메뉴 건너뛰기




Volumn 91, Issue 12, 2009, Pages 2970-2982

Surgical treatment of osteoporotic fractures about the knee

Author keywords

[No Author keywords available]

Indexed keywords

BONE PLATE; COMORBIDITY; CONFERENCE PAPER; EVALUATION; FEMUR FRACTURE; FRACTURE FIXATION; FRAGILITY FRACTURE; HUMAN; IMPLANT; INTRAMEDULLARY NAILING; JOINT SURGERY; KNEE; OSTEOARTHRITIS; OSTEOSYNTHESIS; PATIENT POSITIONING; PLANNING; POSTOPERATIVE CARE; PRIORITY JOURNAL; RISK REDUCTION; SURGICAL TECHNIQUE; TIBIA FRACTURE; TOTAL KNEE REPLACEMENT; WOUND CLOSURE; ARTICLE; CLASSIFICATION; INTRAARTICULAR FRACTURE; KNEE INJURY; ORTHOPEDIC EQUIPMENT; OSTEOPOROSIS; PATHOLOGIC FRACTURE;

EID: 73349089340     PISSN: 00219355     EISSN: 15351386     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (17)
  • 2
    • 0036713403 scopus 로고    scopus 로고
    • High-energy fractures of the tibial plateau. Knee function after longer follow-up
    • Weigel DP, Marsh JL. High-energy fractures of the tibial plateau. Knee function after longer follow-up. J Bone Joint Surg Am. 2002;84:1541-51.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1541-1551
    • Weigel, D.P.1    Marsh, J.L.2
  • 3
    • 4644224564 scopus 로고    scopus 로고
    • Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures
    • Zlowodzki M, Williamson S, Cole PA, Zardiackas LD, Kregor PJ. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma. 2004;18: 494-502.
    • (2004) J Orthop Trauma , vol.18 , pp. 494-502
    • Zlowodzki, M.1    Williamson, S.2    Cole, P.A.3    Zardiackas, L.D.4    Kregor, P.J.5
  • 4
    • 34248232008 scopus 로고    scopus 로고
    • Biomechanical analysis of bicondylar tibial plateau fixation: How does lateral locking plate fixation compare to dual plate fixation?
    • Higgins TF, Klatt J, Bachus KN. Biomechanical analysis of bicondylar tibial plateau fixation: how does lateral locking plate fixation compare to dual plate fixation? J Orthop Trauma. 2007;21:301-6.
    • (2007) J Orthop Trauma , vol.21 , pp. 301-306
    • Higgins, T.F.1    Klatt, J.2    Bachus, K.N.3
  • 5
    • 0031252449 scopus 로고    scopus 로고
    • Distal femoral fixation: A biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate
    • Koval KJ, Hoehl JJ, Kummer FJ, Simon JA. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. J Orthop Trauma. 1997;11:521-4.
    • (1997) J Orthop Trauma , vol.11 , pp. 521-524
    • Koval, K.J.1    Hoehl, J.J.2    Kummer, F.J.3    Simon, J.A.4
  • 7
    • 0032432390 scopus 로고    scopus 로고
    • The retrograde intramedullary supracondylar nail: An alternative in the treatment of distal femoral fractures in the elderly?
    • Janzing HM, Stockman B, Van Damme G, Rommens P, Broos PL. The retrograde intramedullary supracondylar nail: an alternative in the treatment of distal femoral fractures in the elderly? Arch Orthop Trauma Surg. 1998;118:92-5.
    • (1998) Arch Orthop Trauma Surg , vol.118 , pp. 92-95
    • Janzing, H.M.1    Stockman, B.2    Van Damme, G.3    Rommens, P.4    Broos, P.L.5
  • 9
    • 0036198119 scopus 로고    scopus 로고
    • Minimal versus maximal plate fixation techniques of the ulna: The biomechanical effect of number of screws and plate length
    • Sanders R, Haidukewych GJ, Milne T, Dennis J, Latta LL. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. J Orthop Trauma. 2002;16:166-71.
    • (2002) J Orthop Trauma , vol.16 , pp. 166-171
    • Sanders, R.1    Haidukewych, G.J.2    Milne, T.3    Dennis, J.4    Latta, L.L.5
