Left ventricular assist device malfunction: A systematic approach to diagnosis

Author keywords

heart failure; HF; inflow valve regurgitation; IVR; left ventricle ventricular; left ventricular assist device; LV; LVAD; PCWP; pulmonary capillary wedge pressure; REMATCH

Indexed keywords

ADULT; AGED; AORTA VALVE REGURGITATION; ARTICLE; ARTIFICIAL EMBOLISM; CATHETER; CLINICAL ARTICLE; CLINICAL EXAMINATION; CLINICAL PROTOCOL; DIAGNOSTIC PROCEDURE; DISEASE SEVERITY; EMBOLISM; EVALUATION; FEMALE; HEART ASSIST DEVICE; HEART LEFT VENTRICLE; HUMAN; MALE; MEDICAL DOCUMENTATION; MITRAL VALVE REGURGITATION; PRIORITY JOURNAL; TREATMENT OUTCOME;

EID: 2342419946     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2003.11.055     Document Type: Article
Times cited : (50)

References (11)
  • 1
    • 0029113695 scopus 로고
    • Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system
    • Frazier O.H., Rose E.A., McCarthy P., et al. Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Ann Surg. 222:1995;327-338
    • (1995) Ann Surg , vol.222 , pp. 327-338
    • Frazier, O.H.1    Rose, E.A.2    McCarthy, P.3
  • 2
    • 0033932905 scopus 로고    scopus 로고
    • Effects of left ventricular assist devices on outcomes in patients undergoing heart transplantation
    • Bank A., Sajad H., Nguyen D., et al. Effects of left ventricular assist devices on outcomes in patients undergoing heart transplantation. Ann Thorac Surg. 69:2000;1369-1374
    • (2000) Ann Thorac Surg , vol.69 , pp. 1369-1374
    • Bank, A.1    Sajad, H.2    Nguyen, D.3
  • 3
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • Rose E.A., Gellins A.C., Moskowitz A.J., et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 345:2001;1435-1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gellins, A.C.2    Moskowitz, A.J.3
  • 4
    • 0035169221 scopus 로고    scopus 로고
    • Evaluation of a patient with left ventricular assist device dysfunction
    • Ferns J, Dowling R, Bhat G. Evaluation of a patient with left ventricular assist device dysfunction. ASAIO J 2001:47696-8.
    • (2001) ASAIO J , pp. 47696-47698
    • Ferns, J.1    Dowling, R.2    Bhat, G.3
  • 5
    • 0031941849 scopus 로고    scopus 로고
    • Gleoroscopy and selective angiography of left ventricular assist system inflow cannula as a method of detecting cannula entrapment
    • Park M.H., Gourdrea E., Tolman T.E., Vetrovec G.W., Guerraty A. Gleoroscopy and selective angiography of left ventricular assist system inflow cannula as a method of detecting cannula entrapment. Cathet Cardiovasc Diagn. 44:1998;47-51
    • (1998) Cathet Cardiovasc Diagn , vol.44 , pp. 47-51
    • Park, M.H.1    Gourdrea, E.2    Tolman, T.E.3    Vetrovec, G.W.4    Guerraty, A.5
  • 6
    • 2342423340 scopus 로고    scopus 로고
    • Transthoracic echocardiography in routine assessment of vented electric HeartMate left ventricular assist device function
    • (abstr)
    • Horton S.C., McIntosh M.L., Khodaverdian R.A., Chatelain P.F., Horne B.D., Long J.W. Transthoracic echocardiography in routine assessment of vented electric HeartMate left ventricular assist device function. (abstr) J Am Soc Echocardiogr. 15:2002;507
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 507
    • Horton, S.C.1    McIntosh, M.L.2    Khodaverdian, R.A.3    Chatelain, P.F.4    Horne, B.D.5    Long, J.W.6
  • 8
    • 2342422132 scopus 로고    scopus 로고
    • Transthoracic echocardiographic characteristics of the HeartMate left ventricular assist device inflow valve dysfunction
    • (abstr)
    • Khodaverdian R.A., Chatelain P.F., Horton S.C., et al. Transthoracic echocardiographic characteristics of the HeartMate left ventricular assist device inflow valve dysfunction. (abstr) J Am Soc Echocardiogr. 15:2002;508
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 508
    • Khodaverdian, R.A.1    Chatelain, P.F.2    Horton, S.C.3
  • 9
    • 0033786283 scopus 로고    scopus 로고
    • Partial aortic valve fusion induced by left ventricular assist device
    • Rose A.G., Park S.J., Bank A.J., Miller L.W. Partial aortic valve fusion induced by left ventricular assist device. Ann Thorac Surg. 70:2000;1270-1274
    • (2000) Ann Thorac Surg , vol.70 , pp. 1270-1274
    • Rose, A.G.1    Park, S.J.2    Bank, A.J.3    Miller, L.W.4
  • 10
    • 0035437458 scopus 로고    scopus 로고
    • Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns
    • Samuels L.E., Thomas M.P., Holmes E.C., et al. Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system Signs, symptoms, and concerns. J Thorac Cardiovasc Surg. 122:2001;380-381
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 380-381
    • Samuels, L.E.1    Thomas, M.P.2    Holmes, E.C.3
  • 11
    • 0032547931 scopus 로고    scopus 로고
    • Implantable left ventricular assist devices
    • Goldstein D.J., Mehmet C.O., Rose E.A. Implantable left ventricular assist devices. N Engl J Med. 339:1998;1522-1533
    • (1998) N Engl J Med , vol.339 , pp. 1522-1533
    • Goldstein, D.J.1    Mehmet, C.O.2    Rose, E.A.3