Volumn 10, Issue 1, 2005, Pages 56-61

Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine

Author keywords

Biomechanics; Calcium phosphate cement; Osteoporosis; Pedicle screw; Spine

Indexed keywords

CALCIUM PHOSPHATE;

EID: 13244279612     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-004-0862-8     Document Type: Article
Times cited : (63)

References (26)
  • 1
    • 0031413425 scopus 로고    scopus 로고
    • An experimental study of lumbar destabilization: Restabilization and bone density
    • Bennett GJ, Serhan HA, Sorini PM, et al. An experimental study of lumbar destabilization: restabilization and bone density. Spine 1997;22:1448-53.
    • (1997) Spine , vol.22 , pp. 1448-1453
    • Bennett, G.J.1    Serhan, H.A.2    Sorini, P.M.3
  • 2
    • 0027959952 scopus 로고
    • The effects of pedicle screw fit: An in vitro study
    • Brantley AGU, Mayfield JK, Koeneman JB, et al. The effects of pedicle screw fit: An in vitro study. Spine 1994;19:1752-8.
    • (1994) Spine , vol.19 , pp. 1752-1758
    • Brantley, A.G.U.1    Mayfield, J.K.2    Koeneman, J.B.3
  • 3
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thoracolumbar implants: A comparative study of transpedicular screws, laminar hooks, and spinous process wires
    • Coe JD, Warden KE, Herzig MA, et al. Influence of bone mineral density on the fixation of thoracolumbar implants: a comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 1990;15:902-7.
    • (1990) Spine , vol.15 , pp. 902-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3
  • 4
    • 0028222776 scopus 로고
    • Formalin fixation effects on vertebral bone density and failure mechanics: An in-vitro study of human and sheep vertebrae
    • Edmondston SJ, Singer KP, Day RE, et al. Formalin fixation effects on vertebral bone density and failure mechanics: an in-vitro study of human and sheep vertebrae. Clin Biomech 1994; 9:175-9.
    • (1994) Clin Biomech , vol.9 , pp. 175-179
    • Edmondston, S.J.1    Singer, K.P.2    Day, R.E.3
  • 5
    • 0028034777 scopus 로고
    • Effect of bone mineral density on pedicle screw fixation
    • Halvorson TL, Kelley LA, Thomas KA, et al. Effect of bone mineral density on pedicle screw fixation. Spine 1994;19:2415-20.
    • (1994) Spine , vol.19 , pp. 2415-2420
    • Halvorson, T.L.1    Kelley, L.A.2    Thomas, K.A.3
  • 6
    • 0025993922 scopus 로고
    • Cotrel-Dubousset pedicle screw systems for various spinal disorders: Merits and problems
    • Hirabayashi S, Kumano K, Kuroki T. Cotrel-Dubousset pedicle screw systems for various spinal disorders: merits and problems. Spine 1991;16:1298-304.
    • (1991) Spine , vol.16 , pp. 1298-1304
    • Hirabayashi, S.1    Kumano, K.2    Kuroki, T.3
  • 7
    • 0031419970 scopus 로고    scopus 로고
    • Structural characteristics of the pedicle and its role in screw stability
    • Hirano T, Hasegawa K, Takahashi HE, et al. Structural characteristics of the pedicle and its role in screw stability. Spine 1997; 22:2504-10.
    • (1997) Spine , vol.22 , pp. 2504-2510
    • Hirano, T.1    Hasegawa, K.2    Takahashi, H.E.3
  • 8
    • 0022653406 scopus 로고
    • Techniques of internal fixation for degenerative conditions of the lumbar spine
    • Kostuik JP, Errico TJ, Gleason TF. Techniques of internal fixation for degenerative conditions of the lumbar spine. Clin Orthop 1986;203:219-31.
    • (1986) Clin Orthop , vol.203 , pp. 219-231
    • Kostuik, J.P.1    Errico, T.J.2    Gleason, T.F.3
  • 9
    • 0031416028 scopus 로고    scopus 로고
    • Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine
    • Lotz JC, Hu SS, Chiu DFM, et al. Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine 1997;22:2716-23.
    • (1997) Spine , vol.22 , pp. 2716-2723
    • Lotz, J.C.1    Hu, S.S.2    Chiu, D.F.M.3
  • 10
    • 0031415073 scopus 로고    scopus 로고
    • The effect of bone quality on pedicle screw loading in axial instability: A synthetic model
    • McLain RF, McKinley TO, Yerby SA, et al. The effect of bone quality on pedicle screw loading in axial instability: a synthetic model. Spine 1997;22:1454-60.
    • (1997) Spine , vol.22 , pp. 1454-1460
    • McLain, R.F.1    McKinley, T.O.2    Yerby, S.A.3
  • 11
    • 0031424553 scopus 로고    scopus 로고
    • Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement
    • Moore DC, Maitra RS, Farjo LA, et al. Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement. Spine 1997;22:1696-705.
    • (1997) Spine , vol.22 , pp. 1696-1705
    • Moore, D.C.1    Maitra, R.S.2    Farjo, L.A.3
  • 12
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine
    • Okuyama K, Sato K, Abe E, et al. Stability of transpedicle screwing for the osteoporotic spine. Spine 1993;18:2240-5.
    • (1993) Spine , vol.18 , pp. 2240-2245
