-
2
-
-
44449159912
-
Developments in coronary CT angiography
-
Achenbach S. Developments in coronary CT angiography. Curr Cardiol Rep 10 (2008) 51-59
-
(2008)
Curr Cardiol Rep
, vol.10
, pp. 51-59
-
-
Achenbach, S.1
-
3
-
-
21044437340
-
Noninvasive coronary angiography with multislice computed tomography
-
Hoffmann M.H., Shi H., Schmitz B.L., et al. Noninvasive coronary angiography with multislice computed tomography. JAMA 293 (2005) 2471-2478
-
(2005)
JAMA
, vol.293
, pp. 2471-2478
-
-
Hoffmann, M.H.1
Shi, H.2
Schmitz, B.L.3
-
4
-
-
33846984653
-
Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients
-
Muhlenbruch G., Seyfarth T., Soo C.S., et al. Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients. Eur Radiol 17 (2007) 603-609
-
(2007)
Eur Radiol
, vol.17
, pp. 603-609
-
-
Muhlenbruch, G.1
Seyfarth, T.2
Soo, C.S.3
-
5
-
-
40049091666
-
Comparison of sensitivity, specificity, positive predictive value, and negative predictive value of stress testing versus 64-multislice coronary computed tomography angiography in predicting obstructive coronary artery disease diagnosed by coronary angiography
-
Ravipati G., Aronow W.S., Lai H., et al. Comparison of sensitivity, specificity, positive predictive value, and negative predictive value of stress testing versus 64-multislice coronary computed tomography angiography in predicting obstructive coronary artery disease diagnosed by coronary angiography. Am J Cardiol 101 (2008) 774-775
-
(2008)
Am J Cardiol
, vol.101
, pp. 774-775
-
-
Ravipati, G.1
Aronow, W.S.2
Lai, H.3
-
6
-
-
47349090039
-
Coronary computed tomography angiography as a screening tool for the detection of occult coronary artery disease in asymptomatic individuals
-
Choi E.K., Choi S.I., Rivera J.J., et al. Coronary computed tomography angiography as a screening tool for the detection of occult coronary artery disease in asymptomatic individuals. J Am Coll Cardiol 52 (2008) 357-365
-
(2008)
J Am Coll Cardiol
, vol.52
, pp. 357-365
-
-
Choi, E.K.1
Choi, S.I.2
Rivera, J.J.3
-
7
-
-
34247138034
-
Noninvasive coronary angiography using 64-detector-row computed tomography in patients with a low to moderate pretest probability of significant coronary artery disease
-
Schlosser T., Mohrs O.K., Magedanz A., et al. Noninvasive coronary angiography using 64-detector-row computed tomography in patients with a low to moderate pretest probability of significant coronary artery disease. Acta Radiol 48 (2007) 300-307
-
(2007)
Acta Radiol
, vol.48
, pp. 300-307
-
-
Schlosser, T.1
Mohrs, O.K.2
Magedanz, A.3
-
8
-
-
58149377814
-
Cardiac dual-source computed tomography: effect of body mass index on image quality and diagnostic accuracy
-
Brodoefel H., Tsiflikas I., Burgstahler C., et al. Cardiac dual-source computed tomography: effect of body mass index on image quality and diagnostic accuracy. Invest Radiol 43 (2008) 712-718
-
(2008)
Invest Radiol
, vol.43
, pp. 712-718
-
-
Brodoefel, H.1
Tsiflikas, I.2
Burgstahler, C.3
-
9
-
-
41149178750
-
Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography
-
Shapiro M.D., Pena A.J., Nichols J.H., et al. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography. Eur J Radiol 66 (2008) 37-41
-
(2008)
Eur J Radiol
, vol.66
, pp. 37-41
-
-
Shapiro, M.D.1
Pena, A.J.2
Nichols, J.H.3
-
10
-
-
34848884199
-
64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease
-
Meijboom W.B., van Mieghem C.A., Mollet N.R., et al. 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol 50 (2007) 1469-1475
-
(2007)
J Am Coll Cardiol
, vol.50
, pp. 1469-1475
-
-
Meijboom, W.B.1
van Mieghem, C.A.2
Mollet, N.R.3
-
11
-
-
59249097545
-
Improved noninvasive coronary angiography in morbidly obese patients with dual-source computed tomography
-
Chinnaiyan K.M., McCullough P.A., Flohr T.G., et al. Improved noninvasive coronary angiography in morbidly obese patients with dual-source computed tomography. J Cardiovasc Comput Tomogr 3 (2009) 35-42
-
(2009)
J Cardiovasc Comput Tomogr
, vol.3
, pp. 35-42
-
-
Chinnaiyan, K.M.1
McCullough, P.A.2
Flohr, T.G.3
-
12
-
-
59449092551
-
Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography
-
Rixe J., Rolf A., Conradi G., et al. Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography. Circ J 73 (2009) 316-322
-
(2009)
Circ J
, vol.73
, pp. 316-322
-
-
Rixe, J.1
Rolf, A.2
Conradi, G.3
-
13
-
-
41149084470
-
Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
