-
1
-
-
0141831249
-
Accuracy of implant placement with a stereolithographic surgical guide
-
Sarment D.P., Sukovic P., and Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide. Oral Maxillofac Implants 18 (2003) 571-577
-
(2003)
Oral Maxillofac Implants
, vol.18
, pp. 571-577
-
-
Sarment, D.P.1
Sukovic, P.2
Clinthorne, N.3
-
2
-
-
0141575639
-
Predictable implant placement with a diagnostic surgical template and advanced radiographic imaging
-
Kopp K.C., Koslow A.H., and Abdo O.S. Predictable implant placement with a diagnostic surgical template and advanced radiographic imaging. J Prosthet Dent 89 (2003) 611-615
-
(2003)
J Prosthet Dent
, vol.89
, pp. 611-615
-
-
Kopp, K.C.1
Koslow, A.H.2
Abdo, O.S.3
-
3
-
-
0041510493
-
Stereolithographic surgical templates for placement of Dental Implants in complex cases
-
Sarment D.P., Al-shammari K., and Kazor C. Stereolithographic surgical templates for placement of Dental Implants in complex cases. Int J Periodontics Restorative Dent 23 (2003) 287-295
-
(2003)
Int J Periodontics Restorative Dent
, vol.23
, pp. 287-295
-
-
Sarment, D.P.1
Al-shammari, K.2
Kazor, C.3
-
5
-
-
0032150743
-
Sensory disturbances associated with implant surgery
-
Dao T.T., and Mellor A. Sensory disturbances associated with implant surgery. Int J Prosthodont 11 (1998) 462-469
-
(1998)
Int J Prosthodont
, vol.11
, pp. 462-469
-
-
Dao, T.T.1
Mellor, A.2
-
6
-
-
0034170227
-
Altered sensation associated with implants in the anterior mandible: a prospective study
-
Walton J.N. Altered sensation associated with implants in the anterior mandible: a prospective study. J Prosthet Dent 83 (2000) 443-449
-
(2000)
J Prosthet Dent
, vol.83
, pp. 443-449
-
-
Walton, J.N.1
-
7
-
-
0033129920
-
Assessment of the blood supply to the mental region for reduction of bleeding complications during implant surgery in the interforaminal region
-
Hofschneider U., Tepper G., Gahleitner A., and Ulm C. Assessment of the blood supply to the mental region for reduction of bleeding complications during implant surgery in the interforaminal region. Int J Oral Maxillofac Implants 14 (1999) 379-383
-
(1999)
Int J Oral Maxillofac Implants
, vol.14
, pp. 379-383
-
-
Hofschneider, U.1
Tepper, G.2
Gahleitner, A.3
Ulm, C.4
-
8
-
-
0035234320
-
Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complication during implant surgery
-
Tepper G., Hofschneider U.B., Gahleitner A., and Ulm C. Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complication during implant surgery. Int J Oral Maxillofac Implants 16 (2001) 68-72
-
(2001)
Int J Oral Maxillofac Implants
, vol.16
, pp. 68-72
-
-
Tepper, G.1
Hofschneider, U.B.2
Gahleitner, A.3
Ulm, C.4
-
10
-
-
0036364616
-
The use of computerized tomography for diagnosis and treatment planning in implant dentistry
-
Iplikcioglu H., Akca K., and Cehreli M.C. The use of computerized tomography for diagnosis and treatment planning in implant dentistry. J Oral Implantol 28 (2002) 29-35
-
(2002)
J Oral Implantol
, vol.28
, pp. 29-35
-
-
Iplikcioglu, H.1
Akca, K.2
Cehreli, M.C.3
-
11
-
-
0642312660
-
An illustrative study of the role of tomograms for the placement of dental implants
-
Thunthy K.H., Yeadon W.R., and Nasr H.F. An illustrative study of the role of tomograms for the placement of dental implants. J Oral Implantol 29 (2003) 91-95
-
(2003)
J Oral Implantol
, vol.29
, pp. 91-95
-
-
Thunthy, K.H.1
Yeadon, W.R.2
Nasr, H.F.3
-
12
-
-
0038079812
-
Dental CT: imaging technique, anatomy, and pathologic conditions of the jaws
-
Gahleitner A., Watzek G., and Imhof H. Dental CT: imaging technique, anatomy, and pathologic conditions of the jaws. Eur Radiol 13 (2003) 366-376
-
(2003)
Eur Radiol
, vol.13
, pp. 366-376
-
-
Gahleitner, A.1
Watzek, G.2
Imhof, H.3
-
13
-
-
0034164598
-
Three-dimensional computed tomography imaging in dentistry
-
Kawamata A., Ariji Y., and Langlais R.P. Three-dimensional computed tomography imaging in dentistry. Dent Clin North Am 44 (2000) 395-410
-
(2000)
Dent Clin North Am
, vol.44
, pp. 395-410
-
-
Kawamata, A.1
Ariji, Y.2
Langlais, R.P.3
-
14
-
-
0642273266
-
Craniofacial computed tomography scanning: technology, applications and future trends
-
discussion 179-182.
-
Vannier M.W. Craniofacial computed tomography scanning: technology, applications and future trends. Orthod Craniofac Res 1 (2003) 23-30 discussion 179-182.
