Relation between vertical orientation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method

Author keywords

Acetabular component; Contact stress; Cup abduction angle; Relative motion; Shear stress

Indexed keywords

ARTHROPLASTY; BONE; FINITE ELEMENT METHOD; HIP PROSTHESES; METALS; POLYETHYLENES;

EID: 15044342783     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2004.00017.x     Document Type: Article
Times cited : (29)

References (35)
  • 1
    • 0031017797 scopus 로고    scopus 로고
    • Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up
    • Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am 1997;79-A:159-68.
    • (1997) J Bone Joint Surg Am , vol.79 A , pp. 159-168
    • Shinar, A.A.1    Harris, W.H.2
  • 2
    • 0025679359 scopus 로고
    • Failure of acetabular autogenous grafts in total hip arthroplasty. Increasing incidence: A follow-up note
    • Mulroy RD Jr, Harris WH. Failure of acetabular autogenous grafts in total hip arthroplasty. Increasing incidence: a follow-up note. J Bone Joint Surg Am 1990;72-A:1536-40.
    • (1990) J Bone Joint Surg Am , vol.72 A , pp. 1536-1540
    • Mulroy Jr., R.D.1    Harris, W.H.2
  • 3
    • 0025338887 scopus 로고
    • Femoral head autografting with total hip arthroplasty for lateral acetabular dysplasia. A 12-year experience
    • Wolfgang GL. Femoral head autografting with total hip arthroplasty for lateral acetabular dysplasia. A 12-year experience. Clin Orthop 1990;255:173-85.
    • (1990) Clin Orthop , vol.255 , pp. 173-185
    • Wolfgang, G.L.1
  • 4
    • 0031851235 scopus 로고    scopus 로고
    • An oblong revision cup for large acetabular defects: Design rationale and two- to seven-year follow-up
    • Köster G, Willert HG, Köhler HP, Döpkens K. An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplasty 1998;13:559-69.
    • (1998) J Arthroplasty , vol.13 , pp. 559-569
    • Köster, G.1    Willert, H.G.2    Köhler, H.P.3    Döpkens, K.4
  • 5
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 1998;13:530-4.
    • (1998) J Arthroplasty , vol.13 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3    Sullivan, R.J.4    Griffen, D.G.5    Sheehan, L.J.6
  • 6
    • 0017078724 scopus 로고
    • Total hip reconstruction in chronically dislocated hips
    • Dunn HK, Hess WE. Total hip reconstruction in chronically dislocated hips. J Bone Joint Surg Am 1976;58-A:838-45.
    • (1976) J Bone Joint Surg Am , vol.58 A , pp. 838-845
    • Dunn, H.K.1    Hess, W.E.2
  • 7
    • 0028042344 scopus 로고
    • High hip center in revision arthroplasty
    • Kelley SS. High hip center in revision arthroplasty. J Arthroplasty 1994;9:503-10.
    • (1994) J Arthroplasty , vol.9 , pp. 503-510
    • Kelley, S.S.1
  • 8
    • 0030055617 scopus 로고    scopus 로고
    • The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty
    • Pagnano W, Hanssen AD, Lewallen DG, Shaughnessy WJ. The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty. J Bone Joint Surg Am 1996;78-A:1004-14.
    • (1996) J Bone Joint Surg Am , vol.78 A , pp. 1004-1014
    • Pagnano, W.1    Hanssen, A.D.2    Lewallen, D.G.3    Shaughnessy, W.J.4
  • 9
    • 0025758756 scopus 로고
    • Proximal placement of the acetabular component in total hip arthroplasty. A long-term follow-up study
    • Russotti GM, Harris WH. Proximal placement of the acetabular component in total hip arthroplasty. A long-term follow-up study. J Bone Joint Surg Am 1991;73-A:587-92.
    • (1991) J Bone Joint Surg Am , vol.73 A , pp. 587-592
    • Russotti, G.M.1    Harris, W.H.2
  • 10
    • 0027236336 scopus 로고
    • Bone grafting for acetabular deficiency during primary and revision total hip arthroplasty. A radiographic and clinical analysis
    • Knight JL, Fujii K, Atwater R, Grothaus L. Bone grafting for acetabular deficiency during primary and revision total hip arthroplasty. A radiographic and clinical analysis. J Arthroplasty 1993;8:371-82.
    • (1993) J Arthroplasty , vol.8 , pp. 371-382
    • Knight, J.L.1    Fujii, K.2    Atwater, R.3    Grothaus, L.4
