 2002, Method and equipment for measuring water vapor flux from surfaces, US Patent 6439028, 2002. (Date of first filing: 1998)
    • (2002)
    • Imhof, R.1
  • 13
    • 61349127266 scopus 로고    scopus 로고
    • Closed-chamber transepidermal water loss measurement: microclimate, calibration and performance
    • Imhof R, De Jesus M, Xiao P, Ciortea L, Berg E. Closed-chamber transepidermal water loss measurement: microclimate, calibration and performance. Int J Cosmet Sci 2009, 31:97-118.
    • (2009) Int J Cosmet Sci , vol.31 , pp. 97-118
    • Imhof, R.1    De Jesus, M.2    Xiao, P.3    Ciortea, L.4    Berg, E.5
  • 14
    • 0022976340 scopus 로고
    • Methods for in vitro percutaneous absorption studies. VII: use of excised human skin
    • Bronaugh RL, Stewart RF, Simon M. Methods for in vitro percutaneous absorption studies. VII: use of excised human skin. J Pharm Sci 1986, 75:1094-1097.
    • (1986) J Pharm Sci , vol.75 , pp. 1094-1097
    • Bronaugh, R.L.1    Stewart, R.F.2    Simon, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.