메뉴 건너뛰기




Volumn 18, Issue 3, 2006, Pages 245-251

NexTemp thermometer can be used interchangeably with tympanic or mercury thermometers for emergency department use

Author keywords

Adult; Body temperature; Fever; Thermography; Thermometer

Indexed keywords

ADULT; ARTICLE; AUSTRALIA; BODY TEMPERATURE MEASUREMENT; CHEMICAL THERMOMETER; EMERGENCY WARD; HUMAN; MAJOR CLINICAL STUDY; MERCURY THERMOMETER; PRIORITY JOURNAL; PRIVATE HOSPITAL; PROSPECTIVE STUDY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; THERMOGRAPHY; TYMPANIC THERMOMETER;

EID: 33646558264     PISSN: 17426731     EISSN: 17426723     Source Type: Journal    
DOI: 10.1111/j.1742-6723.2006.00847.x     Document Type: Article
Times cited : (11)

References (13)
  • 2
    • 0031819868 scopus 로고    scopus 로고
    • Unreliability of the infrared tympanic thermometer in clinical practice: A comparative study with oral mercury and oral electronic thermometers
    • Modell JG Katholi CR Kumaramangalam SM Hudson EC Graham D Unreliability of the infrared tympanic thermometer in clinical practice: a comparative study with oral mercury and oral electronic thermometers South MedJ 1998 91 649 54
    • (1998) South MedJ , vol.91 , pp. 649-54
    • Modell G, J.1    Katholi, C.R.2    Kumaramangalam, S.M.3    Hudson, E.C.4    Graham, D.5
  • 3
    • 17844409554 scopus 로고    scopus 로고
    • Temperature measurement: Comparison of non-invasive methods used in adult critical care
    • Farnell S Maxwell L Tan S Rhodes A Philips B Temperature measurement: comparison of non-invasive methods used in adult critical care JClinNurs 2005 14 632 9
    • (2005) JClinNurs , vol.14 , pp. 632-9
    • Farnell S1    Maxwell, L.2    Tan, S.3    Rhodes, A.4    Philips, B.5
  • 4
    • 0034223069 scopus 로고    scopus 로고
    • Temperature measurement in critically ill adult: A comparison of tympanic and oral methods
    • Giuliano KK Giuliano AJ Scott SS et al. Temperature measurement in critically ill adult: a comparison of tympanic and oral methods AmJCrit Care 2000 9 334 43
    • (2000) AmJCrit Care , vol.9 , pp. 334-43
    • Giuliano K, K.1    Giuliano, A.J.2    Scott, S.S.3
  • 5
    • 0033816314 scopus 로고    scopus 로고
    • The accuracy of oral predictive and infrared emission detection tympanic thermometers in an emergency department setting
    • O'Brien DL Rogers IR Holden W et al. The accuracy of oral predictive and infrared emission detection tympanic thermometers in an emergency department setting AcadEmergMed 2000 7 1061 4
    • (2000) AcadEmergMed , vol.7 , pp. 1061-4
    • O'Brien L, D.1    Rogers, I.R.2    Holden, W.3
  • 6
    • 0032196675 scopus 로고    scopus 로고
    • A comparison of temperature measurements using three ear thermometers
    • Weiss ME Sitzer V Clarke M et al. A comparison of temperature measurements using three ear thermometers ApplNurs Res 1998 11 158 66
    • (1998) ApplNurs Res , vol.11 , pp. 158-66
    • Weiss E, M.1    Sitzer, V.2    Clarke, M.3
  • 7
    • 0033763404 scopus 로고    scopus 로고
    • Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
    • Jensen BN Jensen FS Madsen SN Lossl K Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers EurJSurg 2000 166 848 51
    • (2000) EurJSurg , vol.166 , pp. 848-51
    • Jensen N, B.1    Jensen, F.S.2    Madsen, S.N.3    Lossl, K.4
  • 8
    • 0025977593 scopus 로고
    • Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children
    • Muma BK Treloar DJ Wurmlinger K Peterson E Vitae A Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children AnnEmerg Med 1991 20 41 4
    • (1991) AnnEmerg Med , vol.20 , pp. 41-4
    • Muma K, B.1    Treloar, D.J.2    Wurmlinger, K.3    Peterson, E.4    Vitae, A.5
  • 9
    • 1542754889 scopus 로고    scopus 로고
    • Evaluation of chemical dot thermometers for measuring body temperature of orally intubated patients
    • Potter P Schallom M Davis S Sona C McSweeney M Evaluation of chemical dot thermometers for measuring body temperature of orally intubated patients AmJCritCare 2003 12 403 7
    • (2003) AmJCritCare , vol.12 , pp. 403-7
    • Potter P1    Schallom, M.2    Davis, S.3    Sona, C.4    McSweeney, M.5
  • 10
    • 0141992720 scopus 로고    scopus 로고
    • Pediatric temperature measurement and child/parent/nurse preference using three temperature measurement instruments
    • Barton SJ Gaffney R Chase T Rayens MK Piyabanditkul L Pediatric temperature measurement and child/parent/nurse preference using three temperature measurement instruments JPediatrNurs 2003 18 314 20
    • (2003) JPediatrNurs , vol.18 , pp. 314-20
    • Barton J, S.1    Gaffney, R.2    Chase, T.3    Rayens, M.K.4    Piyabanditkul, L.5
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM Altman DG Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1986 1 307 10
    • (1986) Lancet , vol.1 , pp. 307-10
    • Bland M, J.1    Altman, D.G.2
  • 12
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM Altman DG Comparing methods of measurement: why plotting difference against standard method is misleading Lancet 1995 346 1085 7
    • (1995) Lancet , vol.346 , pp. 1085-7
    • Bland M, J.1    Altman, D.G.2
  • 13
    • 0038728759 scopus 로고    scopus 로고
    • Evaluation of a new, wearable, precision phase-change thermometer in neonates
    • McKenzie NE Evaluation of a new, wearable, precision phase-change thermometer in neonates PediatrNurs 2003 29 117 25
    • (2003) PediatrNurs , vol.29 , pp. 117-25
    • McKenzie E, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.