메뉴 건너뛰기




Volumn 46, Issue 4, 2009, Pages 305-311

Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: A three-year follow-up of 37 patients

Author keywords

Lumbar stenosis; Osteoporosis; Pedicle screw; PMMA

Indexed keywords

POLY(METHYL METHACRYLATE);

EID: 73049106360     PISSN: 20053711     EISSN: 15987876     Source Type: Journal    
DOI: 10.3340/jkns.2009.46.4.305     Document Type: Article
Times cited : (86)

References (47)
  • 1
    • 0034773733 scopus 로고    scopus 로고
    • Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures
    • discussion 1114-1115
    • Amar AP, Larsen DW, Esnaashari N, Albuquerque FC, Lavine SD, Teitelbaum GP : Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures. Neurosurgery 49 : 1105-1114; discussion 1114-1115, 2001
    • (2001) Neurosurgery , vol.49 , pp. 1105-1114
    • Amar, A.P.1    Larsen, D.W.2    Esnaashari, N.3    Albuquerque, F.C.4    Lavine, S.D.5    Teitelbaum, G.P.6
  • 4
    • 7944237760 scopus 로고    scopus 로고
    • Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty
    • Choe DH, Marom EM, Ahrar K, Truong MT, Madewell JE : Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty. AJR Am J Roentgenol 183 : 1097-1102, 2004
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1097-1102
    • Choe, D.H.1    Marom, E.M.2    Ahrar, K.3    Truong, M.T.4    Madewell, J.E.5
  • 5
    • 0042919361 scopus 로고    scopus 로고
    • Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS 3rd : Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation and osteoporosis. Spine J 1 : 109-114, 2001
    • Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS 3rd : Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation and osteoporosis. Spine J 1 : 109-114, 2001
  • 6
    • 3342928907 scopus 로고    scopus 로고
    • Biomechanical study of pedicle screw fixation in severely osteoporotic bone
    • Cook SD, Salkeld SL, Stanley T, Faciane A, Miller SD : Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4 : 402-408, 2004
    • (2004) Spine J , vol.4 , pp. 402-408
    • Cook, S.D.1    Salkeld, S.L.2    Stanley, T.3    Faciane, A.4    Miller, S.D.5
  • 7
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures : An open prospective study
    • Cortet B, Cotten A, Boutry N, Flipo RM, Duquesnoy B, Chastanet P, et al. : Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures : An open prospective study. J Rheumatol 26 : 2222-2228, 1999
    • (1999) J Rheumatol , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3    Flipo, R.M.4    Duquesnoy, B.5    Chastanet, P.6
  • 8
    • 11244328115 scopus 로고    scopus 로고
    • Posterolateral versus interbody fusion in isthmic spondylolisthesis : Functional results in 52 cases with a minimum follow-up of 6 years
    • Dehoux E, Fourati E, Madi K, Reddy B, Segal P : Posterolateral versus interbody fusion in isthmic spondylolisthesis : functional results in 52 cases with a minimum follow-up of 6 years. Acta Orthop Belg 70 : 578-582, 2004
    • (2004) Acta Orthop Belg , vol.70 , pp. 578-582
    • Dehoux, E.1    Fourati, E.2    Madi, K.3    Reddy, B.4    Segal, P.5
  • 9
    • 0027484342 scopus 로고    scopus 로고
    • Esses SI, Sachs BL, Dreyzin V : Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18 : 2231-2238; discussion 2238-2239, 1993
    • Esses SI, Sachs BL, Dreyzin V : Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18 : 2231-2238; discussion 2238-2239, 1993
  • 10
    • 0029294443 scopus 로고
    • Pullout strength of fixation screws from polymethylmethacrylate bone cement
    • Flahiff CM, Gober GA, Nicholas RW : Pullout strength of fixation screws from polymethylmethacrylate bone cement. Biomaterials 16 : 533-536, 1995
    • (1995) Biomaterials , vol.16 , pp. 533-536
    • Flahiff, C.M.1    Gober, G.A.2    Nicholas, R.W.3
  • 11
    • 33846860406 scopus 로고    scopus 로고
    • Is one cage enough in posterior lumbar interbody fusion : A comparison of unilateral single cage interbody fusion to bilateral cages
    • Fogel GR, Toohey JS, Neidre A, Brantigan JW : Is one cage enough in posterior lumbar interbody fusion : a comparison of unilateral single cage interbody fusion to bilateral cages. J Spinal Disord Tech 20 : 60-65, 2007
    • (2007) J Spinal Disord Tech , vol.20 , pp. 60-65
    • Fogel, G.R.1    Toohey, J.S.2    Neidre, A.3    Brantigan, J.W.4
  • 12
    • 34447578691 scopus 로고    scopus 로고
    • A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation
    • Frankel BM, D'Agostino S, Wang C : A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation. J Neurosurg Spine 7 : 47-53, 2007
    • (2007) J Neurosurg Spine , vol.7 , pp. 47-53
    • Frankel, B.M.1    D'Agostino, S.2    Wang, C.3
  • 13
    • 34548823221 scopus 로고    scopus 로고
    • Segmental polymethylmethacrylateaugmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement : A clinical evaluation
