메뉴 건너뛰기




Volumn 55, Issue 6, 2009, Pages 368-373

Comparison of the use of liquid crystal thermometers with glass mercury thermometers in febrile children in a children's ward at Port Moresby General Hospital, Papua New Guinea

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ARTICLE; BODY TEMPERATURE MEASUREMENT; CHILD; CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; FEVER; GENERAL HOSPITAL; HUMAN; INTERMETHOD COMPARISON; LIQUID CRYSTAL THERMOMETER; MAJOR CLINICAL STUDY; MALE; MERCURY THERMOMETER; PAPUA NEW GUINEA; PRESCHOOL CHILD; THERMOMETER;

EID: 73049103627     PISSN: 01426338     EISSN: 14653664     Source Type: Journal    
DOI: 10.1093/tropej/fmp027     Document Type: Article
Times cited : (5)

References (22)
  • 1
    • 0034917506 scopus 로고    scopus 로고
    • Evaluation of clinical thermometers for accuracy and reliability
    • Latman NS, Hans P, Nicholson L, et al. Evaluation of clinical thermometers for accuracy and reliability. Biomed Instrum Technol 2001;35:259-65.
    • (2001) Biomed Instrum Technol , vol.35 , pp. 259-265
    • Latman, N.S.1    Hans, P.2    Nicholson, L.3
  • 3
    • 0031819868 scopus 로고    scopus 로고
    • Unreliability of the infrared tympanic thermometer in clinical practice: a comparative study with oral mercury and oral electronic thermometers
    • Modell JG, Katholi CR, Kumaramangalam SM, et al. Unreliability of the infrared tympanic thermometer in clinical practice: a comparative study with oral mercury and oral electronic thermometers. South Med J 1998;91:649-54.
    • (1998) South Med J , vol.91 , pp. 649-654
    • Modell, J.G.1    Katholi, C.R.2    Kumaramangalam, S.M.3
  • 4
    • 0031855749 scopus 로고    scopus 로고
    • Lack of agreement between tympanic and oral temperature measurement in adult hospitalized patients
    • Manian FA, Griesenauer S. Lack of agreement between tympanic and oral temperature measurement in adult hospitalized patients. Am J Infect Control 1998;26:428-30.
    • (1998) Am J Infect Control , vol.26 , pp. 428-430
    • Manian, F.A.1    Griesenauer, S.2
  • 5
    • 0031178743 scopus 로고    scopus 로고
    • A difference of 5 degrees Celcius between ear and rectal temperatures in a febrile patient
    • Romanovsky AA, Quint PA, Benikova Y, et al. A difference of 5 degrees Celcius between ear and rectal temperatures in a febrile patient. Am J Emerg Med 1997;15:383-5.
    • (1997) Am J Emerg Med , vol.15 , pp. 383-385
    • Romanovsky, A.A.1    Quint, P.A.2    Benikova, Y.3
  • 6
    • 0030065795 scopus 로고    scopus 로고
    • Screening for fever in an adult emergency department: oral vs tympanic thermometry
    • Hooker EA, Houston H. Screening for fever in an adult emergency department: oral vs tympanic thermometry. South Med J 1996;89:230-4.
    • (1996) South Med J , vol.89 , pp. 230-234
    • Hooker, E.A.1    Houston, H.2
  • 7
    • 0027236627 scopus 로고
    • Use of tympanic thermometers to screen for fever in patients in a paediatric emergency department
    • Hooker EA. Use of tympanic thermometers to screen for fever in patients in a paediatric emergency department. South Med J 1993;86:855-8.
    • (1993) South Med J , vol.86 , pp. 855-858
    • Hooker, E.A.1
  • 8
    • 0028887640 scopus 로고
    • Reliability of infrared tympanic thermometry in the detection of rectal fever in children
    • Brennan DF, Falk JL, Rothrock SG, et al. Reliability of infrared tympanic thermometry in the detection of rectal fever in children. Ann Emerg Med 1995;25:21-30
    • (1995) Ann Emerg Med , vol.25 , pp. 21-23
    • Brennan, D.F.1    Falk, J.L.2    Rothrock, S.G.3
  • 9
    • 0018149590 scopus 로고
    • Continuous monitoring of skin temperature using a liquid crystal thermometer during anaesthesia