  • 11
    • 0028197478 scopus 로고
    • Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner
    • Bono JV, Sanford L, Toussaint JT. Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner [see comments]. J Arthroplasty 1994;9:119-25.
    • (1994) J Arthroplasty , vol.9 , pp. 119-125
    • Bono, J.V.1    Sanford, L.2    Toussaint, J.T.3
  • 12
    • 0031544132 scopus 로고    scopus 로고
    • Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris
    • Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 1997;12:256-66.
    • (1997) J Arthroplasty , vol.12 , pp. 256-266
    • Devane, P.A.1    Horne, J.G.2    Martin, K.3    Coldham, G.4    Krause, B.5
  • 13
    • 0031172144 scopus 로고    scopus 로고
    • The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components
    • Kurtz SM, Edidin AA, Bartel DL. The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components. J Biomech 1997;30:639-42.
    • (1997) J Biomech , vol.30 , pp. 639-642
    • Kurtz, S.M.1    Edidin, A.A.2    Bartel, D.L.3
  • 15
    • 0029125716 scopus 로고
    • Wear of the polyethylene of Harris-Galante acetabular components inserted without cement
    • Woolson ST, Murphy MG. Wear of the polyethylene of Harris-Galante acetabular components inserted without cement. J Bone Joint Surg Am 1995;77-A:1311-4.
    • (1995) J Bone Joint Surg Am , vol.77 A , pp. 1311-1314
    • Woolson, S.T.1    Murphy, M.G.2
  • 16
    • 0141451988 scopus 로고    scopus 로고
    • Intermediate-term results after hybrid total hip arthroplasty for the treatment of dysplastic hips
    • Ito H, Matsuno T, Minami A, Aoki Y. Intermediate-term results after hybrid total hip arthroplasty for the treatment of dysplastic hips. J Bone Joint Surg Am 2003;85-A:1725-32.
    • (2003) J Bone Joint Surg Am , vol.85 A , pp. 1725-1732
    • Ito, H.1    Matsuno, T.2    Minami, A.3    Aoki, Y.4
  • 17
    • 0030627862 scopus 로고    scopus 로고
    • Frictional heating of bearing materials tested in a hip joint wear simulator
    • Lu Z, McKellop H. Frictional heating of bearing materials tested in a hip joint wear simulator. Proc Inst Mech Eng [H] 1997;211:101-8.
    • (1997) Proc Inst Mech Eng [H] , vol.211 , pp. 101-108
    • Lu, Z.1    McKellop, H.2
  • 18
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
    • Shirazi-Adl A, Dammak M, Paiement G. Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. J Biomed Mater Res 1993;27:167-75.
    • (1993) J Biomed Mater Res , vol.27 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 19
    • 0027229915 scopus 로고
    • Total hip reconstruction in acetabular dysplasia. A finite element study
    • Schüller HM, Dalstra M, Huiskes R, Marti RK. Total hip reconstruction in acetabular dysplasia. A finite element study. J Bone Joint Surg Br 1993;75-B:468-74.
    • (1993) J Bone Joint Surg Br , vol.75 B , pp. 468-474
    • Schüller, H.M.1    Dalstra, M.2    Huiskes, R.3    Marti, R.K.4
  • 20
    • 0029310682 scopus 로고
    • Load transfer across the pelvic bone
    • Dalstra M, Huiskes R. Load transfer across the pelvic bone. J Biomech 1995;28:715-24.
    • (1995) J Biomech , vol.28 , pp. 715-724
    • Dalstra, M.1    Huiskes, R.2
  • 21
    • 0027897656 scopus 로고
    • Effects of porous coating, with and without collar support, on early relative motion for a cementless hip prosthesis
    • Keaveny TM, Bartel DL. Effects of porous coating, with and without collar support, on early relative motion for a cementless hip prosthesis. J Biomech 1993;26:1355-68.
    • (1993) J Biomech , vol.26 , pp. 1355-1368
    • Keaveny, T.M.1    Bartel, D.L.2
  • 22
    • 0025974270 scopus 로고
    • A finite element study of the effect of diametral interface gaps on the contact areas and pressures in uncemented cylindrical femoral total hip components
    • Harrigan TP, Harris WH. A finite element study of the effect of diametral interface gaps on the contact areas and pressures in uncemented cylindrical femoral total hip components. J Biomech 1991;24:87-91.
