메뉴 건너뛰기




Volumn 17, Issue 25, 2009, Pages 22320-22332

High throughput transmission optical projection tomography using low cost graphics processing unit

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER GRAPHICS; COMPUTER GRAPHICS EQUIPMENT; DATA HANDLING; IMAGE PROCESSING; LIGHT TRANSMISSION; OPTICAL PROJECTORS; PROGRAM PROCESSORS; THROUGHPUT; TOMOGRAPHY;

EID: 72049128923     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.17.022320     Document Type: Article
Times cited : (27)

References (28)
  • 1
    • 21444441373 scopus 로고    scopus 로고
    • Looking and listening to light: The evolution of whole-body photonic imaging
    • V. Ntziachristos, J. Ripoll, L. V. Wang, and R. Weissleder, "Looking and listening to light: the evolution of whole-body photonic imaging," Nat. Biotechnol. 23(3), 313-320 (2005).
    • (2005) Nat. Biotechnol. , vol.23 , Issue.3 , pp. 313-320
    • Ntziachristos, V.1    Ripoll, J.2    Wang, L.V.3    Weissleder, R.4
  • 3
    • 37749036012 scopus 로고    scopus 로고
    • In vivo imaging of Drosophila melanogaster pupae with mesoscopic fluorescence tomography
    • C. Vinegoni, C. Pitsouli, D. Razansky, N. Perrimon, and V. Ntziachristos, "In vivo imaging of Drosophila melanogaster pupae with mesoscopic fluorescence tomography," Nat. Methods 5(1), 45-47 (2007).
    • (2007) Nat. Methods , vol.5 , Issue.1 , pp. 45-47
    • Vinegoni, C.1    Pitsouli, C.2    Razansky, D.3    Perrimon, N.4    Ntziachristos, V.5
  • 5
    • 37549056236 scopus 로고    scopus 로고
    • Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation
    • H. S. Sakhalkar, and M. Oldham, "Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation," Med. Phys. 35(1), 101-111 (2008).
    • (2008) Med. Phys. , vol.35 , Issue.1 , pp. 101-111
    • Sakhalkar, H.S.1    Oldham, M.2
  • 6
    • 0001169360 scopus 로고
    • On the determination of function from their integrals along certain manifolds
    • J. Radon, "On the determination of function from their integrals along certain manifolds," Ber. Saechs. Akad. Wiss, Leipzig Math. Phys. Kl. 69, 262-277 (1917).
    • (1917) Ber. Saechs. Akad. Wiss, Leipzig Math. Phys. Kl. , vol.69 , pp. 262-277
    • Radon, J.1
  • 7
    • 0016117351 scopus 로고
    • Digital reconstruction of multidimensional signals from their projections
    • R. M. Mersereau, and A. V. Oppenheim, "Digital reconstruction of multidimensional signals from their projections," Proc. IEEE 62(10), 1319-1338 (1974).
    • (1974) Proc. IEEE , vol.62 , Issue.10 , pp. 1319-1338
    • Mersereau, R.M.1    Oppenheim, A.V.2
  • 8
    • 0017005468 scopus 로고
    • Direct Fourier transform techniques in 3-D image reconstruction
    • R. M. Mersereau, "Direct Fourier transform techniques in 3-D image reconstruction," Comput. Biol. Med. 6(4), 247-258 (1976).
    • (1976) Comput. Biol. Med. , vol.6 , Issue.4 , pp. 247-258
    • Mersereau, R.M.1
  • 9
    • 0019732771 scopus 로고
    • An investigation of computerized tomography by direct Fourier inversion and optimum interpolation
    • H. Stark, J. W. Woods, I. Paul, and R. Hingorani, "An investigation of computerized tomography by direct Fourier inversion and optimum interpolation," IEEE Trans. Biomed. Eng. 28(7), 496-505 (1981).
    • (1981) IEEE Trans. Biomed. Eng. , vol.28 , Issue.7 , pp. 496-505
    • Stark, H.1    Woods, J.W.2    Paul, I.3    Hingorani, R.4
  • 10
    • 0020721968 scopus 로고
    • Reconstruction algorithms: Transform methods
    • R. M. Lewitt, "Reconstruction algorithms: Transform methods," Proc. IEEE 71(3), 390-408 (1983).
    • (1983) Proc. IEEE , vol.71 , Issue.3 , pp. 390-408
    • Lewitt, R.M.1
  • 11
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for fourier inversion in computer tomography
    • J. D. O?Sullivan, "A fast sinc function gridding algorithm for fourier inversion in computer tomography," IEEE Trans. Med. Imaging 4(4), 200-207 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.4 , Issue.4 , pp. 200-207
    • O'sullivan, J.D.1
  • 12
    • 0025628651 scopus 로고
    • A high-speed reconstruction from projections using direct Fourier method with optimized parameters-an experimental analysis