    • discussion 537-538
    • Frankel BM, Jones T, Wang C : Segmental polymethylmethacrylateaugmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement : a clinical evaluation. Neurosurgery 61 : 531-537; discussion 537-538, 2007
    • (2007) Neurosurgery , vol.61 , pp. 531-537
    • Frankel, B.M.1    Jones, T.2    Wang, C.3
  • 14
    • 34748828574 scopus 로고    scopus 로고
    • Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases
    • Fransen P : Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases. J Neurosurg Spine 7 : 366-369, 2007
    • (2007) J Neurosurg Spine , vol.7 , pp. 366-369
    • Fransen, P.1
  • 15
  • 16
    • 0029757357 scopus 로고    scopus 로고
    • Rib graft or cement to enhance screw fixation in anterior vertebral bodies
    • Hernigou P, Duparc F : Rib graft or cement to enhance screw fixation in anterior vertebral bodies. J Spinal Disord 9 : 322-325, 1996
    • (1996) J Spinal Disord , vol.9 , pp. 322-325
    • Hernigou, P.1    Duparc, F.2
  • 17
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures : Technical aspects
    • Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE : Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures : Technical aspects. AJNR Am J Neuroradiol 18 : 1897-1904, 1997
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3    Kallmes, D.F.4    Cloft, H.J.5    Dion, J.E.6
  • 19
    • 0022653406 scopus 로고
    • Techniques of internal fixation for degenerative conditions of the lumbar spine
    • Kostuik JP, Errico TJ, Gleason TF : Techniques of internal fixation for degenerative conditions of the lumbar spine. Clin Orthop Relat Res : 219-231, 1986
    • (1986) Clin Orthop Relat Res , vol.219-231
    • Kostuik, J.P.1    Errico, T.J.2    Gleason, T.F.3
  • 21
    • 0345741420 scopus 로고    scopus 로고
    • Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion
    • Madan SS, Boeree NR : Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion. Eur Spine J 12 : 567-575, 2003
    • (2003) Eur Spine J , vol.12 , pp. 567-575
    • Madan, S.S.1    Boeree, N.R.2
  • 22
    • 0034043772 scopus 로고    scopus 로고
    • An injectable cementing screw for fixation in osteoporotic bone
    • McKoy BE, An YH : An injectable cementing screw for fixation in osteoporotic bone. J Biomed Mater Res 53 : 216-220, 2000
    • (2000) J Biomed Mater Res , vol.53 , pp. 216-220
    • McKoy, B.E.1    An, Y.H.2
  • 23
    • 6644226483 scopus 로고    scopus 로고
    • Influence of bone mineral density on pedicle screw fixation : A study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients
    • Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K : Influence of bone mineral density on pedicle screw fixation : A study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J 1 : 402-407, 2001
    • (2001) Spine J , vol.1 , pp. 402-407
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3    Tamura, Y.4    Chiba, M.5    Sato, K.6
  • 24
    • 33846883240 scopus 로고    scopus 로고
    • PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis- in augmentation with a pedicle screw
    • Okuyama K, Kido T, Unoki E, Chiba M : PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis- in augmentation with a pedicle screw. J Spinal Disord Tech 20 : 53-59, 2007
    • (2007) J Spinal Disord Tech , vol.20 , pp. 53-59
    • Okuyama, K.1    Kido, T.2    Unoki, E.3    Chiba, M.4
  • 25
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability
    • Okuyama K, Sato K, Abe E, Inaba H, Shimada Y, Murai H : Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine (Phila Pa 1976) 18 : 2240-2245, 1993
    • (1993) Spine (Phila Pa 1976) 18 , pp. 2240-2245
    • Okuyama, K.1    Sato, K.2    Abe, E.3    Inaba, H.4    Shimada, Y.5    Murai, H.6
  • 27
    • 0036211378 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures
    • Peh WC, Gilula LA, Peck DD : Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures. Radiology 223 : 121-126, 2002
    • (2002) Radiology , vol.223 , pp. 121-126
    • Peh, W.C.1    Gilula, L.A.2    Peck, D.D.3
  • 29
    • 0028314201 scopus 로고
    • Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
    • Pfeifer BA, Krag MH, Johnson C : Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine (Phila Pa 1976) 19 : 350-353, 1994
    • (1994) Spine (Phila Pa 1976) 19 , pp. 350-353
    • Pfeifer, B.A.1    Krag, M.H.2    Johnson, C.3
  • 30
    • 0022452972 scopus 로고
    • Toward uniformity in evaluating results of lumbar spine operations. A paradigm applied to posterior lumbar interbody fusions
    • Prolo DJ, Oklund SA, Butcher M : Toward uniformity in evaluating results of lumbar spine operations. A paradigm applied to posterior lumbar interbody fusions. Spine (Phila Pa 1976) 11 : 601-606, 1986
    • (1986) Spine (Phila Pa 1976) 11 , pp. 601-606
    • Prolo, D.J.1    Oklund, S.A.2    Butcher, M.3
