메뉴 건너뛰기




Volumn 11, Issue 7, 1997, Pages 521-524

Distal femoral fixation: A biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate

Author keywords

Biomechanical; Distal femur; Fracture fixation

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; BIOMECHANICS; BONE PLATE; CADAVER; COMPARATIVE STUDY; EQUIPMENT DESIGN; FEMUR FRACTURE; FRACTURE FIXATION; HUMAN; IN VITRO STUDY; INSTRUMENTATION; JOINT INSTABILITY; METHODOLOGY; RANDOMIZATION; REFERENCE VALUE; WEIGHT BEARING;

EID: 0031252449     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-199710000-00010     Document Type: Article
Times cited : (142)

References (6)
  • 1
    • 0023869835 scopus 로고
    • Telemetric force measurements across the hip after total arthroplasty
    • Davy DT, Kotzar GM, Brown RH, et al. Telemetric force measurements across the hip after total arthroplasty. J Bone Joint Surg 1988;70A:45-50.
    • (1988) J Bone Joint Surg , vol.70 A , pp. 45-50
    • Davy, D.T.1    Kotzar, G.M.2    Brown, R.H.3
  • 3
    • 0029681762 scopus 로고    scopus 로고
    • Distal femoral fixation: A laboratory comparison of the 95° plate, antegrade and retrograde inserted reamed intramedullary nails
    • Koval KJ, Kummer FJ, Bharam S, Chen D, Halder S. Distal femoral fixation: a laboratory comparison of the 95° plate, antegrade and retrograde inserted reamed intramedullary nails. J Orthop Trauma 1996;10:378-382.
    • (1996) J Orthop Trauma , vol.10 , pp. 378-382
    • Koval, K.J.1    Kummer, F.J.2    Bharam, S.3    Chen, D.4    Halder, S.5
  • 4
    • 0029683183 scopus 로고    scopus 로고
    • The use of endosteal substitution in the treatment of recalcitrant nonunions of the femur: Report of seven cases
    • Matelic TM, Monroe MT, Mast JW. The use of endosteal substitution in the treatment of recalcitrant nonunions of the femur: report of seven cases. J Orthop Trauma 1996;10:1-6.
    • (1996) J Orthop Trauma , vol.10 , pp. 1-6
    • Matelic, T.M.1    Monroe, M.T.2    Mast, J.W.3
  • 5
    • 0024372582 scopus 로고
    • Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw
    • Sanders R, Regazzoni P, Ruedi T. Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma 1989;3:214-222.
    • (1989) J Orthop Trauma , vol.3 , pp. 214-222
    • Sanders, R.1    Regazzoni, P.2    Ruedi, T.3
  • 6
    • 0026318617 scopus 로고
    • Double-plating of comminuted, unstable fractures of the distal part of the femur
    • Sanders R, Swiontkowski M, Rosen H, Helfet D. Double-plating of comminuted, unstable fractures of the distal part of the femur. J Bone Joint Surg 1991;3:341-346.
    • (1991) J Bone Joint Surg , vol.3 , pp. 341-346
    • Sanders, R.1    Swiontkowski, M.2    Rosen, H.3    Helfet, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.