  • 10
    • 40349103973 scopus 로고    scopus 로고
    • Results of polyaxial locked-plate fixation of periarticular fractures of the knee
    • DOI 10.2106/JBJS.G.01086
    • Haidukewych G, Sems SA, Huebner D, Horwitz D, Levy B. Results of polyaxial locked-plate fixation of periarticular fractures of the knee. Surgical technique. J Bone Joint Surg Am. 2008;90 Suppl 2(Pt 1):117-34. (Pubitemid 351341975)
    • (2008) Journal of Bone and Joint Surgery - Series a , vol.90 , Issue.SUPPL. 2 PART 1 , pp. 117-134
    • Haidukewych, G.1    Sems, S.A.2    Huebner, D.3    Horwitz, D.4    Levy, B.5
  • 11
    • 0018750026 scopus 로고
    • The tibial plateau fracture. The Toronto experience 1968-1975
    • Schatzker J, McBroom R, Bruce D. The tibial plateau fracture. The Toronto experience 1968-1975. Clin Orthop Relat Res. 1979;138:94-104.
    • (1979) Clin Orthop Relat Res , vol.138 , pp. 94-104
    • Schatzker, J.1    McBroom, R.2    Bruce, D.3
  • 13
    • 0036195247 scopus 로고    scopus 로고
    • Use of an injectable calcium phosphate bone cement in the treatment of tibial plateau fractures: A prospective study of twenty-six cases with twenty-month mean follow-up
    • Lobenhoffer P, Gerich T, Witte F, Tscherne H. Use of an injectable calcium phosphate bone cement in the treatment of tibial plateau fractures: a prospective study of twenty-six cases with twenty-month mean follow-up. J Orthop Trauma. 2002;16: 143-9.
    • (2002) J Orthop Trauma , vol.16 , pp. 143-149
    • Lobenhoffer, P.1    Gerich, T.2    Witte, F.3    Tscherne, H.4
  • 14
    • 53549124132 scopus 로고    scopus 로고
    • Comparison of autogenous bone graft and endothermic calcium phosphate cement for defect augmentation in tibial plateau fractures. A multicenter, prospective, randomized study
    • Alpha-BSM Tibial Plateau Fracture Study Group
    • Russell TA, Leighton RK; Alpha-BSM Tibial Plateau Fracture Study Group. Comparison of autogenous bone graft and endothermic calcium phosphate cement for defect augmentation in tibial plateau fractures. A multicenter, prospective, randomized study. J Bone Joint Surg Am. 2008;90: 2057-61.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2057-2061
    • Russell, T.A.1    Leighton, R.K.2
  • 15
    • 0035727105 scopus 로고    scopus 로고
    • The effect of screw type on the fixation of depressed fragments in tibial plateau fractures
    • Cooper HJ, Kummer FJ, Egol KA, Koval KJ. The effect of screw type on the fixation of depressed fragments in tibial plateau fractures. Bull Hosp Jt Dis. 2001-2002;60:72-5.
    • (2001) Bull Hosp Jt Dis , vol.60 , pp. 72-75
    • Cooper, H.J.1    Kummer, F.J.2    Egol, K.A.3    Koval, K.J.4
  • 16
    • 33746166427 scopus 로고    scopus 로고
    • A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures
    • Patil S, Mahon A, Green S, McMurtry I, Port A. A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures. Knee. 2006;13:231-5.
    • (2006) Knee , vol.13 , pp. 231-235
    • Patil, S.1    Mahon, A.2    Green, S.3    McMurtry, I.4    Port, A.5
  • 17
    • 43249125182 scopus 로고    scopus 로고
    • Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns
    • Barei DP, O'Mara TJ, Taitsman LA, Dunbar RP, Nork SE. Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns. J Orthop Trauma. 2008;22: 176-82.
    • (2008) J Orthop Trauma , vol.22 , pp. 176-182
    • Barei, D.P.1    O'Mara, T.J.2    Taitsman, L.A.3    Dunbar, R.P.4    Nork, S.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.