A novel non-invasive method to assess aortic valve opening in HeartMate II left ventricular assist device patients using a modified Karhunen-Loève transformation

Author keywords

aortic valve; automation; HeartMate II; Karhunen Lo ve transform; neurological events; PCA; thrombus formation

Indexed keywords

AORTA VALVE; AORTA VALVE REGURGITATION; ARTICLE; CARDIAC PATIENT; CLINICAL ARTICLE; DISEASE SEVERITY; ECHOCARDIOGRAPHY; ELECTRIC CURRENT; HEART ASSIST DEVICE; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE PRESSURE; HUMAN; NON INVASIVE PROCEDURE; PRINCIPAL COMPONENT ANALYSIS; PRIORITY JOURNAL; WAVEFORM;

EID: 72249111072     PISSN: 10532498     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.healun.2009.08.027     Document Type: Article
Times cited : (20)

References (10)
  • 1
    • 34247885945 scopus 로고    scopus 로고
    • A national survey of the prevalence, incidence, primary care burden and treatment of atrial fibrillation in Scotland
    • Murphy N., Simpson C., Jhund P., et al. A national survey of the prevalence, incidence, primary care burden and treatment of atrial fibrillation in Scotland. Heart 93 (2007) 606-612
    • (2007) Heart , vol.93 , pp. 606-612
    • Murphy, N.1    Simpson, C.2    Jhund, P.3
  • 2
    • 52949120958 scopus 로고    scopus 로고
    • Differences in pulsatile and non-pulsatile mechanical circulatory support in long-term use
    • Drews T., Jurmann M., Michael D., Miralem P., Weng Y., and Hetzer R. Differences in pulsatile and non-pulsatile mechanical circulatory support in long-term use. J Heart Lung Transplant 27 (2008) 1096-1101
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1096-1101
    • Drews, T.1    Jurmann, M.2    Michael, D.3    Miralem, P.4    Weng, Y.5    Hetzer, R.6
  • 3
    • 67349185641 scopus 로고    scopus 로고
    • Assessment of arterial blood pressure during support with an axial flow left ventricular assist device
    • Myers T., Bolmers M., Kar B., and Frazier O. Assessment of arterial blood pressure during support with an axial flow left ventricular assist device. J Heart Lung Transplant 28 (2009) 423-427
    • (2009) J Heart Lung Transplant , vol.28 , pp. 423-427
    • Myers, T.1    Bolmers, M.2    Kar, B.3    Frazier, O.4
  • 4
    • 13844250349 scopus 로고    scopus 로고
    • Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts
    • Rose A., and Park S. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts. Cardiovasc Pathol 14 (2005) 19-23
    • (2005) Cardiovasc Pathol , vol.14 , pp. 19-23
    • Rose, A.1    Park, S.2
  • 6
    • 2342419946 scopus 로고    scopus 로고
    • Left ventricular assist device malfunction: a systematic approach to diagnosis
    • Horton S.C., Khodaverdian R., Powers A., et al. Left ventricular assist device malfunction: a systematic approach to diagnosis. J Am Coll Cardiol 43 (2004) 1574-1583
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1574-1583
    • Horton, S.C.1    Khodaverdian, R.2    Powers, A.3
  • 7
    • 0033786283 scopus 로고    scopus 로고
    • Partial aortic valve fusion induced by left ventricular assist device
    • Rose A.G., Park S.J., Bank A.J., and Miller L.W. Partial aortic valve fusion induced by left ventricular assist device. Ann Thorac Surg 70 (2000) 1270-1274
    • (2000) Ann Thorac Surg , vol.70 , pp. 1270-1274
    • Rose, A.G.1    Park, S.J.2    Bank, A.J.3    Miller, L.W.4
  • 8
    • 2542474026 scopus 로고    scopus 로고
    • Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience
    • Lazar R.M., Shapiro P.A., Jaski B.E., et al. Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience. Circulation 109 (2004) 2423-2427
    • (2004) Circulation , vol.109 , pp. 2423-2427
    • Lazar, R.M.1    Shapiro, P.A.2    Jaski, B.E.3
  • 9
    • 57049163522 scopus 로고    scopus 로고
    • Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device
    • Mudd J.O., Cuda J.D., Halushka M., Soderlund K.A., Conte J.V., and Russell S.D. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. J Heart Lung Transplant 27 (2008) 1269-1274
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1269-1274
    • Mudd, J.O.1    Cuda, J.D.2    Halushka, M.3    Soderlund, K.A.4    Conte, J.V.5    Russell, S.D.6
  • 10
    • 67349185641 scopus 로고    scopus 로고
    • Assessment of arterial blood pressure during support with an axial flow left ventricular assist device
    • Myers T.J., Bolmers M., Gregoric I.D., Kar B., and Frazier O.H. Assessment of arterial blood pressure during support with an axial flow left ventricular assist device. J Heart Lung Transplant 28 (2009) 423-427
    • (2009) J Heart Lung Transplant , vol.28 , pp. 423-427
    • Myers, T.J.1    Bolmers, M.2    Gregoric, I.D.3    Kar, B.4    Frazier, O.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.