  • 32
    • 0036121313 scopus 로고    scopus 로고
    • Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures
    • Ryu KS, Park CK, Kim MC, Kang JK : Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96 : 56-61, 2002
    • (2002) J Neurosurg , vol.96 , pp. 56-61
    • Ryu, K.S.1    Park, C.K.2    Kim, M.C.3    Kang, J.K.4
  • 33
    • 0036128620 scopus 로고    scopus 로고
    • Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines
    • Sarzier JS, Evans AJ, Cahill DW : Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg 96 : 309-312, 2002
    • (2002) J Neurosurg , vol.96 , pp. 309-312
    • Sarzier, J.S.1    Evans, A.J.2    Cahill, D.W.3
  • 35
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Kondo H, Murota K : An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine (Phila Pa 1976) 16 : 1335-1341, 1991
    • (1991) Spine (Phila Pa 1976) 16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3    Murota, K.4
  • 36
    • 0022642420 scopus 로고
    • Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine
    • Steffee AD, Biscup RS, Sitkowski DJ : Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Relat Res : 45-53, 1986
    • (1986) Clin Orthop Relat Res , vol.45-53
    • Steffee, A.D.1    Biscup, R.S.2    Sitkowski, D.J.3
  • 37
    • 34548394072 scopus 로고    scopus 로고
    • Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement
    • Takigawa T, Tanaka M, Konishi H, Ikuma H, Misawa H, Sugimoto Y, et al. : Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement. J Spinal Disord Tech 20 : 462-467, 2007
    • (2007) J Spinal Disord Tech , vol.20 , pp. 462-467
    • Takigawa, T.1    Tanaka, M.2    Konishi, H.3    Ikuma, H.4    Misawa, H.5    Sugimoto, Y.6
  • 38
    • 33750107862 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion (PLIF) with cages and local bone graft in the treatment of spinal stenosis
    • Trouillier H, Birkenmaier C, Rauch A, Weiler C, Kauschke T, Refior HJ : Posterior lumbar interbody fusion (PLIF) with cages and local bone graft in the treatment of spinal stenosis. Acta Orthop Belg 72 : 460-466, 2006
    • (2006) Acta Orthop Belg , vol.72 , pp. 460-466
    • Trouillier, H.1    Birkenmaier, C.2    Rauch, A.3    Weiler, C.4    Kauschke, T.5    Refior, H.J.6
  • 39
    • 0016568465 scopus 로고
    • Acrylic cement stabilized joint replacements
    • Urist MR : Acrylic cement stabilized joint replacements. Curr Probl Surg : 1-54, 1975
    • (1975) Curr Probl Surg , vol.1-54
    • Urist, M.R.1
  • 40
    • 0033011007 scopus 로고    scopus 로고
    • Surgically controlled, transpedicular methyl methacrylate vertebroplasty with fluoroscopic guidance
    • Wenger M, Markwalder TM : Surgically controlled, transpedicular methyl methacrylate vertebroplasty with fluoroscopic guidance. Acta Neurochir (Wien) 141 : 625-631, 1999
    • (1999) Acta Neurochir (Wien) , vol.141 , pp. 625-631
    • Wenger, M.1    Markwalder, T.M.2
  • 41
    • 0028012866 scopus 로고
    • Neurological deterioration after cement injection into a vertebral body
    • Wilkes RA, Mackinnon JG, Thomas WG : Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 76 : 155, 1994
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 155
    • Wilkes, R.A.1    Mackinnon, J.G.2    Thomas, W.G.3
  • 42
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • Wittenberg RH, Lee KS, Shea M, White AA 3rd, Hayes WC : Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res : 278-287, 1993
    • (1993) Clin Orthop Relat Res , vol.278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3    White 3rd, A.A.4    Hayes, W.C.5
  • 44
    • 0034528813 scopus 로고    scopus 로고
    • Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities : An innovative technique
    • Wuisman PI, Van Dijk M, Staal H, Van Royen BJ : Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities : An innovative technique. Eur Spine J 9 : 528-533, 2000
    • (2000) Eur Spine J , vol.9 , pp. 528-533
    • Wuisman, P.I.1    Van Dijk, M.2    Staal, H.3    Van Royen, B.J.4
  • 45
    • 13244279612 scopus 로고    scopus 로고
    • Efficacy of novelconcept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine
    • Yazu M, Kin A, Kosaka R, Kinoshita M, Abe M : Efficacy of novelconcept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine. J Orthop Sci 10 : 56-61, 2005
    • (2005) J Orthop Sci , vol.10 , pp. 56-61
    • Yazu, M.1    Kin, A.2    Kosaka, R.3    Kinoshita, M.4    Abe, M.5
  • 46
    • 5444261977 scopus 로고    scopus 로고
    • Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylate
    • Yoo KY, Jeong SW, Yoon W, Lee J : Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylate. Spine (Phila Pa 1976) 29 : E294-297, 2004
    • (2004) Spine (Phila Pa 1976) 29
    • Yoo, K.Y.1    Jeong, S.W.2    Yoon, W.3    Lee, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.