메뉴 건너뛰기




Volumn 33, Issue 4, 2009, Pages 368-377

Successful preliminary walking experiments on a transtibial amputee fitted with a powered prosthesis

Author keywords

Amputee; Gait analysis; Powered; Prosthetic design; Prosthetic feet; Rehabilitation; Stiffness; Torque

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CONTROLLED STUDY; DEVICE; DISABLED PERSON; HUMAN; LEG AMPUTATION; MALE; PLEATED PNEUMATIC ARTIFICIAL MUSCLE; POWERED TRANSTIBIAL PROSTHESIS; PROSTHESIS; RIGIDITY; TIBIA; TORQUE; WALKING SPEED;

EID: 72049105596     PISSN: 03093646     EISSN: 17461553     Source Type: Journal    
DOI: 10.3109/03093640902984587     Document Type: Article
Times cited : (20)

References (18)
  • 1
    • 0027364958 scopus 로고
    • Efficiency of dynamic elastic response prosthetic feet
    • Perry J, Shanfield S. Efficiency of dynamic elastic response prosthetic feet. J Rehabil Res Develop 1993;30(1):137-143.
    • (1993) J Rehabil Res Develop , vol.30 , Issue.1 , pp. 137-143
    • Perry, J.1    Shanfield, S.2
  • 2
    • 0031440840 scopus 로고    scopus 로고
    • Prosthetic weight acceptance mechanics in trans-tibial amputees wearing the Single Axis, Seattle Lite, and Flex Foot
    • Perry J, Boyd L, Sreesha SR, Mulroy SJ. Prosthetic weight acceptance mechanics in trans-tibial amputees wearing the Single Axis, Seattle Lite, and Flex Foot. IEEE Transact Rehabil Engineering 1997;5(4):283-289.
    • (1997) IEEE Transact Rehabil Engineering , vol.5 , Issue.4 , pp. 283-289
    • Perry, J.1    Boyd, L.2    Sreesha, S.R.3    Mulroy, S.J.4
  • 3
    • 0026775785 scopus 로고
    • Analysis of mechanical and metabolic factors in the gait of congenital below knee amputees. A comparison of the SACH and Seattle feet
    • Colborne GR, Naumann S, Longmuir PE, Berbrayer D. Analysis of mechanical and metabolic factors in the gait of congenital below knee amputees. A comparison of the SACH and Seattle feet. Am J Phys Med Rehabil 1992;71(5):272-278.
    • (1992) Am J Phys Med Rehabil , vol.71 , Issue.5 , pp. 272-278
    • Colborne, G.R.1    Naumann, S.2    Longmuir, P.E.3    Berbrayer, D.4
  • 10
    • 33745366113 scopus 로고    scopus 로고
    • Mechanical performance of artificial pneumatic muscles to power an ankle foot orthosis
    • Gordon KE, Sawicki GS, Ferris DP. Mechanical performance of artificial pneumatic muscles to power an ankle foot orthosis. J Biomechanics 2006;39:1832-1841.
    • (2006) J Biomechanics , vol.39 , pp. 1832-1841
    • Gordon, K.E.1    Sawicki, G.S.2    Ferris, D.P.3
  • 11
    • 84978749359 scopus 로고    scopus 로고
    • The concept and design of pleated pneumatic artificial muscles
    • Daerden F, Lefeber D. The concept and design of pleated pneumatic artificial muscles. Int J Fluid Power 2001;2(3):41-50.
    • (2001) Int J Fluid Power , vol.2 , Issue.3 , pp. 41-50
    • Daerden, F.1    Lefeber, D.2
  • 12
    • 0022399788 scopus 로고
    • Prosthetic rehabilitation of geriatric amputee patients: A follow up study
    • Steinberg FU, Sunwoo I, Roettger RF. Prosthetic rehabilitation of geriatric amputee patients: A follow up study. Arch Phys Med Rehabil 1985;66:742-745.
    • (1985) Arch Phys Med Rehabil , vol.66 , pp. 742-745
    • Steinberg, F.U.1    Sunwoo, I.2    Roettger, R.F.3
  • 13
    • 17044430593 scopus 로고    scopus 로고
    • Exploiting adaptable passive behaviour to influence natural dynamics applied to legged robots
    • Verrelst B, Van Ham R, Vanderborght B, Vermeulen J, Lefeber D, Daerden F. Exploiting adaptable passive behaviour to influence natural dynamics applied to legged robots. Robotica 2005;23(2):149-158.
    • (2005) Robotica , vol.23 , Issue.2 , pp. 149-158
    • Verrelst, B.1    Van Ham, R.2    Vanderborght, B.3    Vermeulen, J.4    Lefeber, D.5    Daerden, F.6
  • 15
    • 4344701495 scopus 로고    scopus 로고
    • The human ankle during walking: Implications for design of biomimetic ankle prostheses
    • Hansen AH, Childress DS, Miff SC, Gard SA, Mesplay KP. The human ankle during walking: Implications for design of biomimetic ankle prostheses. J Biomechanics 2004;37:1467-1474.
    • (2004) J Biomechanics , vol.37 , pp. 1467-1474
    • Hansen, A.H.1    Childress, D.S.2    Miff, S.C.3    Gard, S.A.4    Mesplay, K.P.5
  • 16
    • 0344466111 scopus 로고
    • Gait analysis: Normal and pathological function. ISBN 1-55642-192-3
    • Perry J. Gait analysis: Normal and pathological function. ISBN 1-55642-192-3. Slack Incorporated. 1992.
    • (1992) Slack Incorporated
    • Perry, J.1
  • 17
    • 33645830524 scopus 로고    scopus 로고
    • Design and energetic characterization of a proportional-injector monopropellant-powered actuator
    • Fite KB, Goldfarb M. Design and energetic characterization of a proportional-injector monopropellant-powered actuator. IEEE/ASME Transact Mechatronics 2006;11(2):196-204.
    • (2006) IEEE/ASME Transact Mechatronics , vol.11 , Issue.2 , pp. 196-204
    • Fite, K.B.1    Goldfarb, M.2
  • 18
    • 33947138101 scopus 로고    scopus 로고
    • Design, control, and energetic characterization of a solenoid injected monopropellant powered actuator
    • Shields BL, Fite K, Goldfarb M. Design, control, and energetic characterization of a solenoid injected monopropellant powered actuator. IEEE/ASME Transact Mechatronics 2006;11(4):477-487.
    • (2006) IEEE/ASME Transact Mechatronics , vol.11 , Issue.4 , pp. 477-487
    • Shields, B.L.1    Fite, K.2    Goldfarb, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.