Volumn , Issue , 2009, Pages 631-638

Fault monitoring and control of PEM fuel cell as backup power for UPS applications

Author keywords

Expert monitoring system; Intelligent comprehensive control; Proton exchange membrane (PEM) fuel cell; Uninterruptible power supply (UPS)

Indexed keywords

BACK-UP POWER; BATTERY POWER; CONTROL PANELS; CONVERSION FUNCTION; EXPERT MONITORING SYSTEM; FAULT MONITORING; HIGH QUALITY POWER; INDUSTRY APPLICATIONS; MONITORING SYSTEM; PEM FUEL CELL; POWER MANAGEMENTS; UNINTERRUPTIBLE POWER SUPPLIES; UPS APPLICATIONS; UPS SYSTEMS;

EID: 72449189245     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ECCE.2009.5316548     Document Type: Conference Paper
Times cited : (6)

References (22)
  • 1
    • 30144442318 scopus 로고    scopus 로고
    • High efficiency fuel cell based uninterruptible power supply for digital equipment
    • J. Gonzales and G. Tamizhmani. "High efficiency fuel cell based uninterruptible power supply for digital equipment," Journal of Power Sources, vol. 153, pp. 151-156, 2006.
    • (2006) Journal of Power Sources , vol.153 , pp. 151-156
    • Gonzales, J.1    Tamizhmani, G.2
  • 3
    • 1542273215 scopus 로고    scopus 로고
    • Diagnosis of automotive fuel cell power generators
    • D. Hissel, M. C. Péra, and J. M. Kauffmann, "Diagnosis of automotive fuel cell power generators," Journal of Power Sources, vol. 128, pp. 239-246, 2004.
    • (2004) Journal of Power Sources , vol.128 , pp. 239-246
    • Hissel, D.1    Péra, M.C.2    Kauffmann, J.M.3
  • 6
    • 33749991059 scopus 로고    scopus 로고
    • Diagnostic tool to detect liquid water removal in the cathode channels of proton exchange membrane fuel cells
    • H. P. Ma, H. M. Zhang, J. Hua, Y. H. Cai, and B. L. Yi, "Diagnostic tool to detect liquid water removal in the cathode channels of proton exchange membrane fuel cells," Journal of Power Sources, vol. 162, pp. 469-473, 2006.
    • (2006) Journal of Power Sources , vol.162 , pp. 469-473
    • Ma, H.P.1    Zhang, H.M.2    Hua, J.3    Cai, Y.H.4    Yi, B.L.5
  • 7
    • 36348986170 scopus 로고    scopus 로고
    • On-line fault diagnostic system for proton exchange membrane fuel cells
    • L. Riascos, M. Simoes, and P. Miyagi, "On-line fault diagnostic system for proton exchange membrane fuel cells," Journal of Power Sources, vol. 175, pp. 419-429, 2008.
    • (2008) Journal of Power Sources , vol.175 , pp. 419-429
    • Riascos, L.1    Simoes, M.2    Miyagi, P.3
  • 8
    • 37549020091 scopus 로고    scopus 로고
    • Model-based control of cathode pressure and oxygen excess ratio of a PEM fuel cell system
    • M. A. Danzer, J. Wilhelm, H. Aschemann, and E. P. Hofer, "Model-based control of cathode pressure and oxygen excess ratio of a PEM fuel cell system," Journal of Power Sources, vol. 176, pp. 515-522, 2008.
    • (2008) Journal of Power Sources , vol.176 , pp. 515-522
    • Danzer, M.A.1    Wilhelm, J.2    Aschemann, H.3    Hofer, E.P.4
  • 9
    • 40849125459 scopus 로고    scopus 로고
    • An application of indirect model reference adaptive control to a low-power proton exchange membrane fuel cell
    • Y. P. Yang, Z. W. Liu, and F. C. Wang, "An application of indirect model reference adaptive control to a low-power proton exchange membrane fuel cell," Journal of Power Sources, vol. 179, pp. 618-630, 2008.
    • (2008) Journal of Power Sources , vol.179 , pp. 618-630
    • Yang, Y.P.1    Liu, Z.W.2    Wang, F.C.3
  • 10
    • 56049104880 scopus 로고    scopus 로고
    • Analysis and control of a hybrid fuel delivery system for a polymer electrolyte membrane fuel cell
    • J. L. He, S. Y. Choe, and C. Hong, "Analysis and control of a hybrid fuel delivery system for a polymer electrolyte membrane fuel cell," Journal of Power Sources, vol. 185, pp. 973-984, 2008.
    • (2008) Journal of Power Sources , vol.185 , pp. 973-984
    • He, J.L.1    Choe, S.Y.2    Hong, C.3
  • 11
    • 33846818850 scopus 로고    scopus 로고
    • Dynamic analysis and linear control strategies for proton exchange membrane fuel cell using a distributed parameter model
    • R. N. Methekar, V. Prasad, and R. D. Gudi, "Dynamic analysis and linear control strategies for proton exchange membrane fuel cell using a distributed parameter model," Journal of Power Sources, vol. 165, pp. 152-170, 2007.
    • (2007) Journal of Power Sources , vol.165 , pp. 152-170
    • Methekar, R.N.1    Prasad, V.2    Gudi, R.D.3
  • 12
    • 46449121278 scopus 로고    scopus 로고
    • Performance of a PEM fuel cell water management system using static output feedback
    • New York, USA, paper ThB06.6
    • A. Y. Karnik, J. H. Buckland, and J. Sun, "Performance of a PEM fuel cell water management system using static output feedback," in Proc. 2007 American Control Conference, New York, USA, paper ThB06.6, 2007.
    • (2007) Proc. 2007 American Control Conference
    • Karnik, A.Y.1    Buckland, J.H.2    Sun, J.3
  • 15
    • 33744945065 scopus 로고    scopus 로고
    • Fuel-cell powered uninterruptible power supply systems: Design considerations
    • W. J. Choi, J. W. Howze, and P. Enjeti, "Fuel-cell powered uninterruptible power supply systems: design considerations," Journal of Power Sources, vol. 157, pp. 311-317, 2006.
    • (2006) Journal of Power Sources , vol.157 , pp. 311-317
    • Choi, W.J.1    Howze, J.W.2    Enjeti, P.3
  • 18
    • 40849097471 scopus 로고    scopus 로고
    • Intelligent uninterruptible power supply system with backup fuel cell/battery hybrid power source
    • Y. D. Zhan, Y. G. Guo, J. G. Zhu and H. Wang, "Intelligent uninterruptible power supply system with backup fuel cell/battery hybrid power source," Journal of Power Sources, vol. 179, pp. 745-753, 2008.
    • (2008) Journal of Power Sources , vol.179 , pp. 745-753
    • Zhan, Y.D.1    Guo, Y.G.2    Zhu, J.G.3    Wang, H.4
  • 20
    • 72449128713 scopus 로고    scopus 로고
    • Horizon Technology, 300W Fuel Cell Stack Operating Instruments, www.horizonfuelcell.com.
    • Horizon Technology, 300W Fuel Cell Stack Operating Instruments, www.horizonfuelcell.com.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.