    • Burgess GE, Cooper JR III, Marino RJ, et al. Continuous monitoring of skin temperature using a liquid crystal thermometer during anaesthesia. South Med J 1978;71:516-8.
    • (1978) South Med J , vol.71 , pp. 516-518
    • Burgess, G.E.1    Cooper Jr. III2    Marino, R.J.3
  • 10
    • 0018214642 scopus 로고
    • An evaluation of liquid-crystal thermometry as a screening device for interoperative hyperthermia
    • Lees DE, Schuette W, Bukll JM, et al. An evaluation of liquid-crystal thermometry as a screening device for interoperative hyperthermia. Anesth Analg 1978;57: 669-74.
    • (1978) Anesth Analg , vol.57 , pp. 669-674
    • Lees, D.E.1    Schuette, W.2    Bukll, J.M.3
  • 11
    • 0029646368 scopus 로고
    • Comparison of disposable and glass mercury thermometers
    • Board M. Comparison of disposable and glass mercury thermometers. Nurs Times 1995;91:36-7.
    • (1995) Nurs Times , vol.91 , pp. 36-37
    • Board, M.1
  • 12
    • 0028395688 scopus 로고
    • Comparison of standard mercury thermometer and the liquid crystal device skin contact thermometer in febrile children at Eldoret District Hospital
    • Esamai F. Comparison of standard mercury thermometer and the liquid crystal device skin contact thermometer in febrile children at Eldoret District Hospital. East Afr Med J 1994;71:193-4.
    • (1994) East Afr Med J , vol.71 , pp. 193-194
    • Esamai, F.1
  • 15
    • 0020042956 scopus 로고
    • Liquid crystal forehead temperature strips. A clinical appraisal
    • Scholefield JM, Gerber MA, Dwyer P. Liquid crystal forehead temperature strips. A clinical appraisal. Am J Dis Child 1982;136:198-201.
    • (1982) Am J Dis Child , vol.136 , pp. 198-201
    • Scholefield, J.M.1    Gerber, M.A.2    Dwyer, P.3
  • 16
    • 0029037533 scopus 로고
    • Comparing liquid crystal thermometer readings and mercury thermometer readings of infants and small children in a traditional African setting. Implications for community-based health
    • Valadez JJ, Elmore-Meegan M, Morely D. Comparing liquid crystal thermometer readings and mercury thermometer readings of infants and small children in a traditional African setting. Implications for community-based health. Trop Geogr Med 1995;47:130-3.
    • (1995) Trop Geogr Med , vol.47 , pp. 130-133
    • Valadez, J.J.1    Elmore-Meegan, M.2    Morely, D.3
  • 17
    • 0031908873 scopus 로고    scopus 로고
    • Liquid Crystal Thermometry for the detection of neonatal hypothermia in Nepal
    • Manandhar N, Ellis M, Manandhar DS, et al. Liquid Crystal Thermometry for the detection of neonatal hypothermia in Nepal. J Trop Pediatr 1998;44:15-7.
    • (1998) J Trop Pediatr , vol.44 , pp. 15-17
    • Manandhar, N.1    Ellis, M.2    Manandhar, D.S.3
  • 19
    • 73049095133 scopus 로고    scopus 로고
    • Note
    • R Disposable and reusable thermometer. Medical Indicators USA. Advertisement and Product Information.
  • 20
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical assessment
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical assessment. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 33646558264 scopus 로고    scopus 로고
    • Nextemp thermometer can be used interchangeably with tympanic or mercury thermometer for emergency department use
    • Rajee M, Sultana RV. Nextemp thermometer can be used interchangeably with tympanic or mercury thermometer for emergency department use. Emerg Med Austr 2006;18:245-51.
    • (2006) Emerg Med Austr , vol.18 , pp. 245-251
    • Rajee, M.1    Sultana, R.V.2
  • 22
    • 0038728759 scopus 로고    scopus 로고
    • Evaluation of a new, wearable, precision phase-change thermometer in neonates
    • McKenzie NE. Evaluation of a new, wearable, precision phase-change thermometer in neonates. Paediatr Nurs 2003;29:117 25.
    • (2003) Paediatr Nurs , vol.29 , pp. 117-125
    • McKenzie, N.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.