-
(2003)
Orthod Craniofac Res
, vol.1
, pp. 23-30
-
-
Vannier, M.W.1
-
15
-
-
33644639722
-
Clinical applications of cone beam computed tomography in dental practice
-
Scarfe W.C., Farman A.G., and Sukovic P. Clinical applications of cone beam computed tomography in dental practice. J Can Dent Assoc 72 (2006) 75-80
-
(2006)
J Can Dent Assoc
, vol.72
, pp. 75-80
-
-
Scarfe, W.C.1
Farman, A.G.2
Sukovic, P.3
-
17
-
-
33845385796
-
Accuracy of three-dimensional measurements using cone-beam CT
-
Pinsky H.M., Dyda S., Pinsky R.W., Misch K.A., and Sarment D.P. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofac Radiol 35 (2006) 410-416
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 410-416
-
-
Pinsky, H.M.1
Dyda, S.2
Pinsky, R.W.3
Misch, K.A.4
Sarment, D.P.5
-
18
-
-
3042557818
-
Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: case reports
-
Sato S., Arai Y., Shinoda K., and Ito K. Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: case reports. Quintessence Int 35 (2004) 525-528
-
(2004)
Quintessence Int
, vol.35
, pp. 525-528
-
-
Sato, S.1
Arai, Y.2
Shinoda, K.3
Ito, K.4
-
19
-
-
64549109838
-
Evaluation of voxel values in mandibular cancellous bone: relationship between cone-beam computed tomography and multislice helical computed tomography
-
Naitoh M., Hirukawa A., Katsumata A., and Ariji E. Evaluation of voxel values in mandibular cancellous bone: relationship between cone-beam computed tomography and multislice helical computed tomography. Clin Oral Implants Res 20 (2009) 503-506
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 503-506
-
-
Naitoh, M.1
Hirukawa, A.2
Katsumata, A.3
Ariji, E.4
-
20
-
-
0034168579
-
Diagnostic imaging with newly developed ortho cubic super-high resolution computed tomography (Ortho-CT)
-
Terakado M., Hashimoto K., Arai Y., Honda M., Sekiwa T., and Sato H. Diagnostic imaging with newly developed ortho cubic super-high resolution computed tomography (Ortho-CT). Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89 (2000) 509-518
-
(2000)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.89
, pp. 509-518
-
-
Terakado, M.1
Hashimoto, K.2
Arai, Y.3
Honda, M.4
Sekiwa, T.5
Sato, H.6
-
21
-
-
0038755182
-
A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine
-
Hashimoto K., Arai Y., Iwai K., Araki M., Kawashima S., and Terakado M. A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95 (2003) 371-377
-
(2003)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.95
, pp. 371-377
-
-
Hashimoto, K.1
Arai, Y.2
Iwai, K.3
Araki, M.4
Kawashima, S.5
Terakado, M.6
-
22
-
-
72049113717
-
Study of the fovea submandibularis during pre-implant diagnostics
-
Jung T. Study of the fovea submandibularis during pre-implant diagnostics. J Friadent Implant 1 (2004) 34-37
-
(2004)
J Friadent Implant
, vol.1
, pp. 34-37
-
-
Jung, T.1
-
24
-
-
1342327951
-
Sublingual hematoma formation during immediate placement of mandibular endosseous implants
-
Isaacson T.J. Sublingual hematoma formation during immediate placement of mandibular endosseous implants. J Am Dent Assoc 135 (2004) 566
-
(2004)
J Am Dent Assoc
, vol.135
, pp. 566
-
-
Isaacson, T.J.1
-
25
-
-
0034573072
-
Emergency tracheostomy following life-threatening hemorrhage in the floor of the mouth during immediate implant placement in the mandibular canine region
-
Givol N., Chaushu G., Halamish-Shani T., and Taicher S. Emergency tracheostomy following life-threatening hemorrhage in the floor of the mouth during immediate implant placement in the mandibular canine region. J Periodontol 71 (2000) 1893-1895
-
(2000)
J Periodontol
, vol.71
, pp. 1893-1895
-
-
Givol, N.1
Chaushu, G.2
Halamish-Shani, T.3
Taicher, S.4
-
26
-
-
0041380916
-
Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas
-
Quirynen M., Mraiwa N., Van Seenberghe D., and Jacobs R. Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas. Clin Oral Implants Res 14 (2003) 280-285
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 280-285
-
-
Quirynen, M.1
Mraiwa, N.2
Van Seenberghe, D.3
Jacobs, R.4
-
27
-
-
0033255437
-
Conventional spiral and low-dose computed mandibular tomography for dental implant planning
-
Ekestubbe A. Conventional spiral and low-dose computed mandibular tomography for dental implant planning. Swed Dent J Suppl 138 (1999) 1-82
-
(1999)
Swed Dent J Suppl
, vol.138
, pp. 1-82
-
-
Ekestubbe, A.1
-
28
-
-
33749385433
-
Intraoperative cone-beam CT for guidance of head and neck surgery: assessment of dose and image quality using a C-arm prototype
-
Daly M.J., Siewerdsen J.H., Moseley D.J., Jaffray D.A., and Irish J.C. Intraoperative cone-beam CT for guidance of head and neck surgery: assessment of dose and image quality using a C-arm prototype. Med Phys 33 (2006) 3767-3780
-
(2006)
Med Phys
, vol.33
, pp. 3767-3780
-
-
Daly, M.J.1
Siewerdsen, J.H.2
Moseley, D.J.3
Jaffray, D.A.4
Irish, J.C.5
|