    • (1991) J Biomech , vol.24 , pp. 87-91
    • Harrigan, T.P.1    Harris, W.H.2
  • 23
    • 0015648310 scopus 로고
    • The effect of movement on the bonding of porous metal to bone
    • Cameron HU, Pilliar RM, MacNab I. The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 1973;7:301-11.
    • (1973) J Biomed Mater Res , vol.7 , pp. 301-311
    • Cameron, H.U.1    Pilliar, R.M.2    MacNab, I.3
  • 24
    • 0023687068 scopus 로고
    • Histologic analysis of retrieved human porous-coated total joint components
    • Cook SD, Thomas KA, Haddad RJ Jr. Histologic analysis of retrieved human porous-coated total joint components. Clin Orthop 1988;234:90-101.
    • (1988) Clin Orthop , vol.234 , pp. 90-101
    • Cook, S.D.1    Thomas, K.A.2    Haddad Jr., R.J.3
  • 25
    • 0022630597 scopus 로고
    • The effect of load alteration on the biological and biomechanical performance of a titanium fiber-metal segmental prosthesis
    • Heck DA, Nakajima I, Kelly PJ, Chao EY. The effect of load alteration on the biological and biomechanical performance of a titanium fiber-metal segmental prosthesis. J Bone Joint Surg Am 1986;68-A:118-26.
    • (1986) J Bone Joint Surg Am , vol.68 A , pp. 118-126
    • Heck, D.A.1    Nakajima, I.2    Kelly, P.J.3    Chao, E.Y.4
  • 26
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop 1986;208:108-13.
    • (1986) Clin Orthop , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 27
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992;10:285-99.
    • (1992) J Orthop Res , vol.10 , pp. 285-299
    • Soballe, K.1    Hansen, E.S.2    B-Rasmussen, H.3    Jorgensen, P.H.4    Bunger, C.5
  • 28
    • 0026457532 scopus 로고
    • Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses
    • Engh CA, O'Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop 1992;285:13-29.
    • (1992) Clin Orthop , vol.285 , pp. 13-29
    • Engh, C.A.1    O'Connor, D.2    Jasty, M.3    McGovern, T.F.4    Bobyn, J.D.5    Harris, W.H.6
  • 29
    • 0031052909 scopus 로고    scopus 로고
    • Cement debonding process of total hip arthroplasty stems
    • Verdonschot N, Huiskes R. Cement debonding process of total hip arthroplasty stems. Clin Orthop 1997;336:297-307.
    • (1997) Clin Orthop , vol.336 , pp. 297-307
    • Verdonschot, N.1    Huiskes, R.2
  • 30
    • 0028822681 scopus 로고
    • Preclinical testing of total hip stems. The effects of coating placement
    • Huiskes R, van Rietbergen B. Preclinical testing of total hip stems. The effects of coating placement. Clin Orthop 1995;319:64-76.
    • (1995) Clin Orthop , vol.319 , pp. 64-76
    • Huiskes, R.1    Van Rietbergen, B.2
  • 31
    • 0028325196 scopus 로고
    • Osteolysis and particle disease in hip replacement. A review
    • Harris WH. Osteolysis and particle disease in hip replacement. A review. Acta Orthop Scand 1994;65:113-23.
    • (1994) Acta Orthop Scand , vol.65 , pp. 113-123
    • Harris, W.H.1
  • 32
    • 0023860303 scopus 로고
    • A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles
    • Howie DW, Vernon RB, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am 1988;70-A:257-63.
    • (1988) J Bone Joint Surg Am , vol.70 A , pp. 257-263
    • Howie, D.W.1    Vernon, R.B.2    Oakeshott, R.3    Manthey, B.4
  • 33
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • Bartel DL, Burstein AH, Toda MD, Edwards DL. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 1985;107:193-9.
    • (1985) J Biomech Eng , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 34
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am 1986;68-A:1041-51.
    • (1986) J Bone Joint Surg Am , vol.68 A , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 35
    • 0028500036 scopus 로고
    • A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups
    • Jin ZM, Dowson D, Fisher J. A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups. Med Eng Phys 1994;16:398-405.
    • (1994) Med Eng Phys , vol.16 , pp. 398-405
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.