    • Okuyama, K.1    Sato, K.2    Abe, E.3
  • 13
    • 0028314201 scopus 로고
    • Repair of failed transpedicle screw fixation: A biomechanical study comparing polymethy-methacrylate, milled bone, and matchstick bone reconstruction
    • Pfeifer BA, Krag MH, Johnson C. Repair of failed transpedicle screw fixation: a biomechanical study comparing polymethy-methacrylate, milled bone, and matchstick bone reconstruction. Spine 1994;19:350-3.
    • (1994) Spine , vol.19 , pp. 350-353
    • Pfeifer, B.A.1    Krag, M.H.2    Johnson, C.3
  • 14
    • 0022625438 scopus 로고
    • Internal fixation of the lumbar spine with pedicle screw plating
    • Roy-Camille R, Saillant G, Mazel C. Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 1986;203:7-17.
    • (1986) Clin Orthop , vol.203 , pp. 7-17
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 15
    • 0023709062 scopus 로고
    • Pedicle screws: Axial pull-out strength in the lumbar spine
    • Sell P, Collins M, Dove J. Pedicle screws: axial pull-out strength in the lumbar spine. Spine 1988;13:1075-6.
    • (1988) Spine , vol.13 , pp. 1075-1076
    • Sell, P.1    Collins, M.2    Dove, J.3
  • 16
    • 0002458757 scopus 로고
    • A biomechanical strength of the vertebra with osteoporosis using hydroxyapatite cement injection
    • in Japanese
    • Shibata T, Yamamoto H, Iai H, et al. A biomechanical strength of the vertebra with osteoporosis using hydroxyapatite cement injection. J Jpn Spine Res Soc 1995;6:61-9 (in Japanese).
    • (1995) J Jpn Spine Res Soc , vol.6 , pp. 61-69
    • Shibata, T.1    Yamamoto, H.2    Iai, H.3
  • 17
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991;16:1335-41.
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3
  • 18
    • 0022642420 scopus 로고
    • Segmental spine plates with pedicle screw fixation: A new internal fixation device for disorders of the lumbar and thoracolumbar spine
    • Steffee AD, Biscup RS, Sitkowski DJ. Segmental spine plates with pedicle screw fixation: a new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop 1986;203:45-53.
    • (1986) Clin Orthop , vol.203 , pp. 45-53
    • Steffee, A.D.1    Biscup, R.S.2    Sitkowski, D.J.3
  • 19
    • 0028012866 scopus 로고
    • Neurological deterioration after cement injection into a vertebral body
    • Wilkes RA, Mackinnon JG, Thomas WG. Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 1994;76:155.
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 155
    • Wilkes, R.A.1    Mackinnon, J.G.2    Thomas, W.G.3
  • 20
    • 0025903474 scopus 로고
    • Importance of bone mineral density in instrumented spine fusions
    • Wittenberg RH, Shea M, Swartz DE, et al. Importance of bone mineral density in instrumented spine fusions. Spine 1991;16:647-52.
    • (1991) Spine , vol.16 , pp. 647-652
    • Wittenberg, R.H.1    Shea, M.2    Swartz, D.E.3
  • 21
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • Wittenberg RH, Lee K-S, Shea M, et al. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop 1993;296:278-87.
    • (1993) Clin Orthop , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.-S.2    Shea, M.3
  • 22
    • 0034528813 scopus 로고    scopus 로고
    • Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: An innovative technique
    • Wuisman PIJM, Van Dijk M, Staal H, et al. Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique. Eur Spine J 2000;9:528-33.
    • (2000) Eur Spine J , vol.9 , pp. 528-533
    • Wuisman, P.1    Van Dijk, M.2    Staal, H.3
  • 23
    • 0001098733 scopus 로고
    • Mechanical properties of locomotor organs and tissues
    • Evans FG, editor. Baltimore: Williams & Wilkins
    • Yamada H. Mechanical properties of locomotor organs and tissues. In: Evans FG, editor. Strength of biological materials. Baltimore: Williams & Wilkins; 1970. p. 19-80.
    • (1970) Strength of Biological Materials , pp. 19-80
    • Yamada, H.1
  • 24
    • 0026505213 scopus 로고
    • Mechanical stability of the pedicle screw fixation systems for the lumbar spine
    • Yamagata M, Kitahara H, Minami S, et al. Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine 1992;17:S51-4.
    • (1992) Spine , vol.17
    • Yamagata, M.1    Kitahara, H.2    Minami, S.3
  • 25
    • 0032143033 scopus 로고    scopus 로고
    • Revision of failed pedicle screws using hydroxyapatite cement: A biomechanical analysis
    • Yerby SA, Toh E, McLain RF. Revision of failed pedicle screws using hydroxyapatite cement: a biomechanical analysis. Spine 1998;23:1657-61.
    • (1998) Spine , vol.23 , pp. 1657-1661
    • Yerby, S.A.1    Toh, E.2    McLain, R.F.3
  • 26
    • 0022628372 scopus 로고
    • A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 1986;203:99-112.
    • (1986) Clin Orthop , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.