-
Alkadhi H., Scheffel H., Desbiolles L., et al. Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. Eur Heart J 29 (2008) 766-776
-
(2008)
Eur Heart J
, vol.29
, pp. 766-776
-
-
Alkadhi, H.1
Scheffel, H.2
Desbiolles, L.3
-
14
-
-
37449003958
-
Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
-
Ropers U., Ropers D., Pflederer T., et al. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 50 (2007) 2393-2398
-
(2007)
J Am Coll Cardiol
, vol.50
, pp. 2393-2398
-
-
Ropers, U.1
Ropers, D.2
Pflederer, T.3
-
15
-
-
34547792220
-
Reliable high-speed coronary computed tomography in symptomatic patients
-
Weustink A.C., Meijboom W.B., Mollet N.R., et al. Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 50 (2007) 786-794
-
(2007)
J Am Coll Cardiol
, vol.50
, pp. 786-794
-
-
Weustink, A.C.1
Meijboom, W.B.2
Mollet, N.R.3
-
16
-
-
59949099102
-
Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography
-
Burgstahler C., Reimann A., Brodoefel H., et al. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography. Eur Radiol 19 (2009) 584-590
-
(2009)
Eur Radiol
, vol.19
, pp. 584-590
-
-
Burgstahler, C.1
Reimann, A.2
Brodoefel, H.3
-
17
-
-
33846635526
-
A pretest prognostic score to assess patients undergoing exercise or pharmacological stress testing
-
Morise A., Evans M., Jalisi F., et al. A pretest prognostic score to assess patients undergoing exercise or pharmacological stress testing. Heart 93 (2007) 200-204
-
(2007)
Heart
, vol.93
, pp. 200-204
-
-
Morise, A.1
Evans, M.2
Jalisi, F.3
-
18
-
-
0041375474
-
Evaluation of pretest and exercise test scores to assess all-cause mortality in unselected patients presenting for exercise testing with symptoms of suspected coronary artery disease
-
Morise A.P., and Jalisi F. Evaluation of pretest and exercise test scores to assess all-cause mortality in unselected patients presenting for exercise testing with symptoms of suspected coronary artery disease. J Am Coll Cardiol 42 (2003) 842-850
-
(2003)
J Am Coll Cardiol
, vol.42
, pp. 842-850
-
-
Morise, A.P.1
Jalisi, F.2
-
19
-
-
11144247393
-
Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution
-
Kuettner A., Beck T., Drosch T., et al. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45 (2005) 123-127
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 123-127
-
-
Kuettner, A.1
Beck, T.2
Drosch, T.3
-
20
-
-
35148867562
-
Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
-
Leber A.W., Johnson T., Becker A., et al. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 28 (2007) 2354-2360
-
(2007)
Eur Heart J
, vol.28
, pp. 2354-2360
-
-
Leber, A.W.1
Johnson, T.2
Becker, A.3
-
21
-
-
22844448174
-
Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
-
Raff G.L., Gallagher M.J., O'Neill W.W., et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46 (2005) 552-557
-
(2005)
J Am Coll Cardiol
, vol.46
, pp. 552-557
-
-
Raff, G.L.1
Gallagher, M.J.2
O'Neill, W.W.3
-
22
-
-
38449089116
-
Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
-
Johnson T.R., Nikolaou K., Busch S., et al. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol 42 (2007) 684-691
-
(2007)
Invest Radiol
, vol.42
, pp. 684-691
-
-
Johnson, T.R.1
Nikolaou, K.2
Busch, S.3
-
23
-
-
26844549564
-
High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography
-
Mollet N.R., Cademartiri F., van Mieghem C.A., et al. High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112 (2005) 2318-2323
-
(2005)
Circulation
, vol.112
, pp. 2318-2323
-
-
Mollet, N.R.1
Cademartiri, F.2
van Mieghem, C.A.3
-
24
-
-
33744967019
-
Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification
-
e1321-1326
-
Ong T.K., Chin S.P., Liew C.K., et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 151 (2006) 1323 e1321-1326
-
(2006)
Am Heart J
, vol.151
, pp. 1323
-
-
Ong, T.K.1
Chin, S.P.2
Liew, C.K.3
-
25
-
-
39349101981
-
Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
-
Schroeder S., Achenbach S., Bengel F., et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology. Eur Heart J 29 (2008) 531-556
-
(2008)
Eur Heart J
, vol.29
, pp. 531-556
-
-
Schroeder, S.1
Achenbach, S.2
Bengel, F.3
-
26
-
-
33947399137
-
Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
-
Scheffel H., Alkadhi H., Plass A., et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16 (2006) 2739-2747
-
(2006)
Eur Radiol
, vol.16
, pp. 2739-2747
-
-
Scheffel, H.1
Alkadhi, H.2
Plass, A.3
|