메뉴 건너뛰기




Volumn 21, Issue 8-9, 2009, Pages 191-194

Lipid analysis via HPLC with a charged aerosol detector

Author keywords

[No Author keywords available]

Indexed keywords

AEROSOL PARTICLES; CHARGED AEROSOLS; COLUMN EFFLUENT; DETECTION METHODS; EVAPORATIVE LIGHT SCATTERING DETECTORS; FATTY ACID METHYL ESTER; FLAME IONIZATION DETECTORS; FREE FATTY ACID; LIPID ANALYSIS; LIPID EXTRACT; QUANTITATIVE ANALYSIS; UNSATURATED MOLECULES;

EID: 72049118864     PISSN: 0956666X     EISSN: 18635377     Source Type: Journal    
DOI: 10.1002/lite.200900048     Document Type: Article
Times cited : (23)

References (6)
  • 1
    • 33749835284 scopus 로고    scopus 로고
    • The evaporative light-scattering detector as a tool for the analysis of lipids by HPLC
    • eds. Lin, J.-T. and McKeon, T.A., H.N.B. Publishing, New York
    • Moreau, R.A. (2005) The evaporative light-scattering detector as a tool for the analysis of lipids by HPLC, in HPLC of Acyl Lipids, eds. Lin, J.-T. and McKeon, T.A., H.N.B. Publishing, New York, pp. 93-116.
    • (2005) HPLC of Acyl Lipids , pp. 93-116
    • Moreau, R.A.1
  • 2
    • 33749647656 scopus 로고    scopus 로고
    • The quantitative analysis of lipids via HPLC with a charged aerosol detector
    • Moreau, R.A. (2006) The quantitative analysis of lipids via HPLC with a charged aerosol detector Lipids, 41, 727-734.
    • (2006) Lipids , vol.41 , pp. 727-734
    • Moreau, R.A.1
  • 3
    • 74949125471 scopus 로고    scopus 로고
    • The use of charged aerosol detection with HPLC for the measurement of lipids, in Lipidomics
    • ed. D. Armstrong, Humana Press, 2009, in press
    • Plante, M. et al. (2009) The use of charged aerosol detection with HPLC for the measurement of lipids, in Lipidomics, Methods in Molecular Biology, vol 579, ed. D. Armstrong, Humana Press, 2009, in press.
    • (2009) Methods in Molecular Biology , pp. 579
    • Plante, M.1
  • 4
    • 53749096621 scopus 로고    scopus 로고
    • Comparison between charged aerosol detection and light scattering detection for the analysis of Leishmania membrane phospholipids
    • Godoy Ramos, R. (2008) Comparison between charged aerosol detection and light scattering detection for the analysis of Leishmania membrane phospholipids. J. Chromatogr., 1209, 88-94.
    • (2008) J. Chromatogr. , vol.1209 , pp. 88-94
    • Godoy Ramos, R.1
  • 5
    • 58149114550 scopus 로고    scopus 로고
    • Simple and precise detection of lipid compounds present within liposomal formulations using a charged aerosol detector
    • Schönherr, C. et al. (2009) Simple and precise detection of lipid compounds present within liposomal formulations using a charged aerosol detector. J. Chromatogr. A, 1216, 781-786.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 781-786
    • Schönherr, C.1
  • 6
    • 36549076436 scopus 로고    scopus 로고
    • Quantitation of triacylglycerols from plant oils using charged aerosol detection with gradient compensation
    • Lísa, M., et al. (2007) Quantitation of triacylglycerols from plant oils using charged aerosol detection with gradient compensation. J. Chromatogr. A, 1176, 135-142.
    • (2007) J. Chromatogr. A , vol.1176 , pp. 135-142
    • Lísa, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.