메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Finite element analysis of LTI carbon hip joint head

Author keywords

Artificial hip joints; Biomaterials; Finite element analysis; Semi hip replacement component

Indexed keywords

3D FINITE ELEMENT MODEL; ARTIFICIAL HIP JOINT; ARTIFICIAL HIP JOINTS; CARBON MATERIAL; CONTACT AREAS; FEMORAL HEADS; FINITE ELEMENT ANALYSIS; HIP JOINTS; HIP REPLACEMENTS; LOW ELASTIC MODULUS; STRESS DISTRIBUTION;

EID: 72749099611     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBBE.2009.5162859     Document Type: Conference Paper
Times cited : (1)

References (17)
  • 1
    • 0024327237 scopus 로고
    • Thompson hemiathtroplasty and acet abular erosion
    • Philips TW. Thompson hemiathtroplasty and acet abular erosion. J Bone Joint Surg(Am), 1989, 71:913.
    • (1989) J Bone Joint Surg(Am) , vol.71 , pp. 913
    • Philips, T.W.1
  • 2
    • 3543001649 scopus 로고    scopus 로고
    • Gutmanas E Y, Gotman I Pirac. Ti nitride coated Ti-6Al-4V head against UHMWPE acetabular cup- hip wear simulator study. J Mater Sci:Mater Med, 2004, 15(4): 327
    • Gutmanas E Y, Gotman I Pirac. Ti nitride coated Ti-6Al-4V head against UHMWPE acetabular cup- hip wear simulator study. J Mater Sci:Mater Med, 2004, 15(4): 327
  • 3
    • 1942434585 scopus 로고    scopus 로고
    • Buford A, Goswami T. Review of wear mechanisms in hip implants: Paper I- General. Mater Desi, 2004, 25: 385
    • Buford A, Goswami T. Review of wear mechanisms in hip implants: Paper I- General. Mater Desi, 2004, 25: 385
  • 4
    • 72749087367 scopus 로고    scopus 로고
    • Cheng Lantian,Jiang Kunyuan,Liu Peitong. Carbon bio-material's application study should be paid attention. Chinese Journal of Orthopaedics, 1995, 4.4 (15) 246.
    • Cheng Lantian,Jiang Kunyuan,Liu Peitong. Carbon bio-material's application study should be paid attention. Chinese Journal of Orthopaedics, 1995, 4.4 (15) 246.
  • 5
    • 72749099130 scopus 로고    scopus 로고
    • the journal of bone and joint inury 1997,6(12):332.
    • the journal of bone and joint inury 1997,6(12):332.
  • 6
    • 72749124533 scopus 로고    scopus 로고
    • A follow-up visit made after carbon-titanium composite artificial femoral head has been used in clinical application for 15 years
    • A follow-up visit made after carbon-titanium composite artificial femoral head has been used in clinical application for 15 years.
  • 7
    • 72749106416 scopus 로고    scopus 로고
    • Hu Ming, Cheng Lantian,Luan Shangwen, Results of a long run follow-up visit about carbon-titanium composite artificial femoral head's clinical application
    • Hu Ming, Cheng Lantian,Luan Shangwen, Results of a long run follow-up visit about carbon-titanium composite artificial femoral head's clinical application
  • 9
    • 72749083973 scopus 로고    scopus 로고
    • Determination of suitable sample sizes for multi-patient based finite element studies
    • I.A.J. Radcliffe, P. Prescott, H.S. Man.Determination of suitable sample sizes for multi-patient based finite element studies. Medical Engineering & Physics,2007; JJBE-1233:8
    • (2007) Medical Engineering & Physics , vol.JJBE-1233 , pp. 8
    • Radcliffe, I.A.J.1    Prescott, P.2    Man, H.S.3
  • 10
    • 33846267717 scopus 로고    scopus 로고
    • F Cosmi1, M Hoglievina, G Fancellu. A finite element method comparison of wear in two metal-on-metal total hip prostheses. J. Engineering in Medicine.2006;220:871
    • F Cosmi1, M Hoglievina, G Fancellu. A finite element method comparison of wear in two metal-on-metal total hip prostheses. J. Engineering in Medicine.2006;220:871
  • 12
    • 15044342783 scopus 로고    scopus 로고
    • Oki H, Ando M, Omori H, et al. Relation between vertical oriatation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method . Arif organs ,2004;28:1050
    • Oki H, Ando M, Omori H, et al. Relation between vertical oriatation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method . Arif organs ,2004;28:1050
  • 14
    • 72749123629 scopus 로고    scopus 로고
    • Pelvic muscle and acetabulat contact forces during gait [J]
    • Pedersen DR,Brand RA, Davy DT. Pelvic muscle and acetabulat contact forces during gait [J]. Proc Inst Mech Eng, 2000,214(6):685.
    • (2000) Proc Inst Mech Eng , vol.214 , Issue.6 , pp. 685
    • Pedersen, D.R.1    Brand, R.A.2    Davy, D.T.3
  • 15
    • 72749107754 scopus 로고    scopus 로고
    • Zou yuanyuan,Wang Yulin,ZhangTieliang, A research to jiggle and biomechanics on joint surface of combined type artificial hip Chinese Journal of Clinical Anatomy
    • Zou yuanyuan,Wang Yulin,ZhangTieliang, A research to jiggle and biomechanics on joint surface of combined type artificial hip Chinese Journal of Clinical Anatomy
  • 16
    • 72749092099 scopus 로고    scopus 로고
    • Wang Guanghua, a finite element analysis to biomechanics in pelvic and acetabular during walking and Fixation system for curing acetabular friction
    • Wang Guanghua, a finite element analysis to biomechanics in pelvic and acetabular during walking and Fixation system for curing acetabular friction
  • 17
    • 0842329793 scopus 로고    scopus 로고
    • Carbon-carbon composite bearing materials in hip arthroplasty: Analysis of wear and biological response to wear debris
    • Howing G I, Ingham E. Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris. J Mater Sci Mater Med 2004, 15: 91
    • (2004) J Mater Sci Mater Med , vol.15 , pp. 91
    • Howing, G.I.1    Ingham, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.