    • S. Matej, and I. Bajla, "A high-speed reconstruction from projections using direct Fourier method with optimized parameters-an experimental analysis," IEEE Trans. Med. Imaging 9(4), 421-429 (1990).
    • (1990) IEEE Trans. Med. Imaging , vol.9 , Issue.4 , pp. 421-429
    • Matej, S.1    Bajla, I.2
  • 13
    • 0029378348 scopus 로고
    • The gridding method for image reconstruction by Fourier transformation
    • H. Schomberg, and J. Timmer, "The gridding method for image reconstruction by Fourier transformation," IEEE Trans. Med. Imaging 14(3), 596-607 (1995).
    • (1995) IEEE Trans. Med. Imaging , vol.14 , Issue.3 , pp. 596-607
    • Schomberg, H.1    Timmer, J.2
  • 14
    • 0034566367 scopus 로고    scopus 로고
    • A fast and accurate multilevel inversion of the radon transform
    • A. Brandt, J. Mann, M. Brodski, and M. Galun, "A fast and accurate multilevel inversion of the radon transform," SIAM J. Appl. Math. 60(2), 437-462 (2000).
    • (2000) SIAM J. Appl. Math. , vol.60 , Issue.2 , pp. 437-462
    • Brandt, A.1    Mann, J.2    Brodski, M.3    Galun, M.4
  • 15
    • 0034298607 scopus 로고    scopus 로고
    • O(N(2)log(2)N) filtered backprojection reconstruction algorithm for tomography
    • S. Basu, and Y. Bresler, "O(N(2)log(2)N) filtered backprojection reconstruction algorithm for tomography," IEEE Trans. Image Process. 9(10), 1760-1773 (2000).
    • (2000) IEEE Trans. Image Process. , vol.9 , Issue.10 , pp. 1760-1773
    • Basu, S.1    Bresler, Y.2
  • 16
    • 34748901307 scopus 로고    scopus 로고
    • GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration
    • G. C. Sharp, N. Kandasamy, H. Singh, and M. Folkert, "GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration," Phys. Med. Biol. 52(19), 5771-5783 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , Issue.19 , pp. 5771-5783
    • Sharp, G.C.1    Kandasamy, N.2    Singh, H.3    Folkert, M.4
  • 17
    • 49149110166 scopus 로고    scopus 로고
    • Real-time digital holographic microscopy using the graphic processing unit
    • T. Shimobaba, Y. Sato, J. Miura, M. Takenouchi, and T. Ito, "Real-time digital holographic microscopy using the graphic processing unit," Opt. Express 16(16), 11776-11781 (2008).
    • (2008) Opt. Express , vol.16 , Issue.16 , pp. 11776-11781
    • Shimobaba, T.1    Sato, Y.2    Miura, J.3    Takenouchi, M.4    Ito, T.5
  • 18
    • 72049116012 scopus 로고    scopus 로고
    • Why do GPUs work so well for acceleration of CT?
    • Keynote, Computational Imaging V, San Jose
    • K. Mueller, F. Xu, and N. Neophytou, "Why do GPUs work so well for acceleration of CT? SPIE Electronic Imaging '07," Keynote, Computational Imaging V, San Jose, (2007).
    • (2007) SPIE Electronic Imaging '07
    • Mueller, K.1    Xu, F.2    Neophytou, N.3
  • 21
    • 0032298134 scopus 로고    scopus 로고
    • Data-parallel tomographyc reconstruction: A comparison of filtered backprojection and direct fourier reconstruction
    • J. B. T. M. Roerdink, and M. A. Westenbrg, "Data-parallel tomographyc reconstruction: a comparison of filtered backprojection and direct fourier reconstruction," Parallel Comput. 24(14), 2129-2142 (1998).
    • (1998) Parallel Comput. , vol.24 , Issue.14 , pp. 2129-2142
    • Roerdink, J.B.T.M.1    Westenbrg, M.A.2
  • 24
    • 43449128019 scopus 로고    scopus 로고
    • NVIDIA CUDA software and GPU parallel computing architecture
    • J. Nickolls and I. Buck, "NVIDIA CUDA software and GPU parallel computing architecture," Microprocessor Forum, May (2007).
    • (2007) Microprocessor Forum, May
    • Nickolls, J.1    Buck, I.2
  • 28
    • 34248178543 scopus 로고    scopus 로고
    • Resolution improvement in emission optical projection tomography
    • J. R. Walls, J. G. Sled, J. Sharpe, and R. M. Henkelman, "Resolution improvement in emission optical projection tomography," Phys. Med. Biol. 52(10), 2775-2790 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , Issue.10 , pp. 2775-2790
    • Walls, J.R.1    Sled, J.G.2    Sharpe, J.3    